Cyanide

Cyanide blocks cytochrome oxidase in the cellular respiratory chain, leading to tissue hypoxia. It is used in detection to analyze the content of toxic substances in environmental, food, and industrial samples, ensuring safety standards.
Selection
When selecting a cyanide detection method, consider the sample type, detection limit requirements, and regulatory standards. Choose between spectrophotometry or ion-selective electrode methods based on laboratory conditions and cost factors.

Instruments

Using imported cold light source and narrow-band interference technology, the detection limit is 0.004mg/L, supporting continuous measurement and standard measurement modes, and the built-in large-capacity lithium battery can store 4000 sets of data.

$ 816.00

Using electrochemistry gas Sensor, Response speed, Measurement accuracy. Support 4-20mA, RS485 and other signal output, with overvoltage, lightning protection, short circuit and other multiple circuit protection functions, remote monitoring and data query.

$ 751.00

Modular design, support intelligent Sensor detection technology, with an overall explosion-proof structure, can be directly installed in dangerous areas. Standard configuration point array LCD display, sound and light alarm and a variety of signal output, support multi-gas multi-range detection and remote monitoring.

$ 590.00

Imported high-luminance Illuminant and narrowband filter system, Optical inspection stability ≤ 0.002A/20min, measurement range 0.01~ 0.50mg/L, equipped with large-screen LCD Chinese display, support long-term data storage and user self-calibration.

$ 499.00

Measurement accuracy of 1% and automatic temperature compensation, support 2-5 point calibrating and 500 data storage, provide automatic end point locking and a variety of concentration unit selection.

$ 696.00

Adjustment with 5-point buttons, support automatic temperature compensation to ensure full-scale measurement accuracy, built-in 500 data storage capacity, equipped with large-screen backlit LCD display, Measurement accuracy of 1% F.S.

$ 696.00

Measurement range 10-2-10 -6mol/L, temperature range 5-60 ℃, strong compatibility of BNC interface, high detection sensitivity.

$ 125.00

Electrochemical sensor, resolution up to 0.1ppm, Response Time less than 60 seconds, with sound, light, vibration triple alarm, Protection Rating IP65, adapt to harsh environment.

$ 235.00

Using industrial grade Sensor, Response Time T90 is less than 60 seconds, resolution up to 0.1/0 ppm, with waterproof, dustproof and explosion-proof function, small and durable suitable for industrial field use.

$ 248.00

Adopt MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, support 4-20mA, RS485 and switch output, with explosion-proof structure and remote control operation function, Response Time ≤ 30 seconds.

$ 848.00

Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds, support a variety of signal output and wireless transmission, with explosion-proof structure and remote alarm function.

$ 280.00

Support 5 point calibrating and 8 calibrating liquid selection, provide 5 Ion concentration Measuring methods, equipped with ElectRode management function to store 3 ElectRode slopes, with automatic end point locking and limit alarm function.

$ 733.00