Photoelectric Haze Meter

A photoelectric haze meter measures the ratio of transmitted light to scattered light intensity by illuminating a sample with a light source. It is used to quantify the haze value of transparent materials, reflecting the degree of light scattering. It is applied in the transparency testing of materials such as plastic films and glass.
Selection
When selecting, ensure the measurement range covers the haze range of the samples, with repeatability error less than 0.1%, and compliance with ASTM D1003 standards. Consider compatibility with sample thickness, and the calibration plate should come with a traceability certificate. The operation interface should be user-friendly, and the data export format should be compatible with the laboratory system.

Terms

Instruments

Using parallel illumination hemisphere scattering integrating sphere photoelectric reception mode, light transmitance measurement range 0-100%, haze measurement range 0-99%, with open sample window design, not affected by environment light.

$ 2629.00

Using parallel illumination hemispherical scattering integrating sphere photoelectric receiving mode, the accuracy of light transmitance and haze display is 0.01%, equipped with thin film magnetic fixture and liquid sample Cup, and supports 2000 sets of data storage.

$ 3882.00

Support haze and transmittance measurement, haze resolution of 0.01 units, Repeatability ≤ 0.1 units, open measurement area can be vertically operated, equipped with a variety of fixtures to adapt to different sample forms.

$ 11337.00

Using parallel illumination hemispherical scattering integrating sphere photoelectric receiving mode, the light transmitter and haze measurement accuracy are 0.01%, support U disk storage and USB communication, equipped with thin film magnetic fixture and liquid sample Cup.

$ 2888.00

Using parallel illumination hemispherical scattering integrating sphere photoelectric receiving system, the light transmitance haze accuracy is up to 0.01%, with A/C/D65 three light sources and vertical-lying dual-use observation mode, support USB interface data export, LED light source long life fast start.

$ 2010.00

Using 256 pixel dual array CMOS image sensor and concave grating spectroscopy, the haze Repeatability is less than 0.05, supports dynamic measurement and a variety of observation Illuminants to ensure accurate and reliable data.

$ 7464.00

Using 256 pixel dual array CMOS image sensor to achieve 0.01 unit haze resolution; Equipped with dynamic measurement function, real-time monitoring of environment changes to ensure data Reliability; Open measurement area supports vertical horizontal test.

$ 7464.00

Using 256 pixel dual array CMOS image sensor and concave grating spectroscopy, the haze Repeatability is less than 0.05, supports dynamic measurement and a variety of observation Illuminants to ensure accurate and reliable data.

$ 7464.00

Using 256 pixel dual array CMOS image sensor and concave grating spectroscopy to achieve High Accuracy Transmittance and haze measurement, Repeatability is less than 0.05, Support a variety of observation Illuminant and dynamic temperature monitoring.

$ 7464.00

Using 256-pixel dual-array CMOS image sensor and concave grating spectroscopy, the haze resolution reaches 0.01 units, supports dynamic measurement and open sample area, and adapts to the needs of different thickness sample testing.

$ 7464.00

Using 256-pixel dual-array CMOS image sensor and concave grating spectroscopy, the haze Repeatability is less than 0.05, and supports dynamic measurement and multiple observation Illuminants to ensure reliable data and adapt to different sample testing needs.

$ 7464.00

Open measurement area supports vertical measurement, thickness ≤ 145mm sample compatibility, haze Repeatability ≤ 0.05%, providing transmittance compensation measurement and rich fixtures to adapt to different forms of samples.

$ 6496.00

Using 360~ 780nm composite full Light spectrum LED Illuminant, equipped with 256 pixel CMOS Detector, measurement wavelength range of 360~ 780nm, interval of 10nm, to achieve haze, transmittance, chroma and other Optical inspection indicators of accurate testing.

$ 6980.00

Using 256 pixel dual array CMOS sensor and concave grating spectroscopy, haze Repeatability is less than 0.05, support dynamic measurement and a variety of chroma indicators, adapt to vertical or horizontal testing.

$ 7464.00

The PD array Detector meets the CIE V (lambda) 2 degree Visual Response, the haze Repeatability is within 0.15, and the open sample compartment supports vertical horizontal testing to adapt to different thickness samples.

$ 961.00

Articles

Standard Test Method for Measuring Optical Haze of Transparent Coated Films Using a Haze Meter
This article introduces the standard method for measuring the optical haze of transparent coated films using a haze meter. First, the instrument must be calibrated according to the standard, and the sample needs to be conditioned in a constant temperature and humidity environment. The measurement involves four steps, including air zeroing, measuring total transmission and scattered light flux, and finally calculating the haze value.
Haze meter measures light transmission and scattering in agricultural film.
This article introduces how a haze meter measures the light transmittance and the proportion of scattered light in agricultural films. Haze is the percentage of scattered light in the total transmitted light, while light transmittance is the ratio of transmitted light to incident light.
Application of Colorimeter and Color Matching Box in Pigment Color Inspection
A colorimeter and a light booth are two primary tools in pigment color inspection. The colorimeter measures color through photoelectric principles, while the light booth provides a standardized light source environment for visual evaluation of color effects, metamerism, and other phenomena.
Phosphor films and quantum dot coatings are uniformly applied using a coating machine.
This article introduces the significance of phosphor films and quantum dot coatings in optoelectronics and display technologies, highlighting that their performance depends on the uniformity, thickness, and density of the coatings.
Haze meter measures the haze and light transmittance of transparent coatings.
This article introduces the method of measuring the haze and light transmittance of transparent coatings using a haze meter. Haze refers to the degree of light scattering after passing through a material, while light transmittance reflects the amount of light directly transmitted.