Natural Convection Incubator

Natural convection incubators utilize internal heating elements to cause air to rise when heated and sink when cooled, forming a circulation without the need for fans for forced convection. They maintain a constant internal temperature through a temperature control system and are used for experiments sensitive to airflow disturbances, such as microbial cultivation and seed germination. The incubator body typically features a double-layer structure to minimize heat loss.
Selection
When selecting, ensure the temperature range covers experimental needs, with fluctuations controlled within ±0.5℃. Prioritize stainless steel for the inner chamber, and the observation window should be double-glazed. Determine the capacity based on sample volume, paying attention to the insulation and sealing of the chamber. The temperature control system should be user-friendly and equipped with over-temperature protection. The provided sample racks must meet placement requirements.

Terms

Standards

Instruments

Adopt natural convection cycle to avoid sample volatilization, stainless steel liner is easy to clean, temperature control accuracy of +/- 0.5 ℃, optional multi-stage programming and independent temperature limit alarm system.

$ 419.00

The natural convection cycle design ensures uniform temperature, temperature control accuracy of +/- 0.5 ℃, timing function up to 9999 minutes, suitable for drying, sterilizing and other applications.

$ 1569.00

Using natural convection design to ensure uniform temperature, Temperature range RT + 10~ 400 ℃, Temperature resolution 0.1 ℃, with timing function and multiple alarm system to ensure safe and reliable operation.

$ 598.00

Temperature uniformity with natural convection design, temperature control accuracy of +/- 0.5 ° C, volume of 70L, independent temperature limit alarm system and timing function for 9999 minutes, suitable for a variety of drying sterilizing applications.

$ 761.00

The dust density is measured by natural accumulation method, the diaMeter of the outflow port is 12.7mm, the funnel taper is 60 ° +/- 0.5 °, to ensure the stability of the free fall process, the volume of the measuringflask is 100mL, and the material is durable and easy to clean.

$ 235.00

Using natural convection cycle to avoid sample volatilization, Temperature range 10~ 200 ℃ and Fluctuation +/- 0.5 ℃, equipped with over-temperature protection and programmable function to achieve safe automatic operation.

$ 633.00

140L large capacity studio, Temperature range RT + 10~ 400 ℃, Temperature Fluctuation +/- 0.5 ℃, natural convection design to ensure uniform temperature, timing function up to 9999 minutes, support Sensor fault alarm and over temperature protection.

$ 1174.00

Using 60 ° taper funnel and 100ml standard glassgraduates with scale, the unit volume mass of the dust in the loose state was measured by free fall to ensure the accuracy and reliability of the test results.

$ 378.00

Dual duct forced convection design makes Temperature Uniformity up to +/- 1.0 ℃, Fluctuation +/- 0.5 ℃; Speed control fan supports lightweight Sample Handling, low water level alarm and forced cooling structure to improve safety, support 0~ 9999 minutes timing.

$ 909.00

Temperature range foster RT + 5~ 80 ℃, drying 80~ 220 ℃, using mirror stainless steel liner and forced convection technology to ensure uniform temperature, four corners and a half arc easy to clean, the door opens automatically stop heating.

$ 1125.00

Fuzzy PID controller is used to ensure accurate temperature fluctuation, forced convection duct to raise Temperature uniformity to +/- 1.5 ℃, automatic control of circulating fan speed to avoid sample volatilization, mirror stainless steel liner and electric heating film Heating mode to achieve rapid and uniform heating.

$ 804.00

Using semiconductor Sensor technology, the detection sensitivity can be adjusted to 50PPM methane, Response Time ≤ 1 second, Warm-Up Time is less than 110 seconds, support 9 hours of continuous work, with LED light alarm and low power indication function.

$ 99.00

The mirror stainless steel liner is easy to clean, the natural convection cycle is noise-free to avoid sample volatilization, the temperature control is accurate and the fluctuation is small, Temperature Fluctuation +/- 0.5 ℃, with independent temperature limit alarm and timing function.

$ 678.00

Mirror stainless steel liner is easy to clean, natural convection cycle to avoid sample volatilization, temperature control accuracy 0.1 ℃, programmable multi-stage control, independent temperature limit alarm system to ensure experimental safety.

$ 906.00

Dual duct forced convection design to ensure Temperature Uniformity +/- 1.0 ℃, Fluctuation +/- 0.5 ℃, speed control fan to adapt to lightweight samples, support 0~ 9999 minutes timing operation, with over-rise prevention and low water level alarm and other safety features.

$ 1054.00

Articles

Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
The necessity of a standard light source box in visual color comparison and color difference assessment of coatings.
In the production of coatings, accurate color evaluation is crucial. Visual color comparison is easily affected by light, as natural light is unstable, and different lighting conditions can make colors appear different.
What are the differences between a vacuum oven and a conventional oven?
The main difference between a vacuum oven and a conventional oven lies in their working pressure. Conventional ovens operate at atmospheric pressure, heating through air convection, making them suitable for routine drying tasks. In contrast, vacuum ovens are evacuated to low pressure to reduce air presence, primarily relying on thermal radiation for heat transfer. This makes them ideal for processing heat-sensitive, oxidation-prone materials or those requiring thorough drying.
Natural Convection vs Forced Air Drying: What’s the Difference Between the Two "Schools" of Laboratory Ovens?
This article introduces two drying methods for laboratory ovens: natural convection and forced air drying. What are the differences between them?