Air-Jacketed Thermostatic Water Bath

The air constant temperature water bath heats water through electric heating tubes and uses a fan to circulate hot air to ensure uniform temperature inside the tank. It is used for constant temperature heating and reaction insulation of laboratory samples, such as maintaining temperature stability during viscosity testing of coatings.
Selection
When selecting, ensure the temperature range covers experimental requirements, temperature control accuracy meets standards, tank dimensions accommodate sample capacity, materials are corrosion-resistant and easy to clean, and safety protections include dry-burn prevention and over-temperature cutoff functions.

Terms

Standards

Instruments

Adopt diagonal air duct structure to ensure Temperature Uniformity +/- 1 ℃, Water-jacketed heating can still maintain thermostatic after power failure. Mirror stainless steel liner is easy to clean, with sound and light alarm and independent temperature limiting system to ensure experimental safety.

$ 843.00

Adopt diagonal air duct structure to ensure Temperature Uniformity +/- 1 ℃, Water-Jacketed heating can still maintain thermostatic after power failure, equipped with PID control and independent temperature limit alarm system to ensure the safe and stable operation of the experiment.

$ 1114.00

Water-jacketed structure with accurate and reliable temperature control, Temperature Uniformity +/- 0.2 ℃, can still maintain thermostatic for a long time after power failure, using mirror stainless steel studio and semi-circular design for easy cleaning.

$ 725.00

With water shortage and air burning function, Temperature Fluctuation +/- 0.3 ℃, Temperature range RT + 5~ 99 ℃, integrated sink and water Bath dual-use, easy to clean and safe operation.

$ 391.00

Water-jacketed heating method, Temperature Uniformity +/- 1 ℃, can still maintain thermostatic for a long time after power failure. The diagonal air duct structure in the box ensures uniform temperature, the mirror stainless steel liner is easy to clean, and the shelf spacing is adjustable for easy use.

$ 574.00

The water-jacketed structure has accurate and reliable temperature control, Temperature Uniformity +/- 0.2 ℃, and can still maintain thermostatic for a long time after power failure. The microcomputer PID controller has sound and light alarm function to ensure the safety and stability of the experiment.

$ 948.00

The water-jacketed structure has accurate and reliable temperature control, Temperature Uniformity +/- 0.2 ℃, and can still maintain thermostatic for a long time after power failure. The microcomputer PID controller has an automatic alarm function, and the studio is made of mirror stainless steel.

$ 462.00

Water-jacketed structure ensures uniform and stable temperature, and can still maintain thermostatic for a long time after power failure; High Accuracy Platinum Resistance Sensor, Temperature Fluctuation is only +/- 0.1 ℃, Uniformity +/- 0.2 ℃; with automatic water level alarm and over-temperature protection function.

$ 543.00

Temperature range RT + 5~ 99 ℃, Fluctuation +/- 0.3 ℃, set water Tank and Water Bath as a whole, one-time stamping forming stainless steel liner, with water shortage anti-air burning and independent temperature limit alarm system to ensure safe operation.

$ 341.00

Water-jacketed heating is used to ensure uniform and stable temperature, and it can still remain thermostatic for a long time after power failure; the circulating wind speed is automatically adjusted to avoid sample volatilization, and the Temperature Fluctuation is only +/- 0.3 ° C, with multiple safety alarm functions.

$ 638.00

Using Water-Jacketed heating technology, it can still maintain thermostatic for a long time after power failure; the circulating wind speed is automatically adjusted to avoid sample volatilization; the temperature control accuracy is +/- 0.3 ° C, the uniformity is +/- 0.5 ° C; it has multiple safety alarm functions.

$ 720.00

Water-jacketed Heating mode ensures Temperature uniformity +/- 0.5 ℃, and can still maintain thermostatic for a long time after power failure. With independent temperature limit alarm system, low water level automatically stops heating to ensure safe and stable operation of the experiment.

$ 572.00

Water-Jacketed heating is used to ensure uniform temperature and maintain thermostatic after power failure. With over-temperature protection, Sensor fault detection and water level monitoring functions, Temperature Fluctuation is controlled within +/- 0.5 ° C.

$ 699.00

Using Water-Jacketed heating technology, it can still maintain thermostatic for a long time after power failure, Temperature Uniformity +/- 1 ℃, equipped with diagonal air duct structure and PID control system to ensure stable and reliable experimental environment.

$ 638.00

Water-Jacketed heating is used to ensure uniform temperature, and it can still be thermostatic for a long time after power failure; the circulating wind speed is automatically adjusted to avoid sample volatilization; it has multiple Safety protection functions such as temperature, water level and door opening alarm.

$ 772.00

Articles

Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Hot air aging oven measures the long-term thermal-oxygen life of engineering plastics.
This article introduces how to use a hot air aging oven to test the long-term thermal-oxidative lifespan of engineering plastics. The test is based on the Arrhenius equation, which accelerates material aging at high temperatures to simulate performance changes under actual usage conditions.
Positive pressure method seal tester evaluates packaging pressure resistance
This article introduces how the positive pressure method sealing tester evaluates the pressure resistance of packaging. The instrument simulates actual pressure conditions by injecting compressed air into the packaging and then monitors pressure changes to determine if there is any leakage.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
Sheffield Smoothness Tester for Analyzing Paper Printing Surface
This article introduces how the Sheffield smoothness tester analyzes the printing surface of paper. The instrument quantifies paper smoothness by measuring the air leakage time, with a longer time indicating a smoother surface.
Schopper air permeability tester measures paper air permeability.
The Schopper air permeability tester measures the air permeability of paper based on Poiseuille's law, calculating the permeability by either the air flow rate under a constant pressure difference or the pressure difference at a fixed flow rate.
What is the difference between the Bendtsen method and the Gurley method for measuring paper air permeability using an air permeability tester?
The air permeability of paper is a key indicator for evaluating its structural compactness and suitability, especially crucial in fields such as packaging, filtration, and specialty papers. The Bendtsen and Gurley methods are two classic and widely used techniques for determining paper permeability.
What are the differences between a vacuum oven and a conventional oven?
The main difference between a vacuum oven and a conventional oven lies in their working pressure. Conventional ovens operate at atmospheric pressure, heating through air convection, making them suitable for routine drying tasks. In contrast, vacuum ovens are evacuated to low pressure to reduce air presence, primarily relying on thermal radiation for heat transfer. This makes them ideal for processing heat-sensitive, oxidation-prone materials or those requiring thorough drying.