Large Constant Temperature and Humidity Test Chamber

Large constant temperature and humidity test chambers precisely control the temperature and humidity environment within an enclosed space through heating, cooling, humidification, and dehumidification systems. They are used to simulate the tolerance of products under various climatic conditions and are widely applied in material aging tests, electronic component stability verification, and industrial product quality inspections.
Selection
When selecting, consider the matching of the test space dimensions with the sample volume. The temperature and humidity range should cover the actual usage environment, and the control accuracy must meet the requirements of the testing standards. The equipment materials should be corrosion-resistant, while also paying attention to energy consumption indicators and the convenience of after-sales maintenance.

Terms

Instruments

The 7.0-inch large screen is easy to operate, equipped with a French Taikang Compressor unit, Temperature Fluctuation ≤ +/- 0.5 ° C, humidity deviation + 2, -3% R.H, independent temperature and humidity system to improve efficiency.

$ 4027.00

The 7.0-inch large screen is easy to operate, equipped with French Taikang fully enclosed Compressor and multi-wing air supply circulation, Temperature Uniformity ≤ +/- 2 ℃, humidity deviation + 2, -3% RH, support 0~ 9999 minutes timing and independent temperature limit alarm.

$ 7980.00

Using French Taikang Compressor and multi-wing air supply circulation, Temperature Uniformity ≤ +/- 2 ℃, humidity deviation + 2-3% R.H, with independent temperature limit alarm and double-decked Glass observation window to ensure safe and reliable testing.

$ 6367.00

The 7.0-inch large screen is easy to operate, equipped with a French Taikang fully enclosed Compressor unit, Temperature Uniformity ≤ +/- 2 ° C, humidity deviation + 2, -3% R.H, independent temperature limit alarm system to ensure experimental safety.

$ 3494.00

With -60~ 150 ℃ wide temperature range and 30~ 98% RH humidity control, multi-wing air supply cycle to ensure uniform temperature and humidity, 7.0 inch large screen programmable controller supports 100 sets of programs to improve test efficiency and accuracy.

$ 8142.00

Adopt 7.0 inch large screen controller, temperature control accuracy +/- 0.1 ℃, humidity control accuracy +/- 1% R.H., equipped with independent temperature limit alarm system, support multi-wing air supply cycle to ensure uniform temperature.

$ 6157.00

Temperature range -10~ 100 ℃, humidity control 35~ 95% RH, with independent temperature limit alarm system and multi-stage programmable PID controller to ensure safe operation and precise control of temperature and Humidity.

$ 3078.00

Humidity Control Range 80~ 95% RH, Temperature resolution 0.1 ℃, Humidity deviation +/- 3% RH, Mirror stainless steel liner easy to clean, independent temperature limit alarm system to ensure safety.

$ 1953.00

Adopt mirror stainless steel liner and PID Control mode, Temperature range 0~ 60 ℃, Humidity deviation +/- 5~ 8% R.H., 99 cycle programs and independent temperature limit alarm system.

$ 1414.00

The French Taikang Compressor unit is used to ensure stable cooling, the 7-inch large screen realizes simple programming and monitoring, Temperature Uniformity +/- 2 ℃ and humidity deviation is small, and the independent temperature limit alarm system improves the experimental safety.

$ 7625.00

The mirror stainless steel liner is easy to clean, the TMHM equilibrating conditioning method controls temperature and humidity accurately, Temperature Fluctuation +/- 0.5 ℃, Humidity deviation +/- 3% RH, with independent temperature limit alarm system.

$ 5110.00

Temperature range -10~ 100 ℃, Temperature resolution 0.1 ℃, using programmable PID controller and TMHM equilibrating Conditioning method, temperature and humidity control accurate fluctuation is small, with independent temperature limit alarm system and a variety of Safety protection functions.

$ 7871.00

Temperature range 10~ 85 ℃, humidity control 80~ 95% RH, fluorine-free environmental protection design, with independent temperature limit alarm system, mirror stainless steel liner easy to clean, Temperature resolution 0.1 ℃, stable and reliable operation.

$ 1627.00

Imported Humidity Sensor and Compressor, temperature control accuracy of +/- 0.5 ℃, humidity deviation +/- 3% RH, equipped with independent temperature limit alarm system and test hole to ensure the safety and reliability of the experiment.

$ 4122.00

Temperature range -40~ 100 ℃, humidity control 35~ 95% RH, fluorine-free design, imported stainless steel liner, support multi-stage programming and remote communication, ensure uniform and stable insulation Humidity.

$ 5307.00

Articles

Constant temperature and humidity aging chamber for testing plastic yellowing according to GB/T 16422.3.
This article introduces the method of testing plastic yellowing using a constant temperature and humidity aging chamber in accordance with the GB/T 16422.3 standard. Yellowing is an indication of chemical degradation in plastics caused by heat, oxygen, and humidity.
Constant Temperature and Humidity Aging Chamber for Testing Hygrothermal Aging Performance of Composite Materials
This article introduces how to use a constant temperature and humidity aging chamber to test the hygrothermal aging performance of composite materials. Hygrothermal aging refers to the gradual decline in material performance under the combined effects of temperature and humidity.
Constant Temperature and Humidity Chamber for Testing Packaging Moisture and Heat Resistance
This article introduces the method of using a constant temperature and humidity test chamber to test the resistance of packaging to heat and humidity. The test chamber simulates hot and humid environments by controlling temperature and humidity, thereby evaluating the performance changes of packaging materials.
Constant Temperature and Humidity Chamber Testing for Environmental Adaptability of Hot Melt Adhesive
This article introduces the method of testing the environmental adaptability of hot melt adhesive using a constant temperature and humidity chamber. The performance of hot melt adhesive is easily affected by temperature and humidity, and the purpose of the test is to evaluate its stability under different climatic conditions.
Constant Temperature and Humidity Chamber Testing for Ink Environmental Adaptability
This article introduces the method of testing the environmental adaptability of ink using a constant temperature and humidity chamber. Ink is prone to issues such as adhesion, discoloration, or reduced adhesion when exposed to changes in temperature and humidity.
The difference between thermal shock test chambers and constant temperature and humidity chambers
This article compares the differences between thermal shock test chambers and constant temperature and humidity chambers in terms of working principles, key performance, and applications.
Application of Constant Temperature and Humidity Chambers in the Electronics Industry
A constant temperature and humidity chamber is a device capable of precisely controlling temperature and humidity, used to simulate various environmental conditions that electronic products may encounter. In the electronics industry, it is primarily employed to test the reliability of components, finished products, and processes, such as evaluating material aging or performance changes through high-temperature and high-humidity tests.
Common Operational Fault Analysis and Daily Maintenance Strategies for Constant Temperature and Humidity Test Chambers
This paper focuses on typical issues faced by constant temperature and humidity test chambers in practical applications, such as temperature deviations, abnormal humidity control, and blockages in the water circuit system. It delves into the underlying causes of these faults and proposes a maintenance framework centered on daily inspections and standardized operations.
Comparison of Humidity Control Methods in Constant Temperature and Humidity Test Chambers: Wet and Dry Bulb Method vs. Electronic Sensor Method
This article will explain the principles, advantages, and disadvantages of these two methods to help you make a more informed decision when selecting equipment.
Technical Selection and Application of Constant Temperature and Humidity Chambers
This article primarily discusses how to select and use a constant temperature and humidity chamber. It is mainly used to test the performance of materials and products under varying temperature and humidity conditions.