The chemical fiber gloss meter evaluates the gloss characteristics by measuring the intensity of reflected light from the sample surface, utilizing a standard light source and a photodetector to quantify specular reflectance. It is used for quality control of surface gloss in chemical fiber fabrics and plastic products, verifying appearance consistency in textile testing and material acceptance.
Selection
When selecting, ensure the measurement angle matches the gloss range of the sample: use a 20° angle for high gloss, 60° for standard gloss, and 85° for low gloss. Verify that the instrument complies with industry standards such as ASTM D2457, and ensure the calibration plates are intact. Choose the appropriate measurement aperture based on the flatness of the sample, considering the need for portability or a fixed configuration.

Terms

Standards

Instruments

Adopt 60 ° Measurement Angles, Measurement range 0~ 199.5GU, Indication Error +/- 2GU, built-in rechargeable battery can last for more than 24 hours to meet the needs of surface Gloss measurement of various materials.

$ 283.00

The 45 ° ring illumination structure is used to eliminate the direction dependence, the Inter-instrument Agreement Delta E * ab Technologies 0.2, the chromatic value Repeatability Delta E * ab 0.03, the built-in Gloss Sensor realizes the simultaneous measurement of Color Gloss, and the test port is designed to support a variety of morphological samples.

$ 9078.00

Using 20 degree Measurement Angles, Measurement range 0~ 300GU, Indication Error +/- 1.2GU, equipped with elliptical measurement port and Ni-MH rechargeable battery, suitable for high Gloss object surface detection.

$ 448.00

Ceramic fiber Furnace to achieve multi-faceted heating, Temperature uniformity less than +/- 5 ℃, heating rate ≥ 10 ℃/min, with nitrogen filling device to slow down oxidation and flue discharge of harmful gases.

$ 1937.00

Adopt 45 ° circular lighting structure, reduce texture effect, compatible with 60 ° Gloss measurement, Repeatability Delta E * ab 0.03, built-in high Sensitivity Sensor, suitable for matte and textured material surfaces.

$ 6334.00

The three-angle measurement design covers 20 °/60 °/85 °, the measurement range is 0.1~ 200GU, the repeability is +/- 0.5GU, and 254 sets of data storage and Bluetooth output are supported to meet the needs of surface Gloss detection of various materials.

$ 336.00

Adopt 60 ° Measurement Angles, Measurement range 0~ 1000GU, Repeatability 0.2GU, support USB and Bluetooth interface, can store 10000 sample data, suitable for surface Gloss measurement of various materials.

$ 332.00

Adopting frequency conversion stirring technology, the impeller Rotation speed can be adjusted from 1000-3600rpm, and supports two test modes of counting and not counting to ensure that the fiber retains its original structural properties during the wet dissociation process.

$ 2073.00

Pottery and porcelain fiber Furnace and multi-faceted heating technology, Temperature Fluctuation +/- 2 ℃, energy saving rate of 40%, with 30 program settings and over-temperature protection function.

$ 2744.00

Using electronic technology and LCD screen, impeller rotation frequency 49 +/- 1.5S-1, motor power 370W, wet dissociation pulp to maintain the original fiber structure, easy to operate.

$ 1542.00

45 ° ring illumination and 0 ° viewing angle structure are used to effectively eliminate mirror light interference on textured surfaces. Built-in Gloss Sensor realizes simultaneous measurement, and the spectral reflectance Repeatability Standard Deviation is within 0.08%, suitable for matte and textured materials.

$ 3753.00

The samples were treated by acid-base cooking method, and 6 samples could be measured each time. The repeatability error of the absolute value of crude fiber content below 10% did not exceed 0.4%, and the determination time was about 100 minutes.

$ 912.00

Ceramic fiber material, Temperature range, Temperature Fluctuation +/- 0.5 ℃, support multi-stage programmable control, independent temperature limit alarm system to ensure safe operation.

$ 2466.00

Pottery and porcelain fiber Furnace to achieve multi-faceted heating, temperature uniformity +/- 2 ℃, heating rate 1-30 ℃/min adjustable, with 30 programming and double over-temperature protection function.

$ 1661.00

Pottery and porcelain fiber Furnace and multi-faceted heating technology, temperature uniformity +/- 2 ℃, heating rate 1-30 ℃/min adjustable, with 30 programming and over-temperature protection function, energy saving rate of 40%.

$ 4737.00

Articles

Gloss meter measures the surface brightness of packaging film.
This article introduces the principle and method of using a gloss meter to measure the surface glossiness of packaging films. The gloss meter quantifies the specular reflection capability of a surface in gloss units by measuring the ratio of reflected light from the sample to that from a standard plate.
Gloss meter measures the gloss consistency of resin coating film surfaces.
This article introduces how to use a gloss meter to measure the gloss consistency of resin coating film surfaces.
Application of Gloss Meter in Gloss Measurement of Varnish Coatings
A gloss meter is used to measure the gloss of varnish coatings by detecting surface-reflected light to quantitatively assess the appearance of the coating. The measurement is based on the principle of specular reflection of light, commonly employing angles such as 20°, 60°, and 85° to correspond to different gloss ranges, and follows standard formulas for calculation.
Glossmeter 75-degree angle measurement for paper gloss
This article introduces the principle and method of measuring paper gloss using a 75-degree specular gloss meter. Gloss is defined as the ratio of the light reflected from the paper surface to that reflected from a standard reference plate, with the 75-degree angle commonly used for measuring medium to high gloss papers.
Three-angle gloss meter for evaluating coatings with different gloss levels
Glossiness is a key indicator for evaluating the optical properties of a surface, defined as the ratio of the reflected luminous flux to the incident luminous flux, typically expressed as a percentage or in gloss units.
Method for measuring the gloss of ink surfaces using a gloss meter
This article introduces the method of measuring the surface gloss of ink using a gloss meter. Gloss is a key indicator of the visual quality of ink, and the instrument quantifies gloss by measuring reflected light at specific angles.
The use of a gloss meter in evaluating the surface gloss of printing paper and art paper.
Gloss meters quantify paper gloss by measuring surface reflected light, with 20°, 60°, and 85° angles commonly used for high, medium, and low gloss surfaces, respectively. The gloss characteristics of printing paper and art paper differ, so the appropriate measurement angle should be selected based on the estimated gloss level.
Determination of specular gloss: Selection criteria for instruments at different angles (20°/60°/85°)
Specular gloss is a measure of a material's ability to reflect light, calculated by comparing the reflected luminous flux of a sample with that of a standard plate. Three angles—20°, 60°, and 85°—are commonly used for measurement, corresponding to high-gloss, medium-gloss, and low-gloss surfaces, respectively.