Using electromagnetic force equilibrating Sensor, accuracy of 0.01mN/m, support platinum plate and platinum ring method, automatic measurement without calculation, real-time display Linear dispersion and save the results.
Measurement accuracy of 0.1mN/m using electromagnetic force equilibrating Sensor, support platinum plate method and platinum ring method dual method, automatic operation without manual calculation, real-time display Linear dispersion and save data.
Sensor using electromagnetic force equilibrating principle, Sensitivity and high accuracy, support platinum plate method and platinum ring method, automatic measurement without calculation, surface tension Measurement range 0~ 500mN/m, accuracy 0.01mN/m, real-time display Linear dispersion and preservation results.
Using platinum plate method or platinum ring method for measurement, with 0-600mN/m wide Measurement range and 0.01mN/m high resolution, standard error +/- 0.02mN/m, equipped with large-screen LCD display and real-time Linear dispersion analysis software, support platform slow and fast lift switching.
Sensor using electromagnetic force equilibrating principle, accuracy of 0.1mN/m, platinum plate method and platinum ring method, automatic measurement without calculation, real-time display Linear dispersion and save the results.
5-Inch color Touchscreen is easy to operate, Measurement range 0-48J covers a variety of gears, equipped with thermal printer and RS232 interface, steel structure design reduces test vibration energy loss.
Using Platinum Sensor to ensure linear stable measurement, Conductivity Detector cell constant K = 0.1, Glass shell corrosion resistance, suitable for 0~ 80 ℃ Operating temperature environment.
Using Platinum Sensor to ensure chemical inertness, CPS anti-clogging technology to extend the service life of 20 times, Glass rapid heat conduction, Measurement range +/- 2000mV, temperature -5~ 80 ℃.
Using Platinum ElectRode to Ensure Measurement Stability, Ceramic Sand Core Single Salt Bridge Design Improves Response Speed, Temperature range 0-70 ℃, Filler 3.0 mol/L KCl, Glass shell corrosion resistance.
With microwave ultrasonic separate and collaborative control function, using Platinum Resistance Sensor to achieve +/- 1 ℃ temperature control accuracy, equipped with 1800W adjustable ultrasonic Power and 1000W microwave output, support multi-stage program control and real-time response monitoring.
Using platinum black material to improve measurement Stability, Measurement range covers 2-20000μS/cm, Glass shell corrosion resistance, three-core aviation plug connection is reliable.
Using rectangular platinum ElectRode, the ElectRode force is 1.0N +/- 0.05N, the test voltage is adjustable from 100 to 600V, and the voltage drop does not exceed 10% when the short-circuit current is 1.0 +/- 0.1A. The dripping device can accurately control the dripping volume and time interval.
Using Platinum Sensor and Gel KCL Reference Solution, Operating temperature range is 0~ 60 ℃ to ensure stable reference potential and good sensing ability.
Using platinum sheet material, Conductivity Detector cell constant is 10, suitable for high conductivity environment water measurement, equipped with three core socket interface, no temperature compensation design.
Using Platinum ElectRode, Glass Shell Structure, Temperature range 0-50 ℃, Dimension 12 * 120mm, BNC connector to ensure stable connection.