Metal Damp Heat Alternating Test Chamber

The metal damp heat alternating test chamber simulates alternating environments of high temperature and humidity with low temperature through a temperature and humidity controller, causing condensation to form on the surface of metal samples. It is used to test coating adhesion and the corrosion resistance of metal substrates, and is applied in the testing of protective layers for automotive components and electronic components.
Selection
When selecting, confirm that the temperature and humidity range covers the testing standards, the inner chamber material is corrosion-resistant, and the sensor accuracy meets data requirements. Evaluate the heating and cooling rates as well as uniformity, and ensure the program editing function is suitable for cyclic testing. Choose the equipment size based on sample specifications, and consider the convenience of after-sales maintenance.

Terms

Standards

Instruments

Using Japan's Panasonic Compressor and the United States DuPont environmental protection refrigerant, temperature control accuracy of +/- 0.5 ℃, Temperature resolution 0.01 ℃, with program control and Data storage functions, support high temperature, low temperature and heat and humidity alternating test.

$ 5479.00

Infrared heat source for fast drying, Power 550W, metal material to ensure durability, built-in heating element to pRoduce uniform heat cycle, effective evaporation of water, suitable for drying various materials.

$ 159.00

Using stainless steel mirror liner and French Taikang Compressor, temperature range -60~ 150 ℃, Fluctuation ≤ +/- 0.5 ℃, equipped with large screen Touchscreen and multiple safety protection system, high test accuracy and stable and reliable.

$ 7222.00

Adopt stainless steel mirror liner and A3 steel plate spray shell, equipped with 7 inch Touchscreen control instrument, Temperature Fluctuation ≤ +/- 0.5 ℃, uniformity ≤ +/- 2 ℃, support -20~ 150 ℃ wide temperature range test, with PID automatic calculation function.

$ 9481.00

Adopt equilibrating Conditioning Control system, Temperature range -20~ 150 ℃, humidity control 20~ 98% RH, equipped with imported Compressor and multi-stage PID calculation, ensure uniform and stable heat preservation Humidity, energy saving and high efficiency.

$ 2457.00

The rectangular vacuum Chamber improves space utilization, Vacuum Level up to 133Pa, is equipped with double-decked tempered Glass doors for easy observation, supports program control of heating and vacuum holding time, and improves processing conformity.

$ 2939.00

The rectangular vacuum Chamber improves space utilization, the stainless steel studio is durable and easy to clean, the Vacuum Level is 133Pa, the double-decked tempered Glass door is easy to observe, and the optional program control ensures the stoving conformity.

$ 3294.00

Using Nidec compressor and DuPont environmental protection refrigerant, Humidity control accuracy of 0.1 ℃, equipped with double-decked vacuum heating defrosting observation window and stainless steel sample holder, support multi-stage programming and Data storage.

$ 3301.00

Using stainless steel mirror liner and French Taikang Compressor refrigeration, Temperature Fluctuation ≤ +/- 0.5 ℃, equipped with 7-inch Touchscreen control, support multi-wing air supply circulation to ensure uniform temperature.

$ 9078.00

The heat sealing paraMeters were determined by hot-pressing sealing method, the temperature control accuracy was +/- 1 ℃, the heat sealing time was adjustable 0.1-999 s, the upper and lower heat heads were independently controlled, and the double-decked heat insulation design ensured the safety of use.

$ 1200.00

The heat sealing performance was determined by hot pressing sealing method, the temperature control accuracy was +/- 0.2 ℃, the heat sealing time was 0.1~ 999.9s, the upper and lower heat heads were independently controlled, and the double-decked heat insulation design ensured safety.

$ 1603.00

Temperature range RT +~ 300 ℃, temperature control accuracy +/- 0.2 ℃, heat sealing time 0.1~ 999.9s adjustable, heat head with brass material to ensure uniform heat conduction, double-decked thermal insulation protection to ensure safe operation.

$ 3015.00

The rectangular vacuum Chamber improves space utilization, the stainless steel studio is durable and easy to clean, the Vacuum Level 133Pa ensures efficient handling, double-decked tempered Glass doors are easy to observe, and over-temperature protection enhances safety.

$ 4222.00

Adopt stainless steel mirror liner and A3 steel plate spray shell, equipped with 7 inch Touchscreen control, Temperature Fluctuation ≤ +/- 0.5 ℃, uniformity ≤ +/- 2 ℃, support rapid temperature rise and drop, in line with GB2423 and other standards.

$ 6819.00

Using stainless steel mirror liner and French Taikang Compressor refrigeration, Temperature Uniformity ≤ +/- 2 ℃, equipped with 7-inch Touchscreen and PID automatic calculation function, can achieve rapid temperature rise and fall test.

$ 11611.00

Articles

Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Cup Test Instrument for Coating Tests the Impact and Deformation Resistance of Coatings on Metal Substrates.
This article introduces how the coating cupping tester measures the resistance to stamping deformation of coatings on metal substrates.
T-bend tester for coatings is used to determine the T-bend grade of metal sheet coatings.
This article introduces how the T-bend tester for paint films is used to evaluate the flexibility and adhesion of coatings on metal sheet surfaces.
Brinell hardness tester is used for hardness testing of plastics and soft metal coatings.
This article introduces how a Brinell hardness tester is used to measure the hardness of plastics and soft metal coatings.
Atomic Absorption Spectrometer for Measuring Heavy Metal Content in Rubber
This article introduces a method for determining the heavy metal content in rubber using atomic absorption spectrometry. It first explains that rubber may contain harmful elements such as lead and cadmium, which require accurate measurement.
Controllable Coating of Composite Separator Coatings for Lithium Metal Batteries
This article primarily explores the controllable coating technology for composite separator coatings in lithium metal batteries.
Preparation of metal thin films by the coating method for mechanical property studies.
This paper discusses the key process parameters in the preparation of metal thin films using a film coater and their effects on mechanical properties. The film coater forms metal thin films on a substrate through solution deposition, with its uniformity and repeatability directly influencing film quality.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Use of Muffle Furnace for Ash Determination in Pulp Inorganic Matter Testing
This article introduces the application of the ash determination muffle furnace in the detection of inorganic substances in pulp. The muffle furnace removes organic matter in the sample through high-temperature combustion, and the remaining inorganic residue, known as ash, is used to analyze the content of fillers and metal ions in the pulp.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
Atomic Absorption Spectrometer for Determining Heavy Metal Content in Coatings
This article introduces a method for determining the content of heavy metals such as lead, cadmium, chromium, and mercury in coatings using atomic absorption spectroscopy. The method is based on the absorption of characteristic wavelength light by atoms for quantification. It requires acid digestion pretreatment of coating samples and optimization of instrument conditions to improve accuracy.
Applicable Scenarios for Neutral Salt Spray and Copper-Accelerated Acetic Acid Salt Spray Tests
Neutral salt spray testing and copper-accelerated acetic acid salt spray testing are both accelerated methods used to evaluate the corrosion resistance of materials, simulating saline environments to predict long-term performance. The neutral salt spray test uses a neutral sodium chloride solution, which causes relatively mild corrosion and is suitable for general metals and coatings, such as automotive parts.