The high-temperature air compressor uses a motor to drive the compression components, compressing air into a high-temperature and high-pressure state. After treatment by the cooling system, it outputs stable compressed air. It is used for supplying air sources to industrial equipment, powering spraying systems, and operating in high-temperature environments.
Selection
Select the exhaust volume based on the actual gas consumption, match the working pressure range, consider the temperature resistance of the cooling system, check the insulation grade of the motor, confirm the corrosion resistance of the equipment materials, and make the selection in combination with installation space and energy consumption.

Terms

Standards

Instruments

Temperature range -40~ 130 ℃, Temperature Fluctuation ≤ +/- 0.5 ℃, using imported Air-Cooled fully enclosed refrigeration Compressor, with grounding protection, over-temperature protection, refrigerator overpressure overload protection and other functions.

$ 5187.00

Imported Air-Cooled fully enclosed refrigeration Compressor, Temperature range -80~ 130 ℃, temperature fluctuation ≤ +/- 0.5 ℃, with over-temperature protection, grounding protection and other multiple safety functions.

$ 6860.00

Temperature range -5~ 95 ℃, using Air-Cooled fully enclosed Compressor, high cooling efficiency and low noise, the whole Tank foamed insulation, the inner Tank is made of stainless steel, PID automatic temperature control accuracy.

$ 2244.00

Adopt 7-inch Touchscreen control, equipped with French Taikang Compressor unit, Temperature Fluctuation ≤ +/- 0.5 ℃, multi-wing air supply cycle to ensure uniform temperature, in line with GB2423 and other standards.

$ 5495.00

Adopting environmentally friendly Compressor refrigeration system, Temperature Uniformity up to +/- 0.05 ℃, Equipped with High Accuracy PID temperature control and multiple Safety protection devices to ensure stable and reliable experimental process.

$ 4805.00

Adopting a pure oil-free lubrication piston system, the noise value is only 59dB, and it is equipped with a 60L anti-rust treatment gas storage Tank. The air pressure can be adjusted within the range of 5-8Bar, and it has multiple automatic protection functions.

$ 1042.00

Temperature range -20~ 95 ℃, Tank size 350 * 350 * 220mm. Using continuous PID automatic control and Air-Cooled fully enclosed Compressor, cooling fast and low noise, the inner Tank is made of stainless steel, good thermal insulation performance.

$ 2111.00

Air Compressor can reduce the working noise to about 43 decibels, the sound is extremely low, to meet the needs of various indoor environments for quiet operation.

$ 1655.00

The noise is as low as 52dB during operation, the pure oil-free lubrication piston system ensures clean gas, the exhaust volume is 155L/min, the pressure is 8bar, the cylinder liner adopts Nano coating technology to improve the life, and the automatic design realizes energy saving and power saving.

$ 493.00

Using reciprocating design, Power 2400W, exhaust capacity 465L/min, working noise as low as 53dB, with multiple automatic protection systems, no need for oil lubrication, high gas cleanliness.

$ 1574.00

Large diaMeter centrifugal wind wheel and optimized air supply circulation duct, heat flow evenly, Temperature Fluctuation +/- 2%, Temperature range RT + 5~ 250 ℃, can work continuously for a long time, high stoving efficiency.

$ 762.00

Adopt piston structure, running Power 550W, noise value 58dB, with pure oil-free design, output gas clean, air pressure adjustable range 5-8Bar, automatic start-stop protection, service life of more than 15,000 hours.

$ 606.00

Adopting oil-free piston compression technology, the exhaust pressure is 8 Bar, the exhaust volume is 1500L/min, and the noise is only 72dB. It is equipped with a 330L air storage Tank and an automatic pressure switch to ensure a stable air supply.

$ 2252.00

Adopt environmentally friendly Compressor refrigeration and non-heat centrifugal circulation pump, Temperature range -20~ 160 ℃, Temperature Uniformity +/- 0.05 ℃, equipped with large-screen LCD display and safety protection device to ensure that the temperature field is highly uniform.

$ 1997.00

Temperature range -5~ 95 ℃, pump flow rate of 15L. Using microcomputer precision thermostatic control system and Air-Cooled fully enclosed Compressor, high cooling efficiency, low noise, the overall foaming and heat insulation performance of the Tank body is good.

$ 1397.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Hot air aging oven measures the long-term thermal-oxygen life of engineering plastics.
This article introduces how to use a hot air aging oven to test the long-term thermal-oxidative lifespan of engineering plastics. The test is based on the Arrhenius equation, which accelerates material aging at high temperatures to simulate performance changes under actual usage conditions.
Melt flow index tester measures the processing fluidity of high-temperature engineering plastics.
This article introduces how a melt flow indexer measures the processing fluidity of high-temperature engineering plastics. It first explains the working principle of the instrument, which involves measuring the rate at which molten plastic passes through a standard die under specific temperature and pressure conditions to obtain the melt flow rate value.
High-temperature aging chamber for testing thermal-oxidative aging of plastic films.
This article introduces the method of testing the thermo-oxidative aging of plastic films using a high-temperature aging chamber. Thermo-oxidative aging refers to the chemical changes that occur in plastics under high temperature and oxygen exposure, leading to a decline in performance.
Key Parameters for Air Compressor Selection and Analysis of Energy Efficiency Standards
The selection of an air compressor requires comprehensive consideration of discharge pressure, discharge volume, drive power, and the characteristics of the compressed medium to meet actual air usage requirements.
Humidity and heat test chamber tests the moisture absorption rate of resin under high temperature and high humidity conditions.
This article introduces the method of using a hygrothermal test chamber to measure the moisture absorption rate of resin under high temperature and high humidity conditions.