Outdoor temperature sensor

The outdoor temperature sensor detects changes in ambient temperature through a thermosensitive element, converting the physical quantity into an electrical signal output. It is used in fields such as meteorological monitoring, building HVAC systems, and agricultural greenhouses to achieve environmental temperature data collection.
Selection
When selecting, focus on ensuring the measurement range covers local extreme temperatures and the accuracy meets specific application needs. Consider that the protection rating is suitable for outdoor environments and the output signal is compatible with receiving equipment. Pay attention to the installation location, avoiding direct sunlight and heat source interference.

Terms

Standards

Instruments

Using split Sensor design, the temperature range covers -50~ 70 ℃, Humidity Measurement range 20%~ 99% RH, supports ℃/F unit conversion, which is convenient for indoor and outdoor environment monitoring.

$ 81.00

With +/- 0.2 ℃ High Accuracy, Support Bluetooth Wireless Setup and Data Download, Protection Rating up to IP67/NEMA6, Stable operation in harsh outdoor environments of -40~ 70 ℃.

$ 288.00

Measurement accuracy of 1% and automatic temperature compensation, 2 to 5 point calibrated and 500 data storage, suitable for outdoor environment with data stabilization and ElectRode diagnostics.

$ 770.00

With indoor and outdoor temperature measurement function, the range covers -50 ° C to 99 ° C, the humidity measurement accuracy reaches +/- 5% RH, the maximum and minimum temperature and humidity values can be recorded, and the base and wall mounting are supported.

$ 101.00

Capacitive polymer film Humidity Sensor and semiconductor temperature sensor, with temperature compensation and nonlinear correction function, can store 8000 sets of data, support USB connection and automatic calculation of average value, MAX Maximum and MIN Minimum, compact and easy to carry.

$ 294.00

Built-in High Accuracy Temperature Humidity Sensor, Temperature Error +/- 0.2 ℃, Humidity Error +/- 2.5%. Adopt Bluetooth low energy wireless transmission, support remote setting and data download, with weatherproof housing and NEMA6/IP67 Protection Rating, suitable for long-term outdoor monitoring.

$ 414.00

Built-in 10KΩ temperature sensor to achieve automatic temperature compensation, Measurement range 0-200.0mS/cm, plastic shell design durable and no reference solution, simplify the operation process.

$ 113.00

Temperature range of 50~ 120 ℃, irreversible discoloration, over-temperature grid window from white to red, clear contrast, suitable for indoor and outdoor equipment temperature display.

$ 140.00

With automatic temperature compensation function to ensure accurate pH and ORP measurement in the range of -20.0 - 120.0 ℃; waterproof design to adapt to outdoor humid environment, easy to operate and economical.

$ 706.00

Irreversible discoloration, the temperature range is 50~ 120 ℃, the number of temperature grids is 1 grid, after overheating, the grid window changes from white to red, the change is clear and strong contrast, suitable for indoor and outdoor equipment temperature measurement display.

$ 140.00

With 1 or 2 point Adjustment, support manual salinity and atmospheric pressure compensation, automatic temperature compensation to eliminate measurement deviation, extended memory can store 500 sets of data, Measurement accuracy of 0.2mg/L.

$ 482.00

Platinum Sensor ensures measurement Stability, built-in temperature sensor automatically senses sample temperature, ElectRode constant K = 1, Operating temperature range 0~ 60 ℃, suitable for a variety of instruments.

$ 106.00

Using Bluetooth low energy wireless transmission, easy to set up and download, Measurement range (temperature -40~ 100 ℃, Humidity 0-100% RH), high accuracy (temperature +/- 0.2 ℃), and has a weatherproof shell and visual alarm function, suitable for long-term outdoor monitoring.

$ 351.00

Measurement accuracy of 0.5% and automatic temperature compensation, 2 to 5 point calibrated and 500 data storage, backlit display and USB interface for outdoor use.

$ 696.00

Platinum Sensor ensures linear and stable measurement, built-in temperature sensor real-time compensation, Conductivity Detector cell constant K = 1, Low noise Shielding line design effectively reduces signal interference.

$ 140.00

Articles

Application of Laboratory Scraper Heating Coating Machine in Hot Melt Adhesive Coating
This article introduces the application of a laboratory blade heating coating machine in hot melt adhesive coating. It first explains the coating process and principles, including three stages—heat conduction, fluid shear, and surface wetting—as well as the influence of temperature on adhesive viscosity.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.