UV Transmittance Meter

The UV transmittance meter irradiates a sample with a UV light source and measures the ratio of transmitted light intensity to incident light intensity. It is used to assess the material's ability to transmit ultraviolet light, control UV protection performance in the coatings and inks industry, and evaluate UV blocking effectiveness in plastic packaging.
Selection
When selecting, consider matching the measurement wavelength range to application requirements, ensuring sample size compatibility with instrument fixtures, and meeting industry standards for measurement accuracy. Pay attention to dust and moisture prevention in the operating environment, and regularly calibrate with standard plates to ensure data reliability.

Terms

Standards

Instruments

It can simultaneously test infrared, ultraviolet and visible light transmittance, and support the evaluation of total solar energy barrier rate. Using point array color screen visual display, the fuselage is lightweight and portable, with real-time dynamic Adjustment, Measurement accuracy is better than +/- 2%.

$ 170.00

Effective application width up to 500mm, UV curing length 1000mm, using Touchscreen control, support 0-5m/min pRoduction speed, with tension control unwinding and adjustable UV UV light intensity 1-30mw/cm ² to ensure uniform curing.

$ 24279.00

Simultaneous measurement of UV energy, intensity and temperature, support four-band UV Power measurement, Data storage up to 60,000 Power data, high temperature design can run for a long time in 100 ℃ environment, sampling speed up to 2048 times/second.

$ 990.00

The three-in-one optical path design can simultaneously measure four sets of data, the test aperture of 1.3mm supports small-size material detection, with Automatic calibration and large-capacity storage functions. Measurement accuracy of +/- 2% ensures stable and reliable results.

$ 361.00

The three-in-one optical path measures the transmittance of three wavelengths at one time, the test aperture is 1mm to adapt to small-sized materials, and the parallel light design ensures stable measurement of thick materials, with an accuracy of +/- 2% and a resolution of 0.1%.

$ 361.00

Automatic correction of ABS value with one button, Light spectrum Bandwidth 4nm, Wavelength range 195-1000nm, 5-100mm Cuvette can be placed, Support Transmittance, Absorbance, concentration factor and other Operating Modes.

$ 816.00

PRoduction speed 0-5m/min, effective application width ≤ 300mm, using scraping with UV light curing, drying tunnel length of 1 Meter, with tension control unwinding and Touchscreen operation.

$ 16210.00

Adopt three-in-one parallel light path design, one measurement of visible light, infrared and ultraviolet transmittance; test aperture 1.3mm, suitable for small size and thick materials; Automatic calibration and large capacity storage function.

$ 361.00

With heating and UV curing functions, Spreader thickness is adjustable from 0 to 10mm, speed is 5 to 200mm/s, support Touchscreen control and a variety of customization options.

$ 8465.00

The minimum test aperture is 0.5mm, and the three Illuminants share a test hole. Three transmittance data of 550nm, 850nm and 940nm can be obtained for one hole. Real-time dynamic self-Adjustment, Test accuracy +/- 2%.

$ 538.00

It adopts parallel light path design, supports 47mm Film thickness material test, and can simultaneously measure ultraviolet 365nm, infrared 940nm and visible light transmittance. It has real-time self-calibrating function, and the operation is simple and fast to display three results.

$ 341.00

Application width up to 400mm, pRoduction speed 0-5m/min adjustable, UV light curing area 400 * 1000mm, main peak wavelength 365nm, equipped with tension control unwinding and Touchscreen Operating interface to achieve stable Spreader and rapid curing.

$ 14597.00

Adopt scraping method, equipped with 1 Meter Oven and UV light curing system, curing area 600 * 500mm, main peak wavelength 365nm, pRoduction speed 0-5m/min, with tension control unwinding to ensure uniform and stable Spreader.

$ 21051.00

One key automatic correction ABS value, Wavelength range 190~ 960nm, can be placed 5~ 100mm Cuvette, equipped with RS232 data output interface, support Transmittance, Absorbance, concentration factor and concentration direct reading Operating Mode.

$ 1058.00

Open measurement area supports vertical measurement, thickness ≤ 145mm sample compatibility, haze Repeatability ≤ 0.05%, providing transmittance compensation measurement and rich fixtures to adapt to different forms of samples.

$ 6496.00

Articles

Sensitivity Enhancement of Dark Box UV Analyzers in Thin-Layer Chromatography Fluorescence Detection
This article explores how to enhance the sensitivity of dark box ultraviolet analyzers in fluorescence detection for thin-layer chromatography. Sensitivity is influenced by factors such as light source stability, wavelength accuracy, sample background, and ambient light.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
UV aging test chamber for testing plastic weather resistance according to ISO 4892-2.
This article introduces the method of testing the weather resistance of plastics using a UV aging test chamber in accordance with the ISO 4892-2 standard.
UV spectrophotometer for measuring residual monomers in polymer solutions.
This article introduces a method for determining residual monomers in polymer solutions using ultraviolet spectrophotometry. The principle relies on the characteristic absorption of monomers in the ultraviolet region, calculating their content based on the relationship between absorbance and concentration.
Haze Transmittance Meter for Evaluating Optical Clarity of Contact Lenses
This article introduces how a haze transmittance meter is used to evaluate the optical clarity of visual correction products such as contact lenses. Haze refers to the blurriness caused by light scattering, while transmittance reflects the material's ability to transmit light. Together, these two factors determine clarity.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
UV Aging Test Machine Evaluates Outdoor Lifespan of Rubber
This article introduces how ultraviolet aging test chambers assess the service life of rubber in outdoor environments. Rubber exposed outdoors is affected by factors such as sunlight, temperature, and humidity, leading to a gradual decline in its performance.
Selection of UV Energy Meter: Matching Band Response with Energy Range
When selecting a UV energy meter, the key is to match two parameters: spectral response and energy range.
Transmittance Meter Selection Guide: Principles for Matching Light Sources and Samples
This article introduces how to select the light source for a transmittance meter based on sample characteristics. The types of light sources include halogen tungsten lamps, LEDs, and lasers, which are suitable for wide-band, monochromatic, or high-precision measurements, respectively.
Comparison between Xenon Arc Weathering Chambers and UV Aging Chambers in Weathering Evaluation
Comparison between Xenon Lamp Aging Test Chambers and UV Aging Test Chambers in Weathering Evaluation
UV aging test chamber for evaluating the discoloration degree of resin weather resistance
This article introduces the method of using a UV aging test chamber to examine the degree of weather-induced discoloration in resins.
Determination of Transmittance of Resin Solutions Using UV-Visible Spectrophotometer
This article introduces the method of measuring the transmittance of resin solutions using a UV-Vis spectrophotometer.
Rheometer combined with UV light source to study the curing behavior of photopolymerizable resin
This article introduces how to combine a rheometer with a UV light source to study the curing process of UV-curable resins.
UV aging test machine evaluates the UV resistance of ink.
This article introduces how to test the UV resistance of ink using a UV aging test chamber. The equipment accelerates aging by simulating ultraviolet light and controlling temperature and humidity, with key testing conditions including temperature, irradiance, and cycle time.
Xenon lamp aging test chamber for testing coating weatherability.
Xenon lamp aging test chambers accelerate the testing of weather resistance for materials such as coatings in the laboratory by simulating the ultraviolet, visible, and infrared portions of sunlight, while controlling conditions like temperature, humidity, and water spray.