Automatic Low Temperature ViscoMeter

The automatic low-temperature viscometer maintains a temperature range from -40℃ to room temperature through its sample cell temperature control system. It measures fluid resistance as the rotor rotates and converts this into viscosity values. It is used for testing the flow characteristics of coatings and inks in low-temperature environments, providing guidance for winter construction and the setting of storage and transportation conditions.
Selection
When selecting, ensure the temperature range covers the actual usage environment, measurement accuracy meets process requirements, and sample volume is compatible with common containers. Focus on temperature control stability and ease of calibration, ensure the operation interface is clear and easy to read, and consider the equipment size in relation to laboratory space.

Terms

Standards

Instruments

Measurement accuracy of 0.1 ℃, range of 0~ 100 ℃, real-time display of temperature values, suitable for a variety of Viscometer models, to ensure a stable test environment.

$ 135.00

Microcomputer drive technology and imported stepper motor to ensure smooth speed, measurement accuracy of +/- 1% F. S, repRoducibility +/- 0.5% F. S, with automatic scanning function to help choose the right Rotor speed, with ultra-low viscosity adapter to support viscosity measurement as low as 1cP.

$ 659.00

The maintenance-free pressure pump is resistant to fiber metal particles, supports domestic circulation with sample Cup bracket and external circulation Viscometer jacket thermostatic, temperature control accuracy +/- 0.01 ℃ and low liquid level protection function.

$ 2087.00

Adopt stepper motor direct drive to ensure accurate speed, equipped with RTD temperature probe real-time monitoring, Measurement accuracy of +/- 1% F. S, with ultra-low viscosity adapter to extend Measurement range to 1mPa · s.

$ 1075.00

Adapt to a variety of Viscometer use, suitable for factory field applications, real-time printing measurement results, no need to hand copy, easy operation, can save labor time.

$ 183.00

Adopt imported stepper motor to ensure smooth speed, measurement accuracy of +/- 1% F.S, repRoducibility of +/- 0.5% F.S., support automatic scanning function to help select the appropriate Rotor speed, suitable for accurate measurement of low viscosity fluids.

$ 620.00

Microcomputer PID temperature control technology, Temperature Fluctuation +/- 0.05 ℃, equipped with a 70 opening easy to beaker fixed, fully enclosed Compressor refrigeration fast and stable, 304 stainless steel corrosion resistant and durable.

$ 922.00

Automatic lifting design simplifies operation, no weight measurement, accuracy of +/- 1.5% F.S, Repeatability +/- 1.5% F.S, support KU, g, cP multi-unit display and temperature monitoring.

$ 1074.00

The test program can be uploaded to the Viscometer host, the analysis record data can be collected, the rheological Linear dispersion and Excel can be generated, and five sets of data can be plotted and compared at the same time.

$ 204.00

Adopt binary cascade refrigeration mode to achieve -40 ℃ low temperature control, Temperature Uniformity ≤ 2.0 ℃, equipped with mirror stainless steel inner wall and automatic energy-saving working condition adjustment system, to meet the standard environmental testing requirements.

$ 7219.00

Using stepper motor direct drive to ensure accurate speed, Measurement range 1~ 2000000mPa · s, with RS232 interface and RTD temperature probe, support ultra low viscosity liquid measurement.

$ 1180.00

Using photoelectric detection and automatic dial display, the measurement range is +/- 45 °, the minimum reading is 0.001 °, and the low optical rotation sample can be accurately analyzed, and the operation is simple.

$ 1380.00

Adopt two-stage Compressor cascade refrigeration technology implementation -40 ℃ low temperature, PID temperature control with proportional refrigeration technology to improve the temperature Stability to +/- 0.5 ℃, DC brushless motor supports 100-1200RPM stepless speed regulation, with a variety of alarm and automatic recovery function.

$ 1805.00

Using microcomputer drive technology and imported stepper motor, Measurement accuracy +/- 1% F.S, repRoducibility +/- 0.5% F.S, with automatic scanning function and RS232 interface, support real-time temperature measurement.

$ 527.00

Silicone oil standard solution, calibrated viscosity 380cp, capacity 400ml, suitable for Viscometer calibrating.

$ 185.00

Articles

The main difference between the high-low temperature test chamber and the constant temperature and humidity test chamber
This article mainly distinguishes between high-low temperature test chambers and constant temperature and humidity test chambers.
How to choose the right rotational viscometer?
This article introduces how to select an appropriate rotational viscometer, so you won't be blind when choosing a viscosity measurement instrument!
Stormer viscometer controls the in-can viscosity of latex paint.
This paper introduces the application of the Stormer viscometer in controlling the paint can viscosity of latex paint. Paint can viscosity affects application performance and user experience, with either too high or too low values causing issues.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.