Flow rate of scruf liquid can be precisely controlled by using double brush to accelerate the simulated abrasion scraping experiment, and various consumables such as brush, scruf pad and sponge can be compared and tested.
Temperature range -5~ 80 ℃, Humidity deviation +/- 3% RH, mirror stainless steel liner and JAKEL circulating fan to ensure Temperature uniformity, support 99 cycle complex experimental procedures.
Using Japan Panasonic Compressor and binary low temperature circuit system, Temperature range -70 ℃~ + 150 ℃, Temperature Uniformity ≤ 2 ℃, equipped with double-decked vacuum Glass observation window and automatic water replenishment device.
Adopting double-decked Vacuum Reinforced Glass observation window and SUS304 stainless steel inner box, the temperature control accuracy reaches +/- 0.5 ℃, supports program test and Data storage function, and meets the strict environment Reliability verification requirements.
High Accuracy Electromagnetic Force Sensor, repeatability error +/- 2mg, 5-inch color Touchscreen for glove operation, automatic internal calibrating and Sensor transport protection.
With a standard 45 degree tilt angle, the same as the light box base color does not interfere with the viewing effect, Dimension 395 * 350mm, weight 1.2Kg, flexible placement and easy to disassemble and transport.
Using a new generation of electromagnetic force Sensor, weighing accuracy of 1mg, repeatability error +/- 2mg, equipped with a 5-inch color Touchscreen to support glove operation, with automatic internal calibrating and transport protection devices.
Rotation speed of 3000rpm, Processing capacity 20m ³/h, using three groups of stator structure to achieve strong impact and shear, with strong self-priming capacity and low lift transport function, can operate stably for a long time.
Using Japanese Panasonic Compressor and binary cryogenic loop system, temperature control accuracy of +/- 0.5 ℃, equipped with double-decked vacuum Glass observation window and SUS304 stainless steel inner box, support multi-stage programming and USB Data storage, Temperature Uniformity ≤ 2 ℃.
Adopt double-decked Vacuum Glass observation window and SUS304 stainless steel inner box, temperature control accuracy of +/- 0.5 ℃, support program test and data recording function, equipped with multiple Safety protection system to ensure reliable operation.
With six-level adjustable light and 0.1 ℃ Temperature resolution, it can simulate the change of day and night temperature and Humidity, and supports 30 sets of program settings to ensure the safe and stable operation of the experiment.
Adopt cascade refrigeration system to achieve 0-100 ℃ wide temperature control, with 1000 segment program capacity and +/- 0.1 ℃ temperature resolution, support automatic calculation and network monitoring functions.
Adopt cascade refrigeration system, Temperature range -40~ 150 ℃, humidity control range 20~ 98% RH, with 1000 segment program capacity and automatic calculation function, support PC link and network monitoring.
Adopt cascade refrigeration system, Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1 ℃, with 1000 segment program control and 15 safety detection functions, support remote monitoring.
The equilibrate refrigeration technology makes the temperature fluctuation small, equipped with fluorine-free R134 refrigerant to achieve energy saving and environmental protection, high temperature control accuracy and constant humidity, liner mirror stainless steel material is easy to clean and maintain, and the volume is 100L to meet the needs of various experiments.