High polymer material thickness Gauge

The high polymer material thickness gauge measures the thickness of materials non-destructively using physical methods such as ultrasound or eddy currents. Its principle is based on acoustic wave reflection or electromagnetic induction, and it is used to monitor the uniformity of coatings, films, and other materials. It enables real-time detection of thickness deviations on production lines for plastics and coatings.
Selection
When selecting, consider the compatibility of the material type with the probe technology, such as using ultrasound for non-metallic materials; ensure the measurement range covers the sample thickness; the accuracy must meet the requirements of process tolerances; the instrument should adapt to environmental factors like vibration and temperature on the production line; choose between portable or fixed types based on the usage scenario; and ensure calibration services are available to guarantee long-term stability.

Terms

Standards

Instruments

Measurement principle using ultrasonic, Measurement range 13~ 1000μm, accuracy +/- (2μm + 3%), suitable for wood, plastic and other substrates polymer Coating thickness detection.

$ 2652.00

Suitable for material measurement with temperature less than 350 ℃, with 5.0MHz Frequency and lower limit of pipe measurement Φ 25 * 3mm, to meet the needs of accurate thickness detection in high temperature environment.

$ 283.00

Measurement range 13-1000μm, accuracy +/- (3% H + 2) μm, non-destructive ultrasonic technology, resistance to solvents, acids, oils, water and dust, storage of 250 readings, support for USB connection and software updates.

$ 2855.00

Using 5MHZ Frequency and 14mm diaMeter design, support 3.0~ 200mm steel material measurement, minimum pipe diaMeter 30mm, suitable for high temperature environment, temperature measurement range of 450 ℃, to ensure accurate thickness detection.

$ 190.00

Suitable for 300 ℃ high temperature material thickness measurement, range 2.0~ 100mm, diaMeter 14mm, minimum diaMeter 30mm, 5MHz Frequency to achieve accurate measurement.

$ 199.00

Using bidirectional measurement technology, known sound velocity measurable Film thickness or known Film thickness measurable sound velocity, Measurement accuracy up to +/- (0.5% n + 0.05), support USB and Bluetooth data output, adapt to rough surface and paint measurement.

$ 592.00

Measurement range 0-4mm, contact pressure 100 +/- 10kPa, contact area 200mm ², with High Accuracy Indication Error +/- 0.0025mm, suitable for all kinds of sheet material thickness measurement.

$ 488.00

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

Measurement range 0~ 12.7mm, resolution up to 0.001mm, contact pressure 20 +/- 0.5Kpa to ensure measurement Stability, suitable for all kinds of sheet material thickness detection.

$ 543.00

Measurement range 0-20mm, accuracy 0.01mm, contact pressure 20 +/- 0.5kPa, contact surface diaMeter 35.7mm, suitable for a variety of sheet material thickness detection, to ensure high parallelism and Precision.

$ 493.00

Measurement range 0-20mm, accuracy 0.001mm, contact pressure 20 +/- 5kPa, suitable for paper, Cardboard and sheet material Film thickness detection, in line with a number of international standards.

$ 401.00

Measurement range 0.8~ 300mm, accuracy up to +/- 0.04mm, support high-speed measurement 10 times/second, portable design for field use.

$ 706.00

Spreader width 100mm, wet film thickness 200μm, high-quality wear-resistant corrosion-resistant alloy steel material, can be manually or automatically film, support non-standard customization, suitable for a variety of material coating preparatory and performance testing.

$ 143.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Friction and wear testing machine evaluates the wear resistance of self-lubricating polymer materials.
This article introduces how to use a friction and wear testing machine to evaluate the wear resistance of self-lubricating polymer materials. It explains the working principles of the testing machine, including the basic formulas for measuring the friction coefficient and wear rate.
Thermogravimetric Analyzer for Measuring Moisture and Volatiles in Polymer Materials
Thermogravimetric analyzers determine the moisture and volatile content in polymer materials by measuring the mass changes during the heating process.
Mechanical thickness gauge for measuring film thickness uniformity.
The mechanical thickness gauge assesses the uniformity of film thickness through contact measurement. During measurement, the probe contacts the sample under standard pressure, converting displacement into a thickness reading.
The film applicator applies hydrocolloid adhesive onto medical dressings.
The coating machine is used to apply a hydrocolloid adhesive evenly onto the substrate of medical dressings. This adhesive, made from hydrophilic polymer materials, maintains its adhesion and comfort in moist environments.
Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Application of Electrolytic Thickness Tester in Quality Control of Precision Electroplating Layers
The electrolytic thickness gauge measures coating thickness through the principle of electrochemical dissolution, calculating based on Faraday's law, offering high accuracy and independence from calibration.
Ultrasonic Thickness Gauge Measures the Thickness of Flexible Packaging Materials
This article introduces the principles, technical points, and operational procedures for measuring the thickness of flexible packaging materials using an ultrasonic thickness gauge. It is based on the principle of ultrasonic pulse reflection, which calculates thickness by measuring the propagation time of sound waves through the material.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.