Through-Coating Thickness Gauge

The through-coating thickness gauge operates on the principles of magnetic induction or eddy currents. When the probe contacts the coating, it calculates the thickness based on changes in the magnetic field or variations in eddy current intensity caused by the underlying metal. It is used to measure the thickness of non-conductive coatings or non-ferrous metal coatings on metal substrates, ensuring coating uniformity in quality inspections for industries such as automotive and home appliances.
Selection
When selecting, consider the substrate type: use magnetic induction for ferrous substrates and eddy current for non-ferrous substrates. The measurement range should cover common coating thicknesses, with accuracy meeting the ±1-3% requirement. The probe size should adapt to the shape of the workpiece, with small probes chosen for curved surfaces. The instrument must include calibration functionality and be suitable for the temperature and humidity conditions of the production environment.

Terms

Standards

Instruments

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

Measurement accuracy with professional calibrating services for quality control and equipment maintenance, purchased with Coating thickness Gauge.

$ 154.00

Measurement principle using ultrasonic, Measurement range 50~ 3800μm, accuracy +/- (2μm + 3%), suitable for concrete and fiberglass substrate Coating thickness detection.

$ 2939.00

Measurement thickness up to 25mm with an error of only +/- 3% with removable FJS Probe for thick protective coating substrates, statistical capabilities and 250,000 Data storage capabilities.

$ 2115.00

Measurement principle using ultrasonic, Measurement range 13~ 1000μm, accuracy +/- (2μm + 3%), suitable for wood, plastic and other substrates polymer Coating thickness detection.

$ 2652.00

Using magnetic Induction and eddy Current principle simultaneous measurement composite coatings, Measurement range 0~ 1500μm, error +/- 1%, can display a single coating and zinc layer thickness, suitable for the accurate detection of ferrous and non-ferrous substrates.

$ 1622.00

Using magnetic Induction and eddy Current dual principle, it can simultaneously measure paints and zinc layer thickness. Measurement range is 0-1500 μm, accuracy is +/- 1%, suitable for composite coating system inspection.

$ 1387.00

Measurement range of 5-500μm with a three-blade design, LED Illumination Microscope and swirl/spin system for accurate assessment of Coating thickness and substrate defects.

$ 296.00

Measurement range 0-3000μm, error +/- 3%, easy to carry and high Stability, suitable for a variety of Coating thickness detection.

$ 461.00

Adopt magnetic Induction principle measurement Coating thickness, Measurement range 0-1250μm, resolution up to 0.1μm, with automatic identification Probe, Data storage and upper and lower limit alarm function, aluminum shell is sturdy and durable.

$ 296.00

Measurement range 2.50-125 mm, accuracy +/- 0.03mm, transparent coating measurement capability, built-in temperature compensation and high-speed scanning function.

$ 2220.00

Support multi-coating system measurement, can measure up to 3 Coating thickness, Measurement range 13~ 1000μm, error +/- (3% H + 2) μm, with 100000 data storage capacity and a variety of Data output methods.

$ 3462.00

Using eddy Current thickness measurement principle, equipped with ultra-thick coating special Probe, Measurement range 0~ 13000 μm, error +/- 3%, can read more than 180 data per minute, support 250,000 Measured value storage.

$ 1760.00

Articles

Taber Abrasion Test Method for Wear Resistance of Coating Films
This article introduces the Taber abrasion test method, which is used to evaluate the ability of coatings, such as those on floors, furniture, or car interiors, to resist mechanical wear.
Standard Test Method for Measuring Optical Haze of Transparent Coated Films Using a Haze Meter
This article introduces the standard method for measuring the optical haze of transparent coated films using a haze meter. First, the instrument must be calibrated according to the standard, and the sample needs to be conditioned in a constant temperature and humidity environment. The measurement involves four steps, including air zeroing, measuring total transmission and scattered light flux, and finally calculating the haze value.
The effect of the substrate fixing method on coating uniformity in a vacuum adsorption blade coating tester.
This article discusses the impact of different substrate fixing methods on coating uniformity in a vacuum-assisted knife-over-roll coating tester. It compares four methods—vacuum adsorption, electrostatic adsorption, mechanical clamping, and adhesive fixing—focusing on their mechanical principles and limitations.
Comparison of Coating Accuracy between Laboratory Blade Coater and Slot Die Coater
This article compares the coating precision of blade coaters and slot-die coaters in the laboratory. Blade coaters are suitable for thick coatings, with simple operation but relatively large uniformity errors; slot-die coaters offer higher precision and better uniformity for thin coatings. The choice of equipment depends on coating thickness and precision requirements.
Flexibility of Elastic Coatings Tested by Cylindrical Mandrel Bend Tester
This article introduces a method for testing the flexibility of elastic coatings using a cylindrical mandrel bending tester. During the test, the coated test panel is bent around cylindrical mandrels of varying diameters to 180 degrees to observe whether the coating cracks or peels off.
Pencil hardness tester rapidly evaluates scratch resistance of paint film.
This article introduces how to quickly assess the scratch resistance of paint films using a pencil hardness tester. During the test, standard pencils (ranging from 6B to 9H) are used to scratch the coating at a fixed angle and pressure to observe whether scratches occur.
Application of Linear Abrasion Tester in Testing Scratch Resistance of Printing Ink Coatings on Packaging
This article introduces the principle, method, and application of the linear abrasion tester in testing the scratch resistance of packaging printing ink coatings.
How to choose a turbidimeter - starting with the measurement principle.
This article introduces how to select a turbidimeter, starting from the measurement principles. The main principles include the scattered light method, transmitted light method, and scattering-transmission ratio method, each suitable for samples with different concentrations.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
Key Operational Points of Solvent Resistance Tester in Evaluating Coating Chemical Resistance
This article introduces the key operational points of the solvent rub resistance tester in evaluating the chemical resistance of coatings. The instrument simulates friction and chemical contact, recording the number of rubs before coating failure to assess performance.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium-Ion Battery Separators
This article discusses the application of automatic film coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional manual coating methods often result in uneven coatings, which can adversely affect battery performance.