Copper Strip Corrosion Tester

The copper strip corrosion tester simulates atmospheric conditions to bring copper strips into contact with corrosive media, inducing chemical reactions and allowing observation of surface discoloration or corrosion levels. It is used to evaluate the corrosion resistance of materials and is commonly applied in quality control for petroleum products, coatings, and chemical products.
Selection
When selecting, ensure the testing standards comply with industry norms, and verify the precision of temperature and humidity control as well as the stability of gas flow. Consider the compatibility with sample sizes and the convenience of the operation interface, and choose between manual or automatic models based on daily testing volume.

Terms

Standards

Instruments

The minimum measurable inner diaMeter is 10mm, the maximum sample thickness is 6mm, and the imported special steel crimp and high-strength pointer components are used. It has good Stability and portability and supports Hardness value conversion.

$ 1017.00

Providing stable copper Ion concentration standards to ensure ElectRode Measurement accuracy, 250ml Encasement meets the daily calibrating needs of the laboratory and is suitable for a variety of copper ion detection scenarios.

$ 110.00

The ElectRode is a composite design with a 60mL reference filler and calibrating solution combined with an ionic strength modifier for accurate measurement of Cu Ion concentration and comes with a polishing strip for easy maintenance.

$ 309.00

The device can precisely control the film thickness of the ink layer of the color strip, and the ink injection amount is 0.0012g, which is used for ink contrast and color concentration detection.

$ 173.00

Measurement range 0.00~ 5.00 ppm, accuracy +/- 0.05 ppm, using LED@575nm Illuminant, chemical reaction based rapid detection of copper Ion concentration, suitable for field and laboratory applications.

$ 215.00

The copper Cup ensures durability, the diaMeter of the flow hole is 4mm with the capacity of 100ml, and the measurement time range is 0~ 150s, which is suitable for conditional viscosity determination.

$ 141.00

Measurement range 0-150 seconds, copper material is durable and in line with national standards, portable design is convenient for on-site rapid detection of Coating viscosity.

$ 123.00

Concentration 1000ppm of copper ion standard solution, PTFE bottle Encasement, capacity 480mL, suitable for daily ion calibrating applications.

$ 135.00

Colorimetric measurement is achieved using the bischell method. Measurement range 0.00-5 mg/L, 100 tests are provided, and copper concentration is accurately determined by Color change.

$ 186.00

Designed for Bromo Iodine Copper Ion Composite ElectRode, it provides a stable reference potential to ensure measurement accuracy, and 250ml Encasement meets the needs of routine laboratory use.

$ 99.00

Using copper nickel plating material, volume 37ml, in line with GB/T6750 standard, equilibrium hammer is hollow structure and filled with lead particles to adjust the weight, suitable for Coating and auxiliary materials, oil and other liquids specific gravity determination.

$ 106.00

Using copper plate platform and long-life heating tube, PID intelligent temperature control accuracy +/- 1 ℃, rapid heating to 200 ℃ only 10 minutes, suitable for a variety of Resin materials gel time determination.

$ 509.00

The mechanical compression spring device is not easy to damage, the accuracy is up to 0.5HW, the film thickness 0.4-6 mm workpiece can be detected, and various Hardness values such as Brinell Rockwell can be obtained through the conversion table.

$ 477.00

Can detect the minimum 6mm inner diaMeter brass thin tube, range 0-20HW, Indication Error 0.5HW, using high strength pointer and special steel pressure needle, Stability is good and support multiple Hardness value conversion.

$ 1219.00

Measurement range 6.35μg/L to 63.5mg/L, resolution up to 0.01 pCu, support pCu and concentration conversion, easy operation and high Stability.

$ 382.00

Articles

Salt spray aging test chamber for cyclic corrosion evaluation of coating weatherability.
This article introduces the method of using a salt spray aging test chamber to conduct cyclic corrosion tests for evaluating the weather resistance of coatings.
Salt spray test chamber for testing the corrosion resistance of plastic coatings.
The salt spray test chamber accelerates the testing of the corrosion resistance of plastic surface coatings by simulating a salt spray environment containing chloride ions. The test is conducted in accordance with international standards such as ASTM B117 or ISO 9227, and the process includes sample preparation, salt spray exposure, and result evaluation.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Application of Coulometric Moisture Titrator in Moisture Detection of Electronic Components
Coulometric moisture titrators operate based on the principle of electrolysis, directly calculating the moisture content in samples by measuring the electrolytic charge without the need for calibration. In the field of electronic components, moisture can lead to issues such as corrosion and reduced insulation, making its detection critically important.
Automatic Potentiometric Titration for Rapid Detection of Chloride Ion Content in Cement
This article introduces a method for rapidly detecting the chloride ion content in cement using an automatic potentiometric titrator. Excessive chloride ions can corrode steel reinforcement and affect the lifespan of concrete, making accurate detection crucial.
Salt spray test chamber detects the corrosion resistance of coatings.
The salt spray test chamber accelerates the testing of coating corrosion resistance by simulating a salty and humid environment. It uses atomized sodium chloride solution to form salt spray, which settles inside the constant temperature chamber, and conducts tests under neutral or acidic conditions in accordance with standards.
Applicable Scenarios for Neutral Salt Spray and Copper-Accelerated Acetic Acid Salt Spray Tests
Neutral salt spray testing and copper-accelerated acetic acid salt spray testing are both accelerated methods used to evaluate the corrosion resistance of materials, simulating saline environments to predict long-term performance. The neutral salt spray test uses a neutral sodium chloride solution, which causes relatively mild corrosion and is suitable for general metals and coatings, such as automotive parts.
Salt spray test chamber evaluates the protective performance of powder coatings
The salt spray test chamber accelerates the evaluation of the corrosion resistance of powder coatings by simulating a salty and humid environment. The test is based on electrochemical principles, where salt spray penetrates coating defects and initiates corrosion of the metal substrate. During operation, parameters such as temperature and sedimentation rate must be strictly controlled, and standards such as ISO and ASTM must be followed.
Application of Salt Spray Test Chambers in Corrosion Resistance Testing of Automotive Components
The salt spray test chamber simulates a salty and humid environment to accelerate the testing of the corrosion resistance of automotive components. Its principle is based on electrochemical corrosion, allowing for the control of key parameters such as salt concentration and temperature.
Selection of Ceramic vs. Cast Aluminum Heating Surfaces for Laboratory Hot Plates
When selecting a laboratory heating plate, ceramic and cast aluminum are two common materials. Ceramic offers high-temperature resistance, corrosion resistance, and uniform heating, but it heats up slowly and is relatively brittle. Cast aluminum heats up quickly and is sturdy and durable, but it has weaker corrosion resistance and a lower maximum temperature.
Application of Damp Heat Testing in the Environmental Adaptability Verification of Automotive Components
Humidity and heat testing is an accelerated test method that simulates high-temperature and high-humidity environments, used to evaluate the performance changes of automotive components under humid conditions. It primarily examines the insulation and corrosion resistance capabilities of electrical and electronic components, the aging resistance of interior materials, and the corrosion prevention effectiveness of exterior structural parts.