Tack testing to assess adhesion by measurement of displacement or peeling time under specified weight. With thermostatic test chamber, multi-national standards are supported and the operation process is clear.
Temperature range -10~ 100 ℃, Temperature Stability +/- 0.02 ℃, using imported Compressor and SUS304 stainless steel heating device, support internal and external circulation, can accommodate 500ml beaker directly inserted into use.
The transparent vacuum chamber is sturdy and durable, and the automatic constant pressure air supply ensures the stability of the preset Vacuum Level. The range of Vacuum Level is 0~ -90KPa, and the test process is automatically completed with one-click operation, without the need for an external vacuum pump.
Using environmental refrigerant R134a, the cooling time is reduced by more than 40%, Temperature range -40~ 65 ℃, Temperature Fluctuation +/- 0.5 ℃, support multi-stage programming and independent temperature limit alarm, easy to operate and clean.
Temperature control accuracy of +/- 2 ℃, cooling capacity up to 3240W, equipped with fully enclosed Air-Cooled Compressor and anti-corrosion circulation system, rapid temperature rise and fall, support large capacity Bath and external circulation function.
Temperature range -20~ 20 ℃, cooling capacity up to 1800W, cooling time is reduced by 35% compared with traditional equipment, open Bath can be applied to acid solution and organic solution thermostatic experiment.
Temperature range -20~ 100 ℃, Temperature resolution 0.1 ℃, using TMHM equilibrating Conditioning method, temperature and humidity control accurate fluctuations, with 100 sets of program capacity and a variety of Safety protection functions.
Adopt mirror stainless steel liner and PID Control mode, Temperature range 0~ 60 ℃, Humidity deviation +/- 5~ 8% R.H., 99 cycle programs and independent temperature limit alarm system.
Temperature range -10~ 100 ℃, Temperature resolution 0.1 ℃, using programmable PID controller and TMHM equilibrating Conditioning method, temperature and humidity control accurate fluctuation is small, with independent temperature limit alarm system and a variety of Safety protection functions.
Temperature range -30~ 95 ℃, the use of Air-Cooled fully enclosed Compressor refrigeration, cooling fast low noise, the whole Tank foaming insulation, the inner Tank is made of stainless steel to ensure uniform and stable temperature.
Temperature range 10~ 85 ℃, humidity control 80~ 95% RH, fluorine-free environmental protection design, with independent temperature limit alarm system, mirror stainless steel liner easy to clean, Temperature resolution 0.1 ℃, stable and reliable operation.
Temperature range -5~ 80 ℃, Humidity deviation +/- 3% RH, mirror stainless steel liner and JAKEL circulating fan to ensure Temperature uniformity, support 99 cycle complex experimental procedures.
Adopt binary cascade refrigeration mode, temperature range -40 ℃ to 150 ℃, equipped with mirror stainless steel inner wall and automatic energy saving control system to ensure the test environment is stable and uniform.
Adopt multi-stage programmable PID controller and TMHM equilibrate Conditioning method, temperature control accuracy +/- 1.0 ℃, humidity control deviation +/- 3% RH, equipped with independent temperature limit alarm system, support 100 sets of programs 1000 cycle steps to ensure the stability and safety of the test process.
The equilibrated refrigeration technology makes the temperature fluctuation small, and the fluorine-free R134 refrigerant is more energy-saving and environmentally friendly. Temperature range 0~ 60 ℃, Humidity Control Range 50~ 90%, intelligent humidification system and mirror stainless steel liner.