Suitable for reflection color measurement of high concentration liquids, sauces and powder samples, the Cuvette bracket design ensures that the measurement environment is completely black to ensure the accuracy and Stability of measurement results.
Volume 12 liters, the concentration of 5% -35%, equipped with manual speed regulation and digital Rotation speed display function, stainless steel material and new sealing technology to prevent leakage.
Measurement range 0.23 nm g/L to 23 g/L, temperature compensation 5~ 50 ℃, suitable for high purity water and industrial drainage sodium ion concentration determination, repeatability error does not exceed 0.03pNa.
Adopt independent ozone concentration controller for long-term stable non-drift, equipped with high voltage silent discharge tube ozone generator, concentration range 10~ 1000pphm, Temperature Fluctuation +/- 0.5 ℃, support static tensile specimen and sample rack speed 1~ 2rpm.
Using 6.44ppt high concentration calibrated liquid, Encasement alone to ensure freshness, light block Encasement anti-ultraviolet oxidation, valid period of up to 5 years, suitable for field and portable use.
Colorimetric measurement using Nessler method. Measurement range is 0.0~ 100.0 ppm ammonium. 100 tests are provided. Yellow shade is generated for concentration determination.
Maxwell turbidity unit measurement of bacterial concentration, resolution 0.001 MCF, range 0-6MCF, with High Accuracy optical path system and low drift circuit, can store 20 records to ensure measurement accuracy and Repeatability.
Colorimetric measurement using ferrous sulfate method, Measurement range 0~ 150mg/L, providing 100 tests to ensure accurate determination of nitrite concentration.
Colorimetric measurements using the Nessler method are fast. Measurement range is 0.0 to 100.0 mg/L, providing 300 tests, ensuring accurate determination of ammonium Ion concentration and supporting unit conversion.
Measurement range 0.0~ 12.5 ppm, accuracy +/- 0.1 ppm +/- 5% of reading, fast and easy Ion concentration detection based on DPD method.
Measurement range 6.35μg/L to 63.5mg/L, resolution up to 0.01 pCu, support pCu and concentration conversion, easy operation and high Stability.
Heating power 800W, speed range 0-2600 rpm, support vacuum reaction and pressure reaction for a long time stirring, with durable magnetic steel and PTFE stirrer.
The diazotization method is used to react with nitrite to generate pink color. Measurement range is 0~ 600μg/L, and 100 tests are provided. It is suitable for a variety of Photometers to ensure accurate and reliable concentration determination.
Using LED @575nm Illuminant and Nessler Measuring method, Measurement range 0.00-3 ppm, accuracy +/- 0.03ppm, suitable for low concentration ammonia nitrogen rapid detection, easy and economical operation.
Measurement range 0-999 ppb with accuracy +/- 20 ppb +/- 5% for rapid iron concentration detection.