Rapid Temperature and Humidity Chamber

The rapid temperature and humidity chamber simulates rapid temperature changes and humid environments inside the chamber through its refrigeration, heating, and humidity control systems. It is used to test the resistance of materials under alternating temperature and humidity conditions, commonly applied in reliability verification for electronics, automotive components, and coatings.
Selection
Focus on the temperature change rate range, temperature and humidity control accuracy, chamber volume, and compatibility with sample racks when making a selection. Verify the long-term operational stability, energy consumption data, and after-sales maintenance cycle of the equipment to ensure it matches the working condition parameters required by actual testing standards.

Terms

Standards

Instruments

Using French Taikang fully enclosed Compressor, temperature and humidity control accuracy of +/- 0.1 ℃ and +/- 1% R.H., with 100 program capacity and rapid temperature change performance, suitable for harsh environment testing.

$ 9755.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -60~ 150 ℃, humidity control 30~ 98% RH, multi-wing air supply circulation and independent refrigeration system, uniform temperature and humidity distribution, low failure rate.

$ 13209.00

Inner Chamber dimensions 800 * 1000 * 1000mm, temperature range -20~ 150 ℃, humidity range 30~ 98% R.H., using French Taikang Compressor and multi-wing air supply circulation, uniform temperature and humidity distribution, high control accuracy.

$ 9191.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -40~ 150 ℃, humidity control 30~ 98% RH, using French Taikang Compressor and multi-wing air supply circulation system to ensure uniform and stable distribution of temperature and humidity.

$ 12531.00

Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier, multi-wing air supply circulation, uniform temperature and humidity distribution, improve test reliability.

$ 6560.00

Temperature range -10~ 100 ℃, humidity control 35~ 95% RH, with independent temperature limit alarm system and multi-stage programmable PID controller to ensure safe operation and precise control of temperature and Humidity.

$ 3078.00

Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Temperature Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H, with multi-wing air supply cycle to ensure uniform distribution, improve test reliability.

$ 11079.00

Using 7.0 inch Touchscreen and French Taikang Compressor, temperature range -20~ 150 ℃, humidity range 30~ 98% R.H., with multi-wing air supply circulation and automatic calculation function to ensure uniform distribution of temperature and humidity and rapid stability.

$ 8545.00

Adopt 7.0 inch Touchscreen controller, support 100 programs and 1000 cycles; high temperature and humidity control accuracy, temperature fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier and French Taikang Compressor to ensure stable and reliable testing.

$ 7222.00

Temperature range -30~ 150 ℃, humidity control 30~ 98% R.H., using PID control mode to ensure small temperature and humidity fluctuations, equipped with independent over-temperature protector and multi-layer sealing structure to improve test reliability and safety.

$ 12579.00

Conductivity Detector principle and temperature and humidity compensation technology, measurement accuracy of +/- 0.5%, Response Time of 1 second, integrated design supports on-site rapid detection, suitable for a variety of grain moisture measurement.

$ 112.00

Using French Taikang fully enclosed Compressor, temperature and humidity control accuracy of +/- 0.1 ℃ and +/- 1% R.H., equipped with multi-wing air supply circulation system to ensure uniform temperature and humidity distribution in the test area and improve test efficiency.

$ 11482.00

With -60~ 150 ℃ wide temperature control and 30~ 98% RH humidity range, using French Taikang Compressor and multi-wing air supply circulation to ensure uniform distribution of temperature and humidity and improve test reliability.

$ 10401.00

Humidity Control Range 80~ 95% RH, Temperature resolution 0.1 ℃, Humidity deviation +/- 3% RH, Mirror stainless steel liner easy to clean, independent temperature limit alarm system to ensure safety.

$ 1953.00

The mirror stainless steel liner is easy to clean, the TMHM equilibrating conditioning method controls temperature and humidity accurately, Temperature Fluctuation +/- 0.5 ℃, Humidity deviation +/- 3% RH, with independent temperature limit alarm system.

$ 5110.00

Articles

Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Effect of Rapid Temperature Change Aging Chamber on Thermal Cycling of Composite Materials
This article primarily explores how rapid thermal cycling chambers affect the performance of composite materials during thermal cycling. It explains that thermal cycling can induce internal stresses in composite materials due to differences in the thermal expansion coefficients of their components, potentially leading to microcracks or performance degradation.
Constant Temperature and Humidity Aging Chamber for Testing Hygrothermal Aging Performance of Composite Materials
This article introduces how to use a constant temperature and humidity aging chamber to test the hygrothermal aging performance of composite materials. Hygrothermal aging refers to the gradual decline in material performance under the combined effects of temperature and humidity.
Constant Temperature and Humidity Chamber for Testing Packaging Moisture and Heat Resistance
This article introduces the method of using a constant temperature and humidity test chamber to test the resistance of packaging to heat and humidity. The test chamber simulates hot and humid environments by controlling temperature and humidity, thereby evaluating the performance changes of packaging materials.
Humidity and heat test chamber tests the moisture absorption rate of resin under high temperature and high humidity conditions.
This article introduces the method of using a hygrothermal test chamber to measure the moisture absorption rate of resin under high temperature and high humidity conditions.
Humidity and Heat Test Chamber for Evaluating Coating Performance under High Temperature and High Humidity Conditions
This article introduces how a humidity and heat test chamber is used to evaluate the performance of coatings in high-temperature and high-humidity environments. Coatings are widely used in industries such as automotive and electronics, but they are prone to issues like reduced adhesion and blistering under actual high-temperature and high-humidity conditions.
How to Choose the Heating and Cooling Rate for a Rapid Temperature Change Test Chamber
When selecting the heating and cooling rates for a rapid temperature change test chamber, it is essential to comprehensively consider the test standards, product characteristics, and actual engineering requirements. Rates that are too high or too low may affect the test results, making it difficult to accurately evaluate the product's environmental tolerance.
Application of Damp Heat Testing in the Environmental Adaptability Verification of Automotive Components
Humidity and heat testing is an accelerated test method that simulates high-temperature and high-humidity environments, used to evaluate the performance changes of automotive components under humid conditions. It primarily examines the insulation and corrosion resistance capabilities of electrical and electronic components, the aging resistance of interior materials, and the corrosion prevention effectiveness of exterior structural parts.
Differences and Selection Between Alternating Damp Heat and Constant Damp Heat Test Methods
Based on the patterns of humidity and temperature changes, they are mainly divided into two categories: constant damp heat tests and cyclic damp heat tests. Both simulate the effects of humid environments on products, but there are significant differences in their stress application methods, failure mechanisms, and applicable standards.