Using dual-channel proportional value display, knob type operation is easy, flame size can be pre-selected, equipped with flameout protection device. Detection limit K ≤ 0.004mmol/L, Na ≤ 0.008mmol/L, Response Time < 8S, high stability.
Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, pass band is narrow, Sensitivity is high; Five elements can be combined with any combination at the same time, automatic ignition and flame monitoring, Response Time is less than 8 seconds, Stability change within 15 seconds ≤ 2%.
1KW standard blowtorch, flame height 170-190mm, support 0.1-999 seconds holding time setting, with automatic timing and high voltage ignition function, suitable for flame retardant performance testing of various cable materials.
The equipment adopts stainless steel structure to resist corrosion, equipped with automatic ignition and Timing function, combustion time 0~ 99.99 seconds, gas lamp Nozzle inner diaMeter 9.5mm, to ensure accurate and reliable testing.
Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, the passband is narrow, and the Sensitivity is high; the five elements can be combined with any combination of direct reading measurement at the same time, the Response Time is less than 8 seconds, and the relative change of Stability in 15 seconds does not exceed 2%.
Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, Sensitivity is high; Five elements can be combined with any combination of direct reading measurement at the same time, flexible and convenient; Internal standard channel can correct the signal to ensure stable and reliable performance.
Dual-channel proportional value shows that the sample suction and spray volume is less than 6mL/min, the Response Time is less than 8 seconds, and it has a flameout protection device, which is easy, stable and reliable to operate.
Dual channel LED digital display, Measurement accuracy, sodium detection limit ≤ 0.008mmol/L, support lithium calcium detection, using silicon Photocells, photovoltaic cells and liquefied petroleum gas fuel, sample volume is small and Sensitivity is high.
Using dual Sensor temperature measurement system, the maximum operating temperature is 380 ℃, Temperature range environment temperature to 380 ℃, support continuous work, large heating area and no open flame design.
Dual channel LED digital display ensures clear reading, using silicon Photocell, photovoltaic cell detection to make the measurement results accurate and stable, Response Time is less than 8 seconds and has flameout protection function, safe and reliable operation.
Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, pass band is narrow, Sensitivity is high; Support any combination of five elements direct reading measurement, Response Time is less than 8 seconds, Stability relative change within 15 seconds ≤ 2%.
Using concave Holographic grating design, Light spectrum pure and accurate, narrow passband, Sensitivity is high; Five elements can be combined with any combination of direct reading measurement at the same time, Response Time is less than 8 seconds, Stability relative change within 15 seconds does not exceed 2%.
Using concave Holographic grating design, Light spectrum is pure, narrow passband, Sensitivity is high, linearity is better; Support any combination of five elements while direct reading measurement, automatic ignition and flameout protection function to ensure safety.
Using concave Holographic grating spectroscopy, Light spectrum is pure and accurate, narrow passband, high Sensitivity, good linearity; supports any combination of five elements for direct reading measurement, Response Time is less than 8 seconds, Stability change within 15 seconds ≤ 2%.
The use of high-temperature non-alkali fiberglass insulation layer wOven into a hemispherical internal heating heater, heating area and heating up quickly, the highest temperature of 380 ℃, no open flame design to avoid bruising Glass ware.