Platinum Sensor provides linearly stable measurement results, Conductivity Detector cell constant K = 10, Measurement range 0 to 200mS/cm, suitable for high Conductivity Detector liquid detection.
Conductivity Detector cell constant K = 0.1, built-in temperature sensor real-time sensing sample temperature, suitable for low Conductivity Detector liquid measurement.
Adopting high voltage detection technology, it can sensitively find defects such as coating pinholing and bubbles, equipped with sound and light alarm system, and powered by nickel battery, which is convenient for field operation.
Using platinum sheet material, Conductivity Detector cell constant is 10, suitable for high conductivity environment water measurement, equipped with three core socket interface, no temperature compensation design.
0.6KV~ 31.5KV full scale high voltage output, voltage Accuracy +/- (0.1KV + 3% reading), intelligent control automatically match Coating thickness, pulse discharge to reduce secondary damage, prolong battery life.
Using platinum sheet material, Conductivity Detector cell constant 0.1, no temperature compensation function, suitable for pure water and ultra-pure water and other water quality measurement, optional Glass flow Tank.
Using platinum sheet material, Conductivity Detector cell constant is 1, Measurement range covers 2.0~ 200 µS/cm, suitable for conventional water detection, interface is three-core socket, no temperature compensation function.
Conductivity Detector 1 with platinum sheet material. Measurement range from 200 µS/cm to 200 mS/cm. Suitable for environmental and conventional water detection without temperature compensation.
Platinum Sensor ensures linear and stable measurement, built-in temperature sensor real-time compensation, Measurement range of 0-200mS/cm, suitable for high Conductivity Detector liquids, equipped with 5 Meters low noise Shielding cable.
Using Platinum Sensor to ensure linear and stable measurement, Conductivity Detector cell constant K = 1, Measurement range 0~ 20mS/cm, suitable for conventional liquid detection, Operating temperature 0~ 80 ℃.
Platinum Sensor ensures fast and stable measurement, Conductivity Detector cell constant K = 1, Measurement range 0~ 35mS/cm, Glass shell is durable, suitable for conventional liquid detection.
Glass-lined, FRP, epoxy coal asphalt coatings of different thicknesses can be mass tested by high voltage detection technology. When the coatings have defects such as pinholing and bubbles, the instrument will emit bright sparks and sound and light alarms.
Film thickness 0.1-15 mm, output high voltage 0.8-30 KV stepless adjustable, using integrated high voltage generator to overcome static electricity, sound and light alarm function is suitable for different coating mass detection.
Employing an extrusion production process, the coating thickness is 105 microns, the coating width reaches 300 mm, and the coating accuracy can achieve 0.5 microns, ensuring coating uniformity and high-precision control.
The device adopts destructive measurement, resolution +/- 0.001mm, can carry out V-shaped incision, grid cutting and Cedar test, directly observe Coating thickness and Cedar length, support multi-layer film analysis.