Laboratory temperature instrument

Laboratory temperature instruments detect changes in environmental heat through sensors, converting physical signals into electrical signals to display numerical values. They are used to monitor laboratory environments, material storage, and temperature during reaction processes. They provide data support for constant temperature cultivation, drying oven calibration, and monitoring of paint curing.
Selection
When selecting, consider that the measurement range covers the usage scenarios, the accuracy matches experimental requirements, and the probe type is suitable for the measured medium. Pay attention to response speed and calibration cycles to ensure long-term stability. Prioritize corrosion-resistant materials and ensure interface compatibility with existing equipment.

Terms

Standards

Instruments

Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier, multi-wing air supply circulation, uniform temperature and humidity distribution, improve test reliability.

$ 6560.00

Microcomputer temperature and humidity controller, Temperature Fluctuation +/- 0.5 ℃, humidity fluctuation +/- 5% RH, with over-temperature protection, independent temperature limit alarm system to ensure safe and stable operation of the experiment.

$ 6691.00

Temperature range -30~ 150 ℃, humidity control 30~ 98% R.H., using PID control mode to ensure small temperature and humidity fluctuations, equipped with independent over-temperature protector and multi-layer sealing structure to improve test reliability and safety.

$ 12579.00

Adopt 7.0 inch Touchscreen controller, support 100 programs and 1000 cycles; high temperature and humidity control accuracy, temperature fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier and French Taikang Compressor to ensure stable and reliable testing.

$ 7222.00

Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Temperature Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H, with multi-wing air supply cycle to ensure uniform distribution, improve test reliability.

$ 11079.00

Temperature range -40~ 150 ℃, humidity control 30~ 98% R. H, Temperature Uniformity ≤ +/- 2 ℃, using PID control solid state relay and steam boiler humidification to ensure stable and reliable operation.

$ 12579.00

The mirror stainless steel liner is easy to clean, the TMHM equilibrating conditioning method controls temperature and humidity accurately, Temperature Fluctuation +/- 0.5 ℃, Humidity deviation +/- 3% RH, with independent temperature limit alarm system.

$ 5110.00

With -60~ 150 ℃ wide temperature control and 30~ 98% RH humidity range, using French Taikang Compressor and multi-wing air supply circulation to ensure uniform distribution of temperature and humidity and improve test reliability.

$ 10401.00

Temperature range -10~ 100 ℃, humidity control 35~ 95% RH, with independent temperature limit alarm system and multi-stage programmable PID controller to ensure safe operation and precise control of temperature and Humidity.

$ 3078.00

Using French Taikang fully enclosed Compressor, temperature and humidity control accuracy of +/- 0.1 ℃ and +/- 1% R.H., equipped with multi-wing air supply circulation system to ensure uniform temperature and humidity distribution in the test area and improve test efficiency.

$ 11482.00

Volume 12L, the highest temperature up to 1700 ℃, using silicon molybdenum Rod heating element, heating rate 10 ℃/min, temperature field Balance and temperature control accuracy +/- 1 ℃, with over-current protection and over-temperature alarm function.

$ 5721.00

Equipped with 7.0 inch Touchscreen controller, temperature and humidity control accuracy of +/- 0.1 ℃ and +/- 1% R.H., using French Taikang Compressor and multi-wing air supply circulation to ensure uniform temperature and humidity distribution in the test area and improve test efficiency.

$ 6560.00

Adopt microcomputer temperature and humidity controller, temperature uniformity +/- 1 ℃, humidity fluctuation +/- 5% RH, equipped with mirror stainless steel liner and observation window, support programmable control and multiple safety protection functions.

$ 4843.00

Using French Taikang fully enclosed Compressor, equipped with multi-wing air supply circulation system to ensure uniform distribution of temperature and humidity, Temperature Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2-3% R.H, improve test accuracy and efficiency.

$ 7754.00

300L high-capacity design, temperature uniformity up to +/- 1 ° C, humidity fluctuation of +/- 5% RH, equipped with intelligent Touchscreen controller and ultrasonic humidifier, supports programmable control and a variety of safety protection functions.

$ 2355.00

Articles

Application of Laboratory Scraper Heating Coating Machine in Hot Melt Adhesive Coating
This article introduces the application of a laboratory blade heating coating machine in hot melt adhesive coating. It first explains the coating process and principles, including three stages—heat conduction, fluid shear, and surface wetting—as well as the influence of temperature on adhesive viscosity.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.