Biochemical Low-Temperature Incubator

The biochemical low-temperature incubator maintains a low-temperature environment through a refrigeration system and simulates biological sample storage conditions with humidity control. It is used for microbial cultivation, enzyme reaction studies, and vaccine preservation, ensuring the stability of bioactive substances in the laboratory.
Selection
When selecting, pay attention to the temperature range and uniformity to match experimental requirements; check the volume and dimensions to accommodate the sample quantity; confirm the humidity control accuracy; consider energy consumption and noise indicators; and verify safety protection features such as over-temperature alarms.

Terms

Standards

Instruments

Using fluorine-free refrigeration system and mirror stainless steel liner, temperature range -40~ 65 ℃, with microcomputer intelligent control and independent temperature limit alarm function, support multi-stage programming and RS-485 communication interface.

$ 5245.00

With a wide range of -20~ 50 ℃ temperature control, temperature uniformity +/- 1 ℃, mirror stainless steel liner for easy cleaning, support low temperature compensation and RS485 interface connection, improve experimental accuracy and data recording convenience.

$ 4279.00

Mirror stainless steel liner for easy cleaning, temperature range -20~ 50 ℃, Temperature Fluctuation +/- 0.5 ℃, support low temperature compensation and RS485 interface connection, improve temperature control accuracy and data recording ability.

$ 1671.00

With -20~ 50 ℃ wide temperature control, temperature uniformity +/- 1 ℃, equipped with stainless steel liner and low temperature compensation function, support RS485 interface connection recording equipment to meet the needs of precision experiments.

$ 3448.00

With refrigeration and heating bidirectional temperature regulation function, Temperature range -20~ 60 ℃, mirror stainless steel liner to prevent atomization, support thermostatic fostering and tissue cell preservation.

$ 2757.00

With a wide Temperature range of -20~ 60 ℃ and +/- 1.5 ℃ Temperature Fluctuation, using high density fiberglass cotton insulation and forced convection circulation system to ensure uniform and stable temperature in the box, suitable for various foster experiments.

$ 979.00

Microcomputer intelligent LCD controller, Temperature Fluctuation +/- 0.5 ℃, Low Temperature +/- 1 ℃, Double door structure and mirror stainless steel liner for easy cleaning, support multi-stage programming and RS-485 interface connection.

$ 3217.00

With refrigeration and heating bidirectional temperature regulation function, Temperature range -60~ 60 ℃, volume 150L, mirror stainless steel liner and intelligent LCD display, support thermostatic fostering and tissue cell preservation.

$ 3814.00

High density fiberglass cotton insulation layer to ensure temperature stability, equipped with PT100 Platinum Resistance Sensor to achieve 0.1 ℃ resolution, thermal equilibrating temperature control with forced convection system to make the temperature field uniformity better.

$ 1134.00

High density fiberglass cotton insulation to ensure temperature stability, equipped with PID + SSR Control system to achieve +/- 1.5 ℃ Fluctuation, suitable for microbial foster and serum tests.

$ 2257.00

With refrigeration and heating bidirectional temperature regulation function, Temperature range -40~ 60 ℃, volume 150L, mirror stainless steel liner and intelligent LCD display, support thermostatic fostering and tissue cell preservation.

$ 2660.00

Temperature range -40~ 60 ℃, mirror stainless steel liner and fully enclosed imported Compressor ensure stable operation, suitable for a variety of scientific research scenarios.

$ 4582.00

Adopt high density fiberglass cotton insulation layer to ensure temperature stability, equipped with long axis fan forced convection system to make temperature Humidity uniform. Temperature control accuracy 0.1 ℃, Fluctuation +/- 1.5 ℃, support 1-9999 minutes timing function to meet the needs of precision experiments.

$ 1524.00

Temperature range -20~ 60 ℃, mirror stainless steel liner to prevent atomization, fully enclosed imported Compressor to ensure stable operation, volume 150L to meet various needs.

$ 1508.00

Adopt microcomputer intelligent LCD controller, Temperature Uniformity +/- 2 ℃, equipped with mirror stainless steel liner and environmentally friendly fluorine-free refrigeration system, support multi-stage programming and RS-485 interface, easy to operate complex experiments.

$ 3556.00

Articles

Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Constant temperature and humidity aging chamber for testing plastic yellowing according to GB/T 16422.3.
This article introduces the method of testing plastic yellowing using a constant temperature and humidity aging chamber in accordance with the GB/T 16422.3 standard. Yellowing is an indication of chemical degradation in plastics caused by heat, oxygen, and humidity.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
High-temperature aging chamber for testing thermal-oxidative aging of plastic films.
This article introduces the method of testing the thermo-oxidative aging of plastic films using a high-temperature aging chamber. Thermo-oxidative aging refers to the chemical changes that occur in plastics under high temperature and oxygen exposure, leading to a decline in performance.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Key Points for Selecting Low-Temperature Test Chambers in Rubber and Plastic Brittleness Temperature Testing
In the testing of brittle temperature for rubber and plastics, the selection of a low-temperature test chamber must ensure testing accuracy. When choosing the equipment, it is essential to consider various parameters comprehensively based on the requirements of the testing standards.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Safety Regulations for Closed Cup and Open Cup Methods for Testing the Flash Point of Coatings.
This article introduces two main testing methods for the flash point of coatings: the closed-cup method and the open-cup method. The flash point refers to the lowest temperature at which the vapor of a coating momentarily ignites upon encountering an open flame, serving as a critical indicator for assessing the risk of fire and explosion.
Tensile Testing Machine Evaluates High and Low Temperature Tensile Properties of Hot Melt Adhesive
This article introduces how to use a tensile testing machine to test the tensile properties of hot-melt adhesives at different temperatures. The performance of hot-melt adhesives varies with temperature: they may soften at high temperatures and become brittle at low temperatures.