High Accuracy temperature control technology, Temperature range RT +~ 400 ℃, resolution 0.1 ℃, support 0.1~ 20 ℃ stepless heating, high-resolution video observation melting process, no map but can store 400 data.
Using high-resolution video technology instead of traditional Microscope, it can process 4 samples at a time, Temperature range RT +~ 350 ℃, accuracy +/- 0.1 ℃, support powder and bulk sample measurement, automatic recording of melting range data.
Using 30fps high-resolution video and 720P camera to observe the sample melting process in real time, support 0.1-20 ℃/min heating rate adjustable and four capillary tubing simultaneous processing, in line with pharmacopoeia specifications.
Using high-resolution video camera technology instead of traditional Microscope, it can process 4 samples at a time, automatically record the melting range, Temperature range RT +~ 420 ℃, heating rate 0.1~ 20 ℃ stepless adjustable.
Using 30fps high frame rate video monitoring and 720P high definition camera, support 0.1 ℃/min-20 ℃/min heating rate adjustment, integrated heating Furnace design to ensure temperature control accuracy, can store 40,000 sets of spectrum data.
Equipped with a high definition camera module can clearly observe the sample melting process, process 4 samples at a time, Temperature range RT +~ 420 ℃, heating rate 0.1~ 20 ℃ infinitely adjustable, automatic recording of melting distance and initial melting and final melting.
Using platinum temperature sensor and digital Optical inspection technology, temperature control accuracy 0.1 ℃, can process 2 samples at the same time, with video recording playback function, support 0.1-10 ℃/min heating rate.
Using photoelectric automatic detection and PID adjustment technology, temperature range RT +~ 300 ℃, resolution 0.1 ℃, can automatically calculate the average melting point and record the melting Linear dispersion, support three capillary tubing simultaneous measurement.
Using PID system control and High Accuracy temperature sensor, Temperature range RT +~ 350 ℃, melting point Test accuracy is the highest +/- 0.5 ℃, heating rate 3.0 ℃ -5 ℃/min, to ensure stable and efficient testing.
It can process 4 samples at a time, realize one-button measurement function, Temperature range RT +~ 400 ℃, heating rate 0.1~ 20 ℃ stepless adjustable, automatic recording of melting distance, initial melting and final melting, with 10 sets of spectrum storage and 400 Data storage capacity.
With five linear heating rate setting, Temperature range RT + to 400 ℃, resolution 0.1 ℃, support capillary method and coverslip method measurement, high magnification microscopic observation of melting details, suitable for a variety of Sample types.
Support capillary tubing and hot stage two measurement methods, temperature range RT +~ 320 ℃, Microscope 40 times magnification observation, sexual repeability +/- 1 ℃ (≤ 200 ℃), to meet the melting point of crystalline organic compounds determination needs.
Using photoelectric automatic detection and PID adjustment technology, temperature range RT +~ 320 ℃, resolution 0.1 ℃, automatically display the initial and final melting and record the melting Linear dispersion, improve measurement accuracy and reliability.
Adopt high definition camera to observe the measurement process in real time, dual-channel simultaneous detection, adjustable heating rate 0.1-20 ℃/min, support video playback and automatic interpretation of deformation characteristics.
Using PID temperature control technology to ensure accurate and stable temperature, temperature resolution of 0.1 ℃, support capillary method and hot table method two measurement methods, microscopic camera real-time display of melting process, data can be stored and transmitted.