Infrared Contactless ThermoMeter

The infrared non-contact thermometer converts the infrared radiation energy emitted from the surface of an object into a temperature reading. It is used for quickly measuring the surface temperature of objects, making it suitable for detecting high-temperature, moving, or hard-to-reach objects.
Selection
When selecting, consider whether the temperature measurement range covers the requirements, whether the measurement accuracy meets the application, whether the response speed suits the scenario, whether the emissivity is adjustable to match material characteristics, and evaluate the impact of environmental factors such as dust or steam.
type
How it works
upper limit of temperature measurement
lower limit of temperature measurement
DS object distance ratio
precision

Terms

Standards

Instruments

Using infrared Light spectrum measurement technology, the temperature measurement range covers -18 to 1150 ° C, the accuracy is +/- 2%, with 20:1 object distance ratio and 500ms fast Response, support Data storage and USB connection function.

$ 153.00

Far infrared radiation heating technology, equipped with thermistor control thermoMeter, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, with fast drying and low energy consumption characteristics, suitable for a variety of Sample Handling.

$ 586.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, automatic thermostatic control, fast drying and low energy consumption.

$ 883.00

Equipped with Infrared Sensor and Thermal Probe Dual Measurement mode, Response Time is only 1 second, Optical inspection coefficient is 3:1, support -40~ 150 ℃ wide range temperature measurement, to meet the needs of accurate temperature detection in different scenarios.

$ 654.00

Using shortwave infrared technology, temperature range 200~ 2200 ℃, accuracy +/- 2%, with laser positioning, data retention and emissivity adjustable functions, Response Time 500ms, object distance ratio 80:1.

$ 307.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, fast low consumption adjustment is convenient.

$ 507.00

With -50~ 900 ℃ wide range and +/- 2% accuracy, 12:1 object distance ratio for non-contact measurement, Response Time 500ms, compact and lightweight only 170g, suitable for high temperature or hazardous environment.

$ 114.00

Far infrared radiation heating technology, temperature control accuracy +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, Inner Chamber dimensions 320 * 380 * 320mm.

$ 391.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, suitable for a variety of Sample Handling.

$ 1009.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, temperature fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, with fast, low consumption, easy adjustment and other advantages, suitable for drying a variety of samples.

$ 465.00

Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, with fast drying, low energy consumption and easy adjustment, suitable for a variety of Sample Handling.

$ 581.00

Non-contact measurement avoids contact with dangerous objects, Response Time 500ms Fast reading temperature, temperature range -32~ 550 ℃ covers a wide range of scenarios, compact structure and easy to operate.

$ 85.00

Temperature measurement range 200~ 1850 ℃, object distance ratio 80:1, Response wavelength 900~ 1700nm, support Data storage and USB connection, suitable for long-distance accurate measurement.

$ 263.00

With a wide temperature measurement range of -50~ 480 ℃, the accuracy is +/- 1.5%, the Response Time is only 500ms, the object distance ratio is 12:1, suitable for fast non-contact measurement, lightweight and portable.

$ 103.00

The equipment temperature range -32~ 400 ℃, accuracy +/- 2%, object distance ratio 12:1, support laser positioning and backlight display, Response Time 500ms, easy to fast non-contact operation.

$ 94.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Roughness Measurement Instrument Selection: Contact vs. Non-Contact
This article introduces the differences between contact and non-contact methods when selecting a roughness measuring instrument.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Comparison of Selection Parameters for Stylus and Laser Roughness Measuring Instruments
Stylus-type roughness measuring instruments perform contact scanning to measure two-dimensional profile parameters in accordance with standards such as ISO 4287, while laser-based instruments utilize non-contact optical principles and refer to ISO 25178.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Principles and Selection of Film Thickness Measurement Instruments
This article introduces the principles and selection methods of thin film thickness measurement instruments. The measurement principles are mainly divided into contact and non-contact methods, which calculate thickness by detecting the differences in the thin film's response to physical signals.
Xenon lamp aging test chamber for testing coating weatherability.
Xenon lamp aging test chambers accelerate the testing of weather resistance for materials such as coatings in the laboratory by simulating the ultraviolet, visible, and infrared portions of sunlight, while controlling conditions like temperature, humidity, and water spray.
How to Choose the Right Spectrophotometer
When selecting a spectrophotometer, it is essential to start from the actual analytical needs, clearly defining the required wavelength range (ultraviolet, visible, or infrared) and the type of detection. Key evaluations should focus on core specifications of the optical system, such as wavelength accuracy, beam type, and stray light levels.