Using parallel illumination hemispherical scattering integrating sphere photoelectric receiving mode, the accuracy of light transmitance and haze display is 0.01%, equipped with thin film magnetic fixture and liquid sample Cup, and supports 2000 sets of data storage.
Using parallel illumination hemisphere scattering integrating sphere photoelectric reception mode, light transmitance measurement range 0-100%, haze measurement range 0-99%, with open sample window design, not affected by environment light.
Using parallel illumination hemispherical scattering integrating sphere photoelectric receiving mode, the light transmitter and haze measurement accuracy are 0.01%, support U disk storage and USB communication, equipped with thin film magnetic fixture and liquid sample Cup.
Support 20 °/60 °/85 ° three-angle measurement, Measurement range 0~ 200GU, Repeatability +/- 0.5GU, Stability +/- 0.4GU, can store 254 sets of data and have Automatic calibration function.
Single angle 60 ° measurement, Stability 0.4GU, Repeatability 0.5GU, Automatic calibration without manual operation, can store 254 sets of data, lightweight and portable design.
Using D/8 structure to fit the human eye observation, built-in High Accuracy Light spectrum Sensor captures 400-700nm wavelength rays of light, quickly converts the light signal into accurate digital color information.
The integral pump structure is adopted, and the forced oil pump lubrication system ensures stable operation. Ultimate vacuum degree reaches 5x10 ^ Pa, and the noise is only 58dB. The special gas ballast valve can efficiently extract steam without polluting the oil quality.
Using 150mm integrating sphere and 25mm test hole, Measurement accuracy Delta R457 ≤ 0.5, support Opacity, transparency and inks absorption value and other Multi-ParaMeter detection, suitable for a variety of sample thicknesses.
Using photoelectric detection and automatic dial display, the measurement range is +/- 45 °, the minimum reading is 0.001 °, and the low optical rotation sample can be accurately analyzed, and the operation is simple.
Adopt trapezoidal screw drive and integral nut design, rated load 500N, Travel 150mm, can be firmly clamped to prevent partial load, fast loading and unloading to improve measurement accuracy, vertical and horizontal dual-use to adapt to a variety of test scenarios.
Using photoelectric detection technology to achieve automatic measurement, linear heating rate adjustable eight, Temperature range to 400 ℃, accuracy of +/- 0.5 ℃, in line with pharmacopoeia specifications.
Using photoelectric automatic equilibrating principle, measurement range +/- 45 ° optical rotation and +/- 120 ° Z sugar content, minimum reading +/- 0.001 °, equipped with color LCD Touchscreen and USB interface, support automatic retest 6 times and calculate the average value.
High Accuracy photoelectric induction switch and precision screw drive, the load can be stacked 500/750/1000g, the test angle is 45 °, the operation is accurate and stable, in line with a variety of international standards.
With photoelectric detection and automatic measurement function, Temperature range RT +~ 320 ℃, resolution 0.01 ℃, eight linear heating rate optional, support melting Linear dispersion recording and average calculation.
With photoelectric detection and eight linear heating rate, Temperature range RT +~ 400 ℃, accuracy +/- 0.2 ℃, automatic recording of molten Linear dispersion and calculation of average value, no manual monitoring.