Infrared Sulfur Content Analyzer

The infrared sulfur content analyzer determines sulfur content by burning the sample to produce sulfur dioxide and measuring its absorption of specific infrared wavelengths. It is used for quantitative analysis of sulfur elements in products such as petroleum and chemical raw materials, with applications in environmental monitoring and product quality control.
Selection
When selecting, consider that the detection range must cover the sulfur content of the sample, the precision should meet standard requirements, and an anti-interference module should be equipped to handle complex samples. Pay attention to the long-term stability of the instrument, choose compatible sample pretreatment devices, and verify compliance with industry testing standards.

Terms

Standards

Instruments

Using Infrared NDIR Detection Principle, Range 0-100ppm, Response Time ≤ 30S, Flameproof Structure and Various Signal Outputs, Support Remote Monitoring and Intelligent Sensor Technology, Ensure High Accuracy and Stability.

$ 590.00

Low-frequency signal penetration depth of 20mm, can simultaneously measure concrete carbide moisture content and plaster moisture content, built-in environment Sensor, support a variety of professional probe expansion measurement function.

$ 1397.00

4 groups of samples can be tested at the same time, using PID precise temperature control technology, Temperature range from room temperature to 1000 ℃, with automatic calculation of carbon black content and ash content function, open lid structure heat dissipation effect is better.

$ 6205.00

Using electrochemistry principle to detect 0-100ppm sulfur dioxide, with 4G/WIFI wireless communication, IP66 Protection Rating, four Alarm modes and 12-55 hours battery life, support remote paraMeter configuration and temperature compensation algorithm.

$ 588.00

8Mm thick PVC reinforced rigid plastic plate box, sulfur dioxide concentration adjustment range of 600~ 10000ppm, equipped with corrosion-resistant silicone airway and alkali solution exhaust gas treatment system, temperature control accuracy +/- 0.5 ℃.

$ 15823.00

Measurement range 0-40000W/m ², Light spectrum Response 1000-1700nm, can automatically calculate and display infrared barrier rate, photosensitive aperture 10mm, suitable for performance testing of various Infrared sources and thermal insulation materials.

$ 149.00

Sharp probe measurement without leaving marks, measurement range 6%~ 90%, support wood moisture content and wood humidity equivalent value display, equipped with extended Probe and hammer ElectRode for different depth measurement.

$ 444.00

Designed with flameproof and explosion-proof structure, Response Time is less than 30 seconds, accuracy +/- 3% FS, can detect 0-20ppm sulfur dioxide concentration, support 4-20mA and RS485 signal output, suitable for harsh industrial environments.

$ 251.00

Measurement unit with Baume degree, sugar content accuracy +/- 0.1 ° Baumé, automatic temperature compensation, 1.5 seconds fast display results, only 2 drops of sample, waterproof design for a variety of environments.

$ 567.00

Using computer technology to ensure accurate measurement, the measurement range is 0~ 50%, the resolution is 0.1%, and the moisture content and Ambient Temperature can be measured at the same time.

$ 159.00

4 groups of samples can be tested at the same time, using PID temperature control accuracy of 0.1 ℃, support segmented program heating, one key automatic calculation of carbon black and ash content, open the lid structure heat dissipation fast.

$ 2784.00

The thermal weight loss method is used to measure carbon black content, the operating temperature can reach 990 ° C, and the 7-inch Touchscreen is equipped to realize one-button calculation, support segmented paraMeter setting, and the Furnace body separation design has better heat dissipation.

$ 1848.00

The fat content was determined by Soxhlet extraction principle, the measurement range was 0.5% -60%, and two samples could be processed at the same time.

$ 428.00

It can measure refractive index 1.3000~ 1.7000nD and sugar content 0~ 100% Brix, with accuracy of +/- 0.0002nD and +/- 0.1% Brix, respectively, and supports temperature correction and direct data printout.

$ 1282.00

Using electromagnetic wave scanning technology, high frequency scanning depth 50mm, Measurement range 0-99.9%, Response Time 1 second, no contact can be measured without damage to the internal moisture content of the object.

$ 225.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Xenon lamp aging test chamber for testing coating weatherability.
Xenon lamp aging test chambers accelerate the testing of weather resistance for materials such as coatings in the laboratory by simulating the ultraviolet, visible, and infrared portions of sunlight, while controlling conditions like temperature, humidity, and water spray.
Spectrophotometric Determination of Sulfur Content by Ultraviolet Fluorescence Method
The determination of sulfur content by ultraviolet fluorescence spectrophotometry involves burning the sample to convert sulfur into sulfur dioxide, which is then excited by ultraviolet light to produce fluorescence for detection.
How to Choose the Right Spectrophotometer
When selecting a spectrophotometer, it is essential to start from the actual analytical needs, clearly defining the required wavelength range (ultraviolet, visible, or infrared) and the type of detection. Key evaluations should focus on core specifications of the optical system, such as wavelength accuracy, beam type, and stray light levels.