Adopt digital P.I.D. temperature control, temperature control accuracy +/- 1 ℃, heat sealing pressure 0~ 0.7Mpa adjustable, double cylinder structure to ensure pressure equilibrating, heat sealing knife aluminum alloy material uniform heat conduction, support automatic and manual mode.
Adopt digital P.I.D. temperature control, upper and lower heat seal independent temperature control, heat sealing temperature range RT +~ 300 ℃, heat sealing pressure 0.05~ 0.7MPa, support manual and foot pedal start mode, anti-burn safety design.
Temperature range RT +~ 300 ℃, temperature control accuracy +/- 0.2 ℃, independent temperature control of upper and lower heat sealing heads, good thermal conduction effect of brass heat sealing knife, double-decked thermal insulation design to ensure safe use.
Using sealing high temperature digestion technology, equipped with imported high-luminance Illuminant and PID automatic temperature control system, digestion temperature accuracy of +/- 1.0 ℃, can process 16 water samples at the same time, Optical inspection stability is excellent.
The heat sealing paraMeters are tested by hot pressing sealing method, the temperature control accuracy is up to +/- 0.2 ℃, the heat sealing time is adjustable from 0.1 to 999.9s, and the upper and lower heat sealing heads are supported for independent temperature control and a variety of heat cover customization to ensure accurate and reliable test data.
Adopt sealing high temperature digestion technology, measurement range 0.02~ 10mg/L, Indication Error ≤ +/- 5% FS, equipped with imported high luminance Illuminant and narrow band filter system, support 16 water sample batch processing, Optical inspection stability and good corrosion resistance.
The heat sealing paraMeters were determined by hot-pressing sealing method, the temperature control accuracy was +/- 1 ℃, the heat sealing time was adjustable 0.1-999 s, the upper and lower heat heads were independently controlled, and the double-decked heat insulation design ensured the safety of use.
The heat sealing performance was determined by hot pressing sealing method, the temperature control accuracy was +/- 0.2 ℃, the heat sealing time was 0.1~ 999.9s, the upper and lower heat heads were independently controlled, and the double-decked heat insulation design ensured safety.
Temperature range RT +~ 300 ℃, temperature control accuracy +/- 0.2 ℃, heat sealing time 0.1~ 999.9s adjustable, heat head with brass material to ensure uniform heat conduction, double-decked thermal insulation protection to ensure safe operation.
Using compressed air drive and vacuum generator, equipped with High Accuracy pressure sensor, Vacuum Level range -90~ 0kPa, vacuum accuracy level 1, can be immersion method and expansion method two kinds of sealing performance test.
Glass sealing barrel wall thickness of 15mm, automatic constant pressure gas without manual operation, vacuum accuracy level 1, support 0~ -100kPa range, suitable for a variety of Encasement sealing test.
Using 15mm wall thickness Organic Glass sealing barrel and precision pneumatic components, vacuum accuracy level 1, support 0~ -100kPa range test, with electronic pressure and digital pressure display function.
Vacuum generator to achieve rapid vacuum, accuracy of 1, support 0-9999 seconds holding time automatic control, equipped with imported thickened acrylic sealing barrel, wall thickness 15-20mm, to ensure stable and reliable testing.
The 0-16bar positive pressure method is used to test, which avoids the low pressure limit. The sealing situation can be judged by observing the leakage or pressure drop by inflation and pressure. Sensitivity is high and the reading is accurate.
Adopting 15mm wall thickness high-quality Organic Glass sealing barrel, equipped with automatic constant pressure gas filling function, Vacuum Level range -90~ 0kPa, to achieve automated testing process without manual operation.