Powder Conductivity Measurement Pen

The powder conductivity test pen applies voltage to measure current value through electrode contact with powder samples and calculates conductivity. It is used to detect the electrostatic characteristics of powders, controlling production safety and preventing static accumulation in the coatings and plastics industries.
Selection
When selecting a powder conductivity test pen, consider the measurement range matching the powder type, accuracy meeting standard requirements, electrode material being wear-resistant, simple operation and easy maintenance, environmental adaptability such as temperature and humidity effects, to ensure long-term stable use.

Terms

Standards

Instruments

Special design container to ensure measurement conformity, suitable for color scheme, suitable for fine powder particle measurement, effectively avoid the influence of powder tightness and surface Smoothness.

$ 220.00

With conductivity 0~ 19.99mS/cm Measurement range, accuracy +/- 1.0%, support TDS conversion factor and temperature compensation settings. Platinum-plated black ElectRode reduces Polarization effect, IP67 Protection Rating is suitable for use in a variety of environments.

$ 155.00

Platinum Sensor ensures fast and stable measurement, supports 1-3 point calibrate and 0.1-1 adjustable TDS conversion factor, with automatic temperature compensation and end point locking function, Measurement range covers 0-20mS/cm conductivity and 0-10ppt salinity.

$ 165.00

Platinum ElectRode ensures fast and stable measurement, supports 1-3 point calibrating and automatic temperature compensation, salinity Measurement range 0-80ppt, conductivity covers 100μS/cm to 200mS/cm, with automatic end lock and fully waterproof design.

$ 167.00

Combined ElectRode can simultaneously measure pH, conductivity, TDS, salinity and temperature, support one-button switching paraMeters; Conductivity Detector ElectRode platinum black to reduce Polarization effect, accuracy of +/- 0.01pH; with automatic temperature compensation and IP67 dustproof and waterproof design.

$ 213.00

Conductivity Detector cell constant K = 0.1, built-in temperature sensor real-time sensing sample temperature, suitable for low Conductivity Detector liquid measurement.

$ 314.00

Measurement range 0~ 199μS/cm, automatic temperature compensation 0~ 50 ℃, waterproof shell design, ElectRode replaceable, easy to carry and operate.

$ 101.00

With multi-range measurement function, covering the range of 0-20mS/cm, using Platinum Sensor to ensure fast and stable measurement, support 1-3 point calibrating and automatic temperature compensation, fully waterproof design for use in harsh environments.

$ 156.00

Measurement range 0-2μS/cm with Mini-DIN 8 core connector for accurate detection of low conductivity solutions.

$ 199.00

Standard funnel method for metal powder flowability measurement, equipped with 2.5mm and 5mm pore diaMeter stainless steel funnel, can accurately measure 50g powder flow time to +/- 0.01s, suitable for powder testing such as cemented carbide.

$ 525.00

Platinum Sensor provides linearly stable measurement results, Conductivity Detector cell constant K = 10, Measurement range 0 to 200mS/cm, suitable for high Conductivity Detector liquid detection.

$ 106.00

Can test flowability, Angle of Peace and Loose Bulk Density, equipped with 30ml stainless steel measuringflask and double powder plate, funnel diaMeter can be selected 5mm or 2.5mm, for precise control of powder mass.

$ 993.00

Supports dual paraMeter measurement of conductivity salinity, Measurement accuracy up to 0.5% F. S, with automatic temperature compensation and ElectRode diagnostic functions, can store 500 sets of data and comply with GLP specifications.

$ 323.00

Platinum ElectRode Sensor ensures fast and stable measurement, supports 1 to 3 point calibrating and automatic temperature compensation, Measurement accuracy of +/- 1% F. S, with automatic end point locking and full waterproof performance.

$ 160.00

Platinum Sensor ensures linear and stable measurement, built-in temperature sensor real-time compensation, Measurement range of 0-200mS/cm, suitable for high Conductivity Detector liquids, equipped with 5 Meters low noise Shielding cable.

$ 140.00

Articles

High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Hall flowmeter measures the flowability of spray powder
This article introduces how a Hall flowmeter measures the flowability of spray powder. It uses a standard funnel to measure the time required for a certain mass of powder to flow out under gravity—the shorter the time, the better the flowability.
Tap density tester evaluates the accumulation characteristics of sprayed powder.
This article introduces how to use a tap density tester to evaluate the packing characteristics of spray powders. The tap density tester simulates vibration to densely pack the powder and measures the mass per unit volume, thereby obtaining the tap density.
Laser particle size analyzer measures the particle size distribution of spray powder.
Laser particle size analyzers measure the particle size distribution of sprayed powder based on the principle of light scattering, which is critical for coating uniformity and adhesion. During measurement, the powder must be dispersed in a suitable medium to avoid agglomeration, and tests should be repeated to ensure accuracy.
Conductivity meter measures the conductivity of water extract from pulp.
This article introduces the method of measuring the electrical conductivity of pulp water extracts using a conductivity meter. Electrical conductivity reflects the content of soluble ions in pulp, which is used to evaluate washing effectiveness and the impact of water quality.
Sand Falling Test Apparatus for Measuring the Wear Resistance of Powder Coatings
The sand falling test instrument determines the wear resistance of powder coatings by simulating sand particle impact. During the test, abrasive material falls vertically from a specified height, continuously scouring the coating until the substrate is exposed. The wear resistance is evaluated based on the mass of abrasive material consumed.
Impact testing machine tests the impact resistance of powder coatings.
This article introduces the method of testing the impact resistance of powder coatings using an impact tester. The test simulates instantaneous impact through a falling weight or pendulum hammer, following ISO or ASTM standards.
Pendulum hardness tester measures the damping hardness of powder coatings.
This article introduces the method of testing the damping hardness of powder coatings using a pendulum hardness tester. The test is based on the principle of energy attenuation, where the hardness is reflected by the time it takes for the amplitude of the pendulum to decay as it swings on the coating surface, with a longer time indicating a harder coating.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
Conductivity meter detects ion impurity content in coatings.
This article introduces the method of using a conductivity meter to detect the content of ionic impurities in coatings. The principle involves measuring the conductivity of the coating solution to indirectly assess the total amount of ionic impurities, as conductivity is related to ion concentration. The detection steps include sample preparation, instrument calibration, measurement, and data analysis.
How does the instrument calculate total dissolved solids in water from conductivity?
This article explains how TDS instruments estimate total dissolved solids by measuring the electrical conductivity of water. Since most dissolved solids exist in ionic form, which affects conductivity, there is a correlation between the two.
Density Determination: Selection Strategy between Pycnometer Method and Densimeter Method
This article introduces two methods for measuring the density of substances: the pycnometer method and the densimeter method. The pycnometer method calculates density by measuring the mass of a sample of fixed volume. It is suitable for measuring liquids, powders, and small granular solids, offering high precision but slower operation, and requires temperature control.
Salt spray test chamber evaluates the protective performance of powder coatings
The salt spray test chamber accelerates the evaluation of the corrosion resistance of powder coatings by simulating a salty and humid environment. The test is based on electrochemical principles, where salt spray penetrates coating defects and initiates corrosion of the metal substrate. During operation, parameters such as temperature and sedimentation rate must be strictly controlled, and standards such as ISO and ASTM must be followed.