Oil Flash Point Tester

The oil flash point tester heats the oil sample and introduces an ignition source to detect the minimum flash ignition temperature of the mixture of oil vapor and air. It is used to determine the safety of oil transportation and storage, and to monitor the volatility characteristics of oil products in the petrochemical and power industries.
Selection
When selecting, consider matching the type of oil being tested with the standard method: use a closed-cup tester for light oils and an open-cup tester for heavy oils. Verify that the temperature range covers the expected flash point, and pay attention to the accuracy of the heating rate control. Confirm that the sample cup material is corrosion-resistant and that the ignition method complies with the specifications. Evaluate the instrument's self-check function and data recording methods.

Terms

Standards

Instruments

Using electronic ignition and flash detection module, test process automation, Temperature range RT +~ 400 ℃, Repeatability +/- 4 ℃, with over-temperature protection and anti-dry burning function.

$ 5399.00

Using 7-inch true color Touchscreen and 32-bit microprocessor, Temperature range RT +~ 400 ℃, with automatic atmospheric pressure compensation and over-temperature protection function, the test process is fully automated.

$ 5399.00

Adopt ARM microprocessor and color LCD display, with automatic heating, sweeping, ignition function, Repeatability ≤ 110 ℃ +/- 1 ℃, support atmospheric pressure correction and forced Air-Cooled, easy and reliable operation.

$ 2116.00

Using ARM microprocessor and German technology, the test can be completed with only 1-2ml of trace samples. With automatic heating, sweeping, ignition and printing functions, no external combustible gas is required, and the operation is simple and reliable.

$ 4269.00

Using ARM microprocessor and color liquid crystal display, with automatic heating sweep ignition function, Temperature range 40~ 400 ℃, can store 1000 measurement results, support atmospheric pressure correction and forced Air-Cooled.

$ 2116.00

Adopt pure oil-free design to ensure clean gas, dew point range -40~ -60 ℃, exhaust volume 600L/min, automatic start and stop to reduce energy consumption, no need for special personnel on duty and easy maintenance.

$ 1114.00

Measurement range 50~ 40000FPM, accuracy +/- 0.05% n + 1d, Sampling time 0.3 seconds. With automatic stop flash to extend life, external trigger to achieve automatic pattern tracking, accurate measurement Rotation speed without contact.

$ 344.00

High Accuracy temperature control technology, Temperature range RT +~ 400 ℃, resolution 0.1 ℃, support 0.1~ 20 ℃ stepless heating, high-resolution video observation melting process, no map but can store 400 data.

$ 2607.00

The phase transition process of samples can be detected by visual method, and three samples can be processed simultaneously and the average value can be calculated. Temperature range RT +~ 280 ℃, resolution 0.1 ℃, support 0.5-3 ℃/min four-speed heating rate, suitable for dark sample determination.

$ 1106.00

Automatically detect the drop point and softening point of amorphous polymer compounds, temperature resolution 0.1 ℃, heating rate adjustable eight gears, in line with ASTMD3461-97 standard, easy to operate and strong sense of cleanliness.

$ 1719.00

Adjustment with 5 point buttons, 8 Ion concentration calibrated point selection, Measurement accuracy of +/- 1% FS, automatic temperature compensation to ensure full scale accurate measurement, 500 data storage and GLP compliance.

$ 696.00

Measurement accuracy of 0.5% F.S. with 5 point button calibrating and automatic end point locking, 500 data storage and automatic temperature compensation, suitable for a variety of Ion concentration unit selection.

$ 696.00

With 5 point button Adjustment, Measurement accuracy of 1% F. S, Support automatic temperature compensation and end point locking, can store 500 sets of data and comply with GLP specifications, equipped with USB interface for data transmission.

$ 696.00

With 5 point Adjustment, Measurement accuracy 0.5% F.S., Support automatic temperature compensation and end point locking, can store 500 sets of data and comply with GLP specifications, provide a variety of concentration unit selection.

$ 696.00

Using platinum temperature sensor and digital Optical inspection technology, temperature control accuracy 0.1 ℃, can process 2 samples at the same time, with video recording playback function, support 0.1-10 ℃/min heating rate.

$ 3946.00

Articles

Selection Basis for Closed Cup and Open Cup Flash Point Testers: Paint Flash Point Range and Safety Regulations
This article primarily discusses how to select an appropriate flash point tester based on the flash point range of coatings and safety regulations. The flash point is a crucial indicator for measuring the flammability of coatings, and flash point testers are categorized into closed-cup and open-cup types.
Flash Point Tester Selection: Applicable Scenarios for Closed Cup and Open Cup Methods
This article introduces the differences between the closed-cup method and the open-cup method in flash point testing.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Safety Regulations for Closed Cup and Open Cup Methods for Testing the Flash Point of Coatings.
This article introduces two main testing methods for the flash point of coatings: the closed-cup method and the open-cup method. The flash point refers to the lowest temperature at which the vapor of a coating momentarily ignites upon encountering an open flame, serving as a critical indicator for assessing the risk of fire and explosion.