Non-destructive coating thickness Gauge.

Non-destructive coating thickness gauges measure the thickness of coatings on substrates by detecting changes in electromagnetic fields generated when the probe contacts the coating, using magnetic induction or eddy current principles. They are used for measuring the thickness of paint or plating layers on metal or non-metal substrates, providing direct readings in fields such as automotive painting and electronic plating.
Selection
When selecting, ensure the substrate type matches the magnetic induction or eddy current principle: use magnetic induction for iron-based materials and eddy current for non-ferrous metals. Consider the coating thickness range and accuracy, and choose a small probe for curved surface measurements. Portable devices are suitable for on-site use, while fixed types are ideal for assembly lines. Environmental temperature and substrate flatness affect measurement stability.

Terms

Instruments

Using photothermal method to achieve non-destructive measurement, Measurement range 0-300μm, accuracy +/- 3%, can be measured in any shape of the sample including the frame and edge.

$ 25028.00

Measurement accuracy with professional calibrating services for quality control and equipment maintenance, purchased with Coating thickness Gauge.

$ 154.00

Measurement range 13-1000μm, accuracy +/- (3% H + 2) μm, non-destructive ultrasonic technology, resistance to solvents, acids, oils, water and dust, storage of 250 readings, support for USB connection and software updates.

$ 2855.00

Measurement range 50-3800 microns, ASTM D6132 and ISO 2808 compliant, non-destructive ultrasonic technology, Sensitive Sensor and Wear Resistant Probe support for multi-Probe replacement.

$ 3117.00

Using magnetic Induction principle, automatically identify magnetic metal substrate, high wear-resistant carbide Probe service life of more than 500,000 times, with zero point, single point, five point Adjustment, can store 1600 measurement data and connect to computer software.

$ 311.00

Adopt split Probe, Frequency 5MHz/2.5MHz, Measurement range 1.2-225 mm, support Speed of sound back measurement and Data storage functions, suitable for a variety of material thickness detection.

$ 242.00

Measurement of thick soft coatings such as polyurea and asphalt, thickness range 50 to 7600 μm, storage of 100,000 readings, ASTM D6132 compliant, non-destructive ultrasonic technology, durable and easy to operate.

$ 3987.00

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

Using ultrasonic technology implementation nondestructive measurement, Measurement range 13~ 1000μm, accuracy +/- 3%, support multi-coating system analysis, with weatherproof protection and a variety of data transmission methods.

$ 2855.00

Using ultrasonic technology nondestructive measurement, up to 3 layers of coating system measurement range 50~ 3800 μ m, error +/- 3%, with weatherproof design and high capacity Data storage function.

$ 3724.00

Measurement range 13-1000μm, accuracy +/- 3%, weatherproof design, support for multi-layer coating system analysis, data storage capacity up to 100,000 Measured values.

$ 3462.00

Measured value 500N, suitable for sheet, block material push-pull and destructive force test, can be used with Force Gauge test stand.

$ 130.00

Using magnetic Induction and eddy Current principle simultaneous measurement composite coatings, Measurement range 0~ 1500μm, error +/- 1%, can display a single coating and zinc layer thickness, suitable for the accurate detection of ferrous and non-ferrous substrates.

$ 1622.00

Articles

Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
Standard Operating Procedure for Zero Calibration and Substrate Calibration of Coating Thickness Gauges
This article introduces two key calibration methods for coating thickness gauges: zero-point calibration and substrate calibration. During operation, it is important to ensure that the probe is perpendicular, pressure is applied evenly, and regular calibration and recording are maintained. These steps effectively enhance measurement accuracy and meet industry standard requirements.
Differences in Measurement Principles Between Magnetic Method and Eddy Current Method for Coating Thickness Gauges
Coating thickness gauges primarily utilize two measurement principles: magnetic method and eddy current method. The selection of the method should be based on the characteristics of the substrate material to ensure measurement accuracy.
What is a Coating Thickness Gauge? A Complete Analysis of Its Principles, Usage, and Application Areas
The article systematically elaborates on the working principles of two core measurement techniques, magnetic induction and eddy current, detailing the standard measurement process from calibration to data recording, and conducting an in-depth analysis of the influence of substrate characteristics, geometric shapes, and environmental factors on measurement accuracy.