Tape coating line Rod

Wire-wound drawdown bars are coating tools that transfer coatings onto substrates by forming uniform gaps through wound metal wires. Their function is to simulate industrial coating processes in the laboratory for testing coating thickness and uniformity. Applications include the preparation of coatings for tapes, labels, and films, aiding in the evaluation of coating performance.
Selection
When selecting a wire-wound rod for tape coating, consider the substrate type and the desired coating thickness. The wire diameter determines the coating amount: thicker wires are used for heavy coatings, while finer wires are suitable for thin coatings. Materials include stainless steel or plastic; stainless steel is durable, while plastic is ideal for single-use applications. The rod length should match the substrate width to ensure complete coating coverage. Clean the rod promptly after use to avoid residue affecting subsequent results.

Terms

Standards

Instruments

The adhesive force of the tape is 4.3N/cm, and the principle of cross-cut method is adopted, which is suitable for adhesion testing. The performance is stable and non-degumming, and the test results are accurate and reliable.

$ 166.00

Using the formed pRoduction process, Coating Weight is about twice that of the wire-wound coating Rod, wet film thickness is 13μm, film accuracy reaches 0.5 μm, and the material is 304 stainless steel.

$ 120.00

Equipped with 10-station synchronous test capability, 1000g weight and 1-999999 minute Timer, using SUS #304 steel plate to ensure test accuracy, and automatically recording tape peeling time.

$ 748.00

Wet film thickness 22.9 microns, diaMeter 9.52 mm, the forming Rod uses an extrusion process to process continuous grooves, with no wire breakage and easy cleaning; the wire-wound Rod is based on the traditional principle, and there are differences in coating amount.

$ 167.00

Using 2000g +/- 5g roller load and 300mm/min rolling speed to ensure that the adhesive tape sample is flat and evenly adhered to the standard substrate, in line with CNS-11888 and PSTC-8 design standards.

$ 524.00

11/16 inch standard width paper tape, capable of completing approximately 1800 cycles of testing per roll, must be stored at 23 +/- 2 ° C and 50 +/- 10% Humidity to ensure Stability.

$ 377.00

Using the formed pRoduction process, the wet film thickness is 6 microns, the accuracy is 0.5 microns, the cleaning is convenient and there is no worry of broken wire, to ensure the precision and durability of the coating prepative.

$ 120.00

Support bar and Drawdown blade double coating method, suitable for high, medium and low viscosity materials; coating speed 1~ 300mm/s stepless adjustable, Blade Coating accuracy +/- 3μm; equipped with innovative clamshell magnetic Drawdown blade and simple bar installation, easy to clean and load; Heating and Vacuum chuck function to improve Spreader mass.

$ 10562.00

Adopt replica tape method to measure surface roughness, Peak Measurement range 20~ 115μm, accuracy +/- 5μm, with automatic subtracting substrate function, High Protection Rating, anti-solvent and water dust.

$ 935.00

Wet film thickness 45μm, main Rod diaMeter 10mm, effective application width 600mm, using SUS304 material, Coating Weight, length and surface preparation can be customized, suitable for a variety of Spreader conditions.

$ 267.00

Support bar and Drawdown blade two coating methods, suitable for different viscosity materials. Equipped with heating and Vacuum chuck function, servo motor to ensure stable operation. Drawdown blade film thickness control accuracy is high, uniform film.

$ 6205.00

Tack is good and non-degumming, adhesion reaches 7.6 N/cm, mass performance is stable, suitable for cross-cut adhesion testing, to ensure accurate film integrity assessment.

$ 174.00

Employing an extrusion production process, the coating thickness is 105 microns, the coating width reaches 300 mm, and the coating accuracy can achieve 0.5 microns, ensuring coating uniformity and high-precision control.

$ 178.00

Using SUS304 stainless steel material, wet film thickness 52μm, main Rod diaMeter 10mm, effective application width 600mm, groove design can achieve accurate Coating Weight control.

$ 267.00

Measured value 500N, suitable for tape, PCB, adhesive tape and other materials disbonding force test, supporting the Force Gauge test bench.

$ 89.00

Articles

Application of Tensile Testing Machine in 180-Degree Peel Strength Test for Packaging Tape
This article introduces how a tensile testing machine is used to test the 180-degree peel strength of packaging tape.
Evaluation of Coating Adhesion Grade by Cross-Cut Tester Combined with Tape Method
This article introduces the method of evaluating coating adhesion using a paint film cross-cut tester combined with the tape method.
Cross-cut tester combined with adhesion test tape for evaluating coating peel-off.
The cross-cut test, paired with adhesion test tape, is a commonly used method for evaluating coating adhesion. It involves using a cross-cut knife to score a grid pattern on the coating surface, followed by the rapid peeling of specialized tape. The adhesion level is then assessed by observing the extent of coating detachment.
Standard Procedure for Cross-Cut Test of Ink Adhesion
The cross-cut test is a standard method for testing ink adhesion. It involves cutting a grid pattern on the coated surface, applying and then peeling off adhesive tape, and observing the extent of ink peeling to evaluate the adhesion grade.
Application of Initial Tack Tester in the Adhesive Products Industry
The initial tack tester is used to measure the adhesive force of adhesive products upon initial contact, which is important for the research, development, and quality control of products such as tapes and labels. It simulates the process of materials making contact and then separating, records relevant data, and helps evaluate performance.
Tensile testing machine tests the tensile strength of industrial tape.
This article explains how to use a tensile testing machine to test the tensile strength of industrial tapes. Tensile strength is a key indicator for measuring the mechanical properties of tapes, and testing must comply with international standards such as ISO and ASTM.
The 180-degree peel strength test for tape shows a 50% deviation in data due to misalignment of the sample.
In the 180-degree peel strength test of adhesive tape, if the sample is misaligned, the test data may drop by about half. This is because misalignment causes uneven force distribution during peeling, reducing the effective peel strength.