Low-frequency signal penetration depth of 20mm, can simultaneously measure concrete carbide moisture content and plaster moisture content, built-in environment Sensor, support a variety of professional probe expansion measurement function.
4 groups of samples can be tested at the same time, using PID precise temperature control technology, Temperature range from room temperature to 1000 ℃, with automatic calculation of carbon black content and ash content function, open lid structure heat dissipation effect is better.
Conductivity Detector measurement principle, measurement range 0~ 84%, resolution 0.1%, Response Time 1 second, with temperature and humidity compensation function, portable design weight only 203 grams.
Sharp probe measurement without leaving marks, measurement range 6%~ 90%, support wood moisture content and wood humidity equivalent value display, equipped with extended Probe and hammer ElectRode for different depth measurement.
Measurement unit with Baume degree, sugar content accuracy +/- 0.1 ° Baumé, automatic temperature compensation, 1.5 seconds fast display results, only 2 drops of sample, waterproof design for a variety of environments.
Using computer technology to ensure accurate measurement, the measurement range is 0~ 50%, the resolution is 0.1%, and the moisture content and Ambient Temperature can be measured at the same time.
4 groups of samples can be tested at the same time, using PID temperature control accuracy of 0.1 ℃, support segmented program heating, one key automatic calculation of carbon black and ash content, open the lid structure heat dissipation fast.
Using imported cold light source and narrow-band interference technology, the detection limit is 0.05mg/L, supports continuous measurement and standard Measurement mode, and the built-in large-capacity lithium battery can store 4000 sets of data.
The thermal weight loss method is used to measure carbon black content, the operating temperature can reach 990 ° C, and the 7-inch Touchscreen is equipped to realize one-button calculation, support segmented paraMeter setting, and the Furnace body separation design has better heat dissipation.
The fat content was determined by Soxhlet extraction principle, the measurement range was 0.5% -60%, and two samples could be processed at the same time.
Conductivity Detector measurement principle, measurement range 0~ 95%, resolution of 0.1%, Response Time of only 1 second, with temperature compensation and automatic shutdown function, portable design weight of about 175 grams for on-site use.
It can measure refractive index 1.3000~ 1.7000nD and sugar content 0~ 100% Brix, with accuracy of +/- 0.0002nD and +/- 0.1% Brix, respectively, and supports temperature correction and direct data printout.
Conductivity Detector measurement principle, measurement range 0-80%, resolution 0.1%, Response Time 1 second, with temperature and humidity compensation and backlight display, easy to quickly detect on site.
Platinum Sensor provides linearly stable measurement results, Conductivity Detector cell constant K = 10, Measurement range 0 to 200mS/cm, suitable for high Conductivity Detector liquid detection.
Using electromagnetic wave scanning technology, high frequency scanning depth 50mm, Measurement range 0-99.9%, Response Time 1 second, no contact can be measured without damage to the internal moisture content of the object.