Fluid outflow Cup

Fluid outflow cups measure the viscosity of a fluid by recording the time it takes for a specific volume to flow out through a small hole at the bottom of the cup. They are used in industries such as coatings and inks for on-site rapid testing of flow performance, offering simple and convenient operation.

Instruments

It adopts aluminum alloy Cup body and stainless steel outflow nozzle structure, the outflow aperture is 6mm, and the outflow time of Newton-type liquid in the viscosity range of 188~ 684cSt can be measured, which meets the test requirements of international standards.

$ 146.00

The outflow aperture is 4mm, the outflow time is 0~ 150s, and the measuring hole is equipped with a switch for easy operation to ensure the accuracy of measurement and meet the GB/T1723 standard.

$ 125.00

Adopt aluminum alloy Cup body and stainless steel outflow nozzle, aperture 8mm, viscosity measurement range 600~ 2000cSt, outflow time 30~ 100s, in line with ISO and GB standards.

$ 151.00

3Mm flow hole design, measurement of 7~ 42cSt viscosity range, suitable for Newton type liquid outflow time test, the Cup body is light and durable.

$ 170.00

The bottom hole and tip design are adopted, and the outflow time is determined by observing the appearance of the tip, which realizes rapid viscosity measurement and is suitable for on-site testing needs.

$ 471.00

Using aluminum alloy Cup body and stainless steel outflow nozzle, aperture 3mm, measurement viscosity range of 7~ 42cSt, in line with international standards to ensure measurement accuracy.

$ 146.00

Adopt aluminum alloy Cup body and stainless steel nozzle structure, the outflow aperture is 2mm, the viscosity measurement range is 15~ 30cSt, which is suitable for low viscosity thin liquid test, and the outflow time is controlled at 25~ 150 seconds.

$ 130.00

6Mm flow hole design, measurement viscosity range 188~ 684cSt, aluminum alloy Cup with stainless steel filter to ensure Test accuracy, suitable for Newton type liquid outflow time measurement.

$ 170.00

7Mm diaMeter outflow hole design, made of stainless steel, can be adapted to DIN viscosity Cup to achieve different test requirements, in line with the approximate DIN53211 standard specification.

$ 150.00

Using anodic oxidation aluminum alloy Cup body and stainless steel nozzle, the outflow aperture is 8mm, and the viscosity measurement range is 1200~ 3000cSt, which is suitable for the pRoduction line to quickly test the sample viscosity, and the outflow time is controlled at 25~ 150 seconds.

$ 135.00

Adopting anodic oxidation aluminum alloy Cup body and stainless steel nozzle, the outflow aperture is 6mm, the viscosity measurement range is 550~ 1500cSt, and the outflow time is 25~ 150 seconds, which is suitable for rapid viscosity testing of pRoduction lines.

$ 135.00

Using stainless steel material, diaMeter 3mm outflow hole design, can freely replace the filter, expand the viscosity Cup test range, suitable for different liquid viscosity measurement needs.

$ 155.00

Adopt aluminum alloy Cup body and stainless steel outflow nozzle, aperture 4mm, viscosity measurement range 34~ 135cSt, in line with international standards to ensure measurement accuracy.

$ 146.00

Applicable to the flow time of not less than 20 seconds viscosity measurement, using aluminum material, capacity 50ml, flow hole diaMeter 5.6mm, can be converted into kinematic viscosity.

$ 167.00

In line with DIN 53211 standard, the outflow time is 25~ 150s, the viscosity range is 15~ 30cSt, and the aluminum alloy Cup body and stainless steel nozzle are used to quickly test low viscosity liquids.

$ 135.00

Articles

Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Rotational Viscometer for Measuring and Controlling the Application Viscosity of Coatings
A rotational viscometer is a commonly used tool for controlling the viscosity of coatings during application, as it measures the torque generated by a rotor rotating in a fluid to calculate viscosity.
Application of Laboratory Coating Machines in the Preparation of Lithium Battery Electrodes
As a key device for achieving uniform coating of active material slurries onto current collectors, the application of laboratory coating machines directly influences the areal density consistency, thickness uniformity, and microstructure formation of electrodes, thereby affecting the energy density, cycle life, and safety of batteries.
The difference between a wire bar coater and a gap-type wet film applicator.
The wire-wound drawdown bar directly quantifies the coating through the gap between wires, making it suitable for thin coating preparation with high precision, particularly for low-viscosity fluids. In contrast, the gap-type wet film applicator indirectly controls film thickness through the groove depth, with the actual coating thickness significantly influenced by material properties, making it more suitable for high-viscosity coatings and thick film preparation.
Types and Selection of Paint Viscosity Cups
As a simple tool for measuring the liquid outflow time, the viscosity cup is mainly categorized into various types such as the Tu-4 cup, ISO cup, Ford cup, and Zahn cup, based on standards from different countries and regions. These cups differ in orifice size, capacity, and the types of fluids they are suitable for.