Quantitative Standard Sampler

The quantitative standard sampler controls the sampling area and depth through a mechanical structure to ensure consistent sample quantities. It is used for standardized sampling of materials such as coatings and paper, ensuring the comparability of subsequent test results.

Instruments

The sampling area is 100mm ² and the error is controlled within +/- 0.35cm ², which can handle 0.1~ 1.2mm Film thickness materials. The circular sampling design is used to ensure the standard of the sample, and the operation is simple and the results are reliable.

$ 417.00

The special No. 10 steel knife edge is used to ensure durability, the punching sample is smooth without burrs, the integrated casting structure is sturdy and not deformed, the sampling area is 100cm2, and the sampling Film thickness range is 0.01-1 mm.

$ 551.00

Special No. 10 steel high temperature quenching knife edge, smooth cutting without burrs; one-piece casting structure is sturdy and durable; sampling area 100cm ², error +/- 0.35cm ², suitable for 0.1~ 1.2mm Film thickness material.

$ 551.00

Sampling diaMeter 112.8mm, Film thickness range 0.1-1 mm, can accurately cut 100cm ² standard samples, suitable for paper physical performance testing requirements.

$ 493.00

The sampling area is 100cm ², the error is controlled within +/- 0.35cm ², and the material with 0.1-0 thickness can be processed. Special design is used to ensure accurate and fast sampling.

$ 620.00

Can cut 100cm ² standard area sample, sampling error +/- 0.35cm ², suitable for a variety of sheet material sampling, thickness range 0.1-5 mm, Operating temperature 20 +/- 10 ℃.

$ 933.00

The sampling area is 100cm ², the sampling thickness range is 0.1-1 mm, and the sampling error is +/- 0.35cm ². It is suitable for paper Basis Weight determination and sheet burst resistance test standard sample sampling.

$ 533.00

Simultaneous sampling ECT (100 * 25) mm and PAT (80 * 25) mm two sizes, sampling error +/- 0.5mm, thickness range ≤ 10mm, easy to operate.

$ 453.00

The sampling area is 100cm ², the sampling error is +/- 0.35cm ², the sampling thickness range is 0.1-3 mm, and the special treatment die blade is durable and free of replacement.

$ 595.00

The linear guide is used to ensure smooth and fast sampling, and the imported tungsten sheet is cut without burrs and durable. It supports 18mm thickness sampling, and can cut 25 × 100mm and 25 × 80mm samples.

$ 314.00

It can quickly and accurately cut the standard sample with a diaMeter of 125mm, and the sampling thickness range is 0.1-0. It is suitable for the determination of paper Water Absorbency and is a special tool for the preparation of laboratory standard samples.

$ 688.00

Precision combination of cutting edge to ensure that the sample edge flat, especially for ring pressure test design, can cut standard samples, easy to operate, cutting effect is good.

$ 378.00

Sampling area 100cm ² and error +/- 0.35cm ², removable knife edge sharp handle, with anti-cutting hand protection device, can handle Paper thickness 0.1~ 1.2mm and Corrugated Board 0.1~ 7mm.

$ 391.00

The punching sampling method ensures accuracy, the sampling size error is controlled within 0.1mm, and two specifications of 70 * 38mm stiffness and 36 * 38mm crease stiffness are supported.

$ 525.00

Thrust sampling mode, cutting edge pressure sample 25mmx100mm and gluing sample 25mmx80mm, sampling thickness range of 18mm, suitable for Corrugated Board and carton mass detection.

$ 393.00

Articles

Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Differential Scanning Calorimetry for Measuring the Degree of Cure of Polymer Optical Waveguide Materials
This article introduces a method for determining the degree of curing in polymer optical waveguide materials using a differential scanning calorimeter. The degree of curing is a key indicator affecting material performance, and this instrument quantitatively analyzes it by measuring the thermal effects during the curing reaction.
Quantitative Measurement of Carbon Black Content in Rubber by Thermogravimetric Analyzer
Thermogravimetric analyzers measure changes in sample mass through programmed temperature control, enabling the quantitative determination of carbon black content in rubber. During the experiment, the rubber is first heated in an inert atmosphere to decompose it, leaving the carbon black intact. The atmosphere is then switched to an oxidizing environment to oxidize the carbon black. The carbon black content is calculated based on the mass loss.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Pull-off Adhesion Tester for Quantitative Measurement of Varnish Adhesion.
The pull-off adhesion tester quantitatively measures the adhesion strength between a varnish coating and the substrate by vertically pulling off a test column. It is essential to ensure proper substrate preparation, complete curing of the coating, and the use of a suitable adhesive during testing.
Derivation and Validation of the Quantitative Relationship between Wire Diameter and Wet Film Thickness in Wire Wound Coating Bars
This paper investigates the relationship between the wire diameter in a wire-wound rod coater and the wet film thickness. Theoretically, under ideal conditions, the wet film thickness is approximately half of the wire diameter.
Paper Thickness Gauge for Determining Paper Thickness and Apparent Density
This article explains how to measure paper thickness and apparent density using a paper thickness gauge. Thickness refers to the vertical distance between the two sides of paper under standard pressure, while apparent density is calculated by dividing the basis weight by the thickness, reflecting the compactness of the paper.
Principle and Application of Vacuum Decay Leak Testing Equipment
The vacuum decay leak tester is a non-destructive detection device that quantitatively detects leaks by monitoring minute pressure changes in the test chamber after vacuum evacuation.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
Karl Fischer moisture analyzer detects moisture content in hot melt adhesives.
This article introduces the method of using a Karl Fischer moisture analyzer to detect the moisture content in hot melt adhesives. The Karl Fischer method is based on the quantitative reaction of iodine, sulfur dioxide, and water, and calculates the moisture content by measuring the amount of iodine consumed.
Karl Fischer Moisture Analyzer for Determining Water Content in Coatings
This article introduces the method for determining the water content in coatings using the Karl Fischer moisture analyzer. The principle is based on the quantitative reaction of iodine and sulfur dioxide in the reagent with water. The coulometric method is commonly used to generate iodine through electrolysis and calculate the moisture content by measuring the electrical charge.
Pull-off adhesion tester quantitatively measures bond strength.
The pull-off adhesion tester measures the bonding strength between coatings, linings, and substrates by applying a vertical tensile force.
Atomic Absorption Spectrometer for Determining Heavy Metal Content in Coatings
This article introduces a method for determining the content of heavy metals such as lead, cadmium, chromium, and mercury in coatings using atomic absorption spectroscopy. The method is based on the absorption of characteristic wavelength light by atoms for quantification. It requires acid digestion pretreatment of coating samples and optimization of instrument conditions to improve accuracy.
Principles and Advantages of Ion Chromatography for Determining Anions in Water
Ion chromatography separates anions in water samples through an ion exchange column, then reduces background conductivity and enhances signals via a suppressor, and finally measures and quantifies them using a conductivity detector.
Karl Fischer Moisture Titrator for Determining Solvent Moisture
The Karl Fischer moisture meter determines solvent moisture based on the quantitative reaction of iodine and sulfur dioxide with water in an alkaline environment.