Nitrogen-blowing Digester

The nitrogen blowing digestion device heats samples and introduces nitrogen gas to carry away volatile substances, accelerating sample decomposition. It is used in laboratories to process samples such as paints and plastics, removing organic components to facilitate subsequent elemental analysis.
Selection
When selecting a nitrogen-blowing digestion apparatus, consider the sample type and capacity, match the heating temperature range, check the precision of nitrogen flow control, evaluate the corrosion resistance of the materials, and ensure ease of operation and maintenance requirements.

Terms

Instruments

Double needle automatic switching angle to improve condensing efficiency, support 1-8 bit Sample Handling, temperature control accuracy of +/- 0.5 ℃, with independent nitrogen channel and overheating protection to ensure safe and stable operation.

$ 7496.00

Using purge and trap technology, the temperature control accuracy can reach +/- 0.5 ℃, 12 samples can be processed simultaneously, and the nitrogen consumption can be adjusted at 330ml/min/sample to achieve rapid anaerobic condensation.

$ 430.00

Purge and trap technology implementation of rapid oxygen-free condensing, temperature control accuracy of +/- 0.5 ℃, support 36 samples at the same time, nitrogen consumption can be adjusted to 330ml/min/sample, digital temperature control to ensure accurate and reliable operation.

$ 719.00

Purge and trap technology implementation of rapid oxygen-free condensing, temperature control accuracy of +/- 0.5 ℃, nitrogen consumption of 330ml/min/sample can be adjusted, support room temperature to 100 ℃ accurate temperature control.

$ 622.00

Aluminum block Bathroom heat transfer uniform heating, temperature control accuracy +/- 0.5 ℃, gas flow rate 0-15L/min adjustable, blow pipe independent to avoid cross-contamination, to achieve rapid oxygen-free condensing.

$ 498.00

Can process 24 samples at the same time, temperature control accuracy +/- 1 ℃, Gas flow rate of each channel is adjusted separately, self-equilibrating suspension lifting system, 316 stainless steel material corrosion resistance.

$ 535.00

12 samples are processed simultaneously, temperature control accuracy +/- 1 ℃, Gas flow rate can be adjusted separately, self-equilibrating suspension lifting system, 316 stainless steel may be used for solvent contact parts.

$ 472.00

48 samples are processed at the same time, temperature control accuracy +/- 1 ℃, Gas flow rate can be adjusted separately, self-equilibrating suspension lifting system flexibly adjusts the height, 316 stainless steel material is resistant to corrosion and easy to clean.

$ 682.00

With 12 independent control gas paths, each purge needle can be switched on and off separately, temperature control accuracy up to +/- 0.3 ° C, adjustable air cavity height, support for different testtube specifications, built-in over-temperature protection and fault alarm functions.

$ 808.00

36 samples are processed simultaneously, temperature control accuracy +/- 1 ℃, Gas flow rate can be adjusted separately, 316 stainless steel material is used to meet the condensing needs of different samples.

$ 619.00

Each purge needle can independently control and adjust the Flow rate, the temperature control accuracy is +/- 0.5 ℃ @40~ 100 ℃, the position of the air needle is flexible and adjustable, and supports efficient Sampling Handling.

$ 859.00

Flow rate can be controlled independently for each purge needle, and the position of the air needle can be adjusted flexibly. Temperature control accuracy of +/- 0.5 ℃ (40-100 ℃), Heating time does not exceed 30 minutes, support 0-15L/min Gas flow rate adjustment.

$ 1164.00

Aluminum block Bathroom heat transfer uniformity, temperature control accuracy of +/- 0.5 ℃, 36 holes independent air needle channel can avoid cross-contamination, lifting stroke 200mm easy to operate, gas flow 0-15L/min adjustable.

$ 1035.00

The aluminum block Bathroom is used for uniform heat transfer, rapid and accurate temperature control, temperature control accuracy of +/- 0.5 ° C, display accuracy of +/- 0.1 ° C, gas flow rate of 0~ 15L/min, blow pipe to avoid cross-contamination independently, lifting stroke of 200mm.

$ 699.00

Can process 24 samples at the same time, temperature control accuracy of +/- 1 ℃, Gas flow rate of each channel is adjusted separately, using 316 stainless steel material, suitable for 10-29mm testtube, to meet different condensing needs.

$ 1038.00

Articles