The pressure-sensitive element is used for automatic counting, the diaMeter of the culture dish supports ≤ Φ 90 mm, and it is equipped with dark deep background and annular fluorescent side-shot lighting. The colony contrast is clear, and the counting is fast and reliable.
Irreversible discoloration design, temperature accuracy 50 ℃, circular single grid structure, specification 2x2cm, Pressure sensitive adhesive to ensure firm paste, suitable for temperature monitoring in harsh environments.
The irreversible discoloration feature ensures that the temperature record is permanently preserved, the 75 ° C accurate temperature measurement point is firmly pasted with the Pressure sensitive adhesive, the 2x2cm round design is easy to install and the protective film enhances the durability.
Manual control of holding pressure is easy to operate, 15mm thick Organic Glass sealing bucket enhances compressire strength, Vacuum Level range -90~ 0kPa, resolution accurate to 0.1kPa, built-in time display automatic timing clear.
Tack testing to assess adhesion by measurement of displacement or peeling time under specified weight. With thermostatic test chamber, multi-national standards are supported and the operation process is clear.
Six-station synchronous test, timing accuracy of 99 hours 59 minutes 59 seconds, using imported proximity switch and laser cross-cut test board to ensure accurate and reliable data, with automatic timing and anti-data loss function.
With 6 test stations can synchronize multiple sets of tests, High Accuracy proximity switch and laser cross-cut test board, timing range of 9999h59min59s, automatic Timing function to ensure accurate and reliable data.
Manual pressure control pressure holding operation is simple, electronic pressure holding device reduces mechanical abrasion, pressure range 0~ -90kPa, accuracy +/- 0.1kPa, Organic Glass sealing barrel wall thickness 15mm to enhance compressive strength.
With 5 groups of independent testing capabilities, the temperature control range is from room temperature to 70 ° C, and the hot air circulation method is used to ensure Temperature uniformity.
Measurement accuracy of 0.007mm, Graduation of 0.001mm, probe diaMeter Φ 5mm, maximum measurement depth 45mm, suitable for on-site rapid thickness detection.
Measurement accuracy of 0.007mm, Graduation of 0.001mm, probe diaMeter of Φ 5mm plane, maximum measurement depth of 80mm, in line with national standards.
Using irreversible discoloration technology, with three temperature windows, Temperature range 70 ℃ to 120 ℃, Back Pressure sensitive adhesive design is easy to paste, size is 12x30mm.
Automatic counting using pressure sensitive elements, equipped with special probe pen and dark background lighting, culture dish diaMeter support ≤ Φ 90mm, fast and reliable counting and clear colony contrast.
Using 2000g +/- 5g roller load and 300mm/min rolling speed to ensure that the adhesive tape sample is flat and evenly adhered to the standard substrate, in line with CNS-11888 and PSTC-8 design standards.
Using irreversible discoloration technology, temperature point 60 ℃, specification 2x2cm circular design, with Pressure sensitive adhesive to ensure firm paste, over temperature display red, black and other Color changes.