Photoelectric Integral ColoriMeter

The photoelectric integrating colorimeter illuminates the sample with a built-in light source, and the sensor receives the reflected light and converts it into an electrical signal. The processor then integrates and calculates color parameters. It is used to measure the surface color data of objects and control color consistency in industries such as coatings and plastics.
Selection
When selecting, consider matching the measurement aperture to the sample size, ensuring instrument repeatability meets production tolerances, and verifying compliance with industry standards. Pay attention to the instrument's long-term stability, ease of operation, maintenance costs, and the manufacturer's technical support capabilities.

Terms

Instruments

Using parallel illumination hemispherical scattering integrating sphere photoelectric receiving mode, the accuracy of light transmitance and haze display is 0.01%, equipped with thin film magnetic fixture and liquid sample Cup, and supports 2000 sets of data storage.

$ 3882.00

Using parallel illumination hemisphere scattering integrating sphere photoelectric reception mode, light transmitance measurement range 0-100%, haze measurement range 0-99%, with open sample window design, not affected by environment light.

$ 2629.00

Using parallel illumination hemispherical scattering integrating sphere photoelectric receiving mode, the light transmitter and haze measurement accuracy are 0.01%, support U disk storage and USB communication, equipped with thin film magnetic fixture and liquid sample Cup.

$ 2888.00

Support 20 °/60 °/85 ° three-angle measurement, Measurement range 0~ 200GU, Repeatability +/- 0.5GU, Stability +/- 0.4GU, can store 254 sets of data and have Automatic calibration function.

$ 396.00

Single angle 60 ° measurement, Stability 0.4GU, Repeatability 0.5GU, Automatic calibration without manual operation, can store 254 sets of data, lightweight and portable design.

$ 240.00

Using D/8 structure to fit the human eye observation, built-in High Accuracy Light spectrum Sensor captures 400-700nm wavelength rays of light, quickly converts the light signal into accurate digital color information.

$ 227.00

The integral pump structure is adopted, and the forced oil pump lubrication system ensures stable operation. Ultimate vacuum degree reaches 5x10 ^ Pa, and the noise is only 58dB. The special gas ballast valve can efficiently extract steam without polluting the oil quality.

$ 1437.00

Using 150mm integrating sphere and 25mm test hole, Measurement accuracy Delta R457 ≤ 0.5, support Opacity, transparency and inks absorption value and other Multi-ParaMeter detection, suitable for a variety of sample thicknesses.

$ 2329.00

Using photoelectric detection and automatic dial display, the measurement range is +/- 45 °, the minimum reading is 0.001 °, and the low optical rotation sample can be accurately analyzed, and the operation is simple.

$ 1380.00

Adopt trapezoidal screw drive and integral nut design, rated load 500N, Travel 150mm, can be firmly clamped to prevent partial load, fast loading and unloading to improve measurement accuracy, vertical and horizontal dual-use to adapt to a variety of test scenarios.

$ 332.00

Using photoelectric detection technology to achieve automatic measurement, linear heating rate adjustable eight, Temperature range to 400 ℃, accuracy of +/- 0.5 ℃, in line with pharmacopoeia specifications.

$ 1501.00

Using photoelectric automatic equilibrating principle, measurement range +/- 45 ° optical rotation and +/- 120 ° Z sugar content, minimum reading +/- 0.001 °, equipped with color LCD Touchscreen and USB interface, support automatic retest 6 times and calculate the average value.

$ 1752.00

High Accuracy photoelectric induction switch and precision screw drive, the load can be stacked 500/750/1000g, the test angle is 45 °, the operation is accurate and stable, in line with a variety of international standards.

$ 929.00

With photoelectric detection and automatic measurement function, Temperature range RT +~ 320 ℃, resolution 0.01 ℃, eight linear heating rate optional, support melting Linear dispersion recording and average calculation.

$ 1501.00

With photoelectric detection and eight linear heating rate, Temperature range RT +~ 400 ℃, accuracy +/- 0.2 ℃, automatic recording of molten Linear dispersion and calculation of average value, no manual monitoring.

$ 1648.00

Articles

Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
The combination of hiding power chart paper and a spectrophotometer enables the digital evaluation of hiding power.
This article introduces how to combine hiding power cards with spectrophotometers to achieve digital assessment of hiding power.
Colorimeter evaluation of color difference in anodized coloring layers
This article explains how colorimeters are used to evaluate color differences in anodized coloring layers. It describes how colorimeters convert colors into numerical values based on international standards and quantify color variations by calculating the color difference ΔE.
A spectrophotometer uses digital language to describe colors, making color differences impossible to hide.
A spectrophotometer measures the color of an object through spectral analysis, converting reflected light data into spectral curves. It then calculates chromaticity parameters such as L*a*b* based on international standards, achieving a digital representation of color.
How to Interpret Color Difference Lab Values Measured by a Spectrophotometer? Save This Color Difference Judgment Standard Now!
This article explains how spectrophotometers measure and evaluate color differences using the Lab color space. In the Lab values, L represents lightness, while a and b indicate the red-green and yellow-blue color biases. The color difference ΔE is calculated using a formula to quantify the variation between a sample and the standard.