Hydrogen Sulfide Detection Analyzer

Hydrogen sulfide detection analyzers measure gas concentrations through electrochemical sensors or optical principles. When hydrogen sulfide reacts with the sensing element, it generates an electrical signal or changes in light intensity, which the instrument then converts into a concentration reading. These analyzers are used for leak monitoring and ensuring safety in work environments, such as chemical plants and wastewater treatment facilities.
Selection
When selecting, focus on ensuring the detection range covers the concentration levels of the application scenarios. Electrochemical sensors are suitable for routine detection, while optical principles are better suited for high-concentration environments. Confirm that the instrument's explosion-proof rating matches the hazardous area classification on-site. Check that the response time and calibration cycle meet the usage requirements. Consider whether the data logging functionality and alarm methods are suitable for on-site management.

Terms

Standards

Instruments

Electrochemical sensors imported, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with intrinsically safe circuit design and explosion-proof certification, support a variety of signal output and remote monitoring functions.

$ 296.00

Electrochemical sensors imported, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with explosion-proof certification and a variety of signal output interfaces, support remote monitoring and automatic Zero tracking, suitable for hazardous environments.

$ 682.00

Supports simultaneous detection of 4 gases and integrated temperature Humidity monitoring, adopts dual temperature Humidity compensation design, has Internet of Things remote monitoring function, Protection Rating up to IP66, Operating temperature range -40~ 55 ℃.

$ 301.00

Electrochemical sensor technology, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with intrinsically safe circuit design and explosion-proof certification, support a variety of signal output interfaces, automatic tracking zero point to prevent drift, adapt to -30~ 50 ℃ working environment.

$ 361.00

Electrochemical sensor principle, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with Intrinsic Safety (IS) design and automatic Zero tracking function, support a variety of signal output and remote monitoring.

$ 361.00

Electrochemical sensors imported, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with intrinsically safe circuit design and explosion-proof certification, support a variety of signal output and remote monitoring, strong anti-interference ability.

$ 682.00

Imported Electrochemical sensor, detection accuracy +/- 2% F. S, Response Time less than 10 seconds. With intrinsically safe circuit design and explosion-proof certification, support RS485 and 4-20mA dual signal output, automatic Zero tracking and temperature compensation functions to ensure long-term Stability.

$ 296.00

Adopt MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds, support 4-20mA/RS485/switch output, can be operated by remote control without opening the lid, with local sound and light alarm and remote monitoring capabilities.

$ 202.00

MCU chip to achieve low power consumption operation, equipped with intelligent Sensor to ensure detection accuracy +/- 3% F. S, support 4-20mA, RS485 and wireless signal output, with explosion-proof structure and remote control operation function.

$ 525.00

Can simultaneously detect four gases, Electrochemical sensor, Response Time instant, alarm sound up to 80 decibels, operation temperature range -10~ 50 ℃, portable design weighs only 360 grams.

$ 241.00

Using Industrial Sensor, Response Time T90 is less than 60 seconds, with waterproof, dustproof and explosion-proof characteristics, the shell is made of high-strength engineering plastic coated with composite anti-skid rubber, natural diffusion detection, Operating temperature range -10~ 55 ℃.

$ 170.00

The device supports simultaneous detection of 4 gases and integrates temperature and Humidity monitoring, adopts physical + software double repetition Humidity compensation, Response Time T90 ≤ national standard, has a variety of wireless communication options and remote paraMeter configuration functions, and is suitable for complex industrial environments.

$ 716.00

It can simultaneously detect four gases and integrate temperature and humidity monitoring, using dual temperature and humidity compensation technology, with a 10-Meter visual distance color screen, and supports a variety of wireless communication and remote configuration functions.

$ 415.00

Pump sampling to ensure stable air flow, faster detection speed; can store 100,000 data and support computer connection printing; Battery capacity 2800mAh, battery life of 10-60 hours; with high and low alarm and automatic diagnosis function.

$ 277.00

Electrochemical sensor, high detection accuracy, Response Time less than 60 seconds. With IP65 waterproof level, support vibration, sound and light triple alarm, built-in 1500mAh lithium battery can work continuously for more than 8 hours.

$ 145.00