The melting temperature error is only +/- 1 ° C, allowing for remote observation of the melting state. It can be directly pasted without complex installation and is suitable for temperature monitoring of a variety of electrical equipment.
The melting temperature error is only +/- 1 ° C, allowing for remote observation of the melting state. It can be directly pasted and used without complicated operation, and is suitable for temperature monitoring of various electrical equipment.
Irreversible discoloration design to ensure permanent preservation of temperature records, 85 ° C accurate temperature measurement point with 2x2cm circular patch, Pressure sensitive adhesive layer to achieve firm paste and its own protective film to enhance durability
Measuring temperature 90 ℃ and the error is only +/- 1 ℃, the melting state can be observed at a distance, directly pasted and used to visually display the overheating of the equipment.
Complete the sterilization of small metal Glass appliances within ten seconds, the maximum temperature is 300 ° C, the temperature control accuracy is +/- 5 ° C, and the built-in over-temperature protection device ensures the safe operation.
The small sample adapter only needs 2-16ml sample volume, temperature accuracy of +/- 0.1 ℃, supports stepless speed measurement and automatic lifting system, with viscosity and temperature correction function and a variety of data storage methods.
With a small sample adapter requiring only 2-16ml sample volume, the SC4 rotor provides accurate viscosity measurement; supports continuously variable speed and +/- 0.1 ° C temperature control accuracy, and electric lift positioning is convenient for cleaning and thermostatic operation.
Using a small amount of sample adapter and SC4 rotor, the sample dosage is only 2-16ml, the viscosity range is 100~ 6.6mPa · s, the temperature accuracy is +/- 0.1 ℃, and it supports continuously variable speed and automatic lifting, shortens the thermostatic time and improves the measurement accuracy.
Adopt 4mm small diaMeter design, suitable for surface or small area measurement; Repeatability Delta E * ab < 0.05 to ensure Measurement accuracy; Horizontal structure is small in size, comfortable and stable to hold.
Rotation speed stable and no temperature rise, Max. stirring Capacity 3L, Speed range 0~ 1500rpm, suitable for small capacity single stirring needs.
Maximum load 0.5KN, designed for small force test, compact structure, easy operation, ensure test Stability and Repeatability.
Support 10-20mL small sample testing, viscosity range 80-40000000mPa · s, equipped with a dedicated rotor for High Accuracy measurement, Thermostatic Bath connection can control the sample temperature.
Using swirl/spin design, light weight and easy to move, can effectively improve the Measurement accuracy and prevent the instrument from falling, suitable for small workpiece measurement scenarios.
Impact energy 2.7mJ, Impact device mass 75g, small damage to the measured surface, does not damage the hardened layer, suitable for measurement of small and thin parts, the minimum thickness of the specimen is 1mm, and the minimum depth of the hardened layer is 0.2mm.
Maximum load 0.5KN, compact structure, reliable clamping, suitable for a variety of small sample testing, easy to operate.