Electric temperature and humidity Meter

The electronic hygrothermograph measures ambient temperature and humidity using built-in sensors, converting physical quantities into electrical signals for display. It is used to monitor environmental conditions in places such as laboratories and warehouses, providing data references for processes like paint drying and paper storage.
Selection
When selecting, pay attention to the measurement range covering the usage environment, the accuracy meeting monitoring needs, the probe size fitting the measurement space, and consider the dustproof and waterproof rating. Check the calibration certificate and sensor type, and compare response time and long-term stability.

Terms

Standards

Instruments

Humidity controller with dry and wet bulb type or electric kiln type, temperature fluctuation +/- 0.5 ℃, humidity deviation +/- 3% RH; with independent temperature limit alarm, Compressor multiple protection and water shortage protection functions to ensure safe operation.

$ 5307.00

Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier, multi-wing air supply circulation, uniform temperature and humidity distribution, improve test reliability.

$ 6560.00

Microcomputer temperature and humidity controller, Temperature Fluctuation +/- 0.5 ℃, humidity fluctuation +/- 5% RH, with over-temperature protection, independent temperature limit alarm system to ensure safe and stable operation of the experiment.

$ 6691.00

Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Temperature Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H, with multi-wing air supply cycle to ensure uniform distribution, improve test reliability.

$ 11079.00

Temperature range -30~ 150 ℃, humidity control 30~ 98% R.H., using PID control mode to ensure small temperature and humidity fluctuations, equipped with independent over-temperature protector and multi-layer sealing structure to improve test reliability and safety.

$ 12579.00

Adopt 7.0 inch Touchscreen controller, support 100 programs and 1000 cycles; high temperature and humidity control accuracy, temperature fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier and French Taikang Compressor to ensure stable and reliable testing.

$ 7222.00

Adopt wet and dry ball or electric kiln type temperature and Humidity controller to achieve multi-stage programmable control, Temperature Uniformity +/- 2 ℃, equipped with independent temperature limit alarm system and Compressor overheating protection, built-in water Tank can be pulled out to facilitate operation and maintenance.

$ 12466.00

The mirror stainless steel liner is easy to clean, the TMHM equilibrating conditioning method controls temperature and humidity accurately, Temperature Fluctuation +/- 0.5 ℃, Humidity deviation +/- 3% RH, with independent temperature limit alarm system.

$ 5110.00

Temperature range -10~ 100 ℃, humidity control 35~ 95% RH, with independent temperature limit alarm system and multi-stage programmable PID controller to ensure safe operation and precise control of temperature and Humidity.

$ 3078.00

Adopt microcomputer temperature and humidity controller, temperature uniformity +/- 1 ℃, humidity fluctuation +/- 5% RH, equipped with mirror stainless steel liner and observation window, support programmable control and multiple safety protection functions.

$ 4843.00

With -60~ 150 ℃ wide temperature control and 30~ 98% RH humidity range, using French Taikang Compressor and multi-wing air supply circulation to ensure uniform distribution of temperature and humidity and improve test reliability.

$ 10401.00

Using French Taikang fully enclosed Compressor, temperature and humidity control accuracy of +/- 0.1 ℃ and +/- 1% R.H., equipped with multi-wing air supply circulation system to ensure uniform temperature and humidity distribution in the test area and improve test efficiency.

$ 11482.00

Humidity Control Range 80~ 95% RH, Temperature resolution 0.1 ℃, Humidity deviation +/- 3% RH, Mirror stainless steel liner easy to clean, independent temperature limit alarm system to ensure safety.

$ 1953.00

Using French Taikang fully enclosed Compressor, equipped with multi-wing air supply circulation system to ensure uniform distribution of temperature and humidity, Temperature Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2-3% R.H, improve test accuracy and efficiency.

$ 7754.00

Equipped with 7.0 inch Touchscreen controller, temperature and humidity control accuracy of +/- 0.1 ℃ and +/- 1% R.H., using French Taikang Compressor and multi-wing air supply circulation to ensure uniform temperature and humidity distribution in the test area and improve test efficiency.

$ 6560.00

Articles

Resistance Tester Selection: Measurement Methods for Low Resistance and High Resistance
This article introduces the selection method of resistance testers. Based on the range of the measured resistance, low resistance requires the four-wire Kelvin method, using constant current and voltage measurement to eliminate the influence of contact resistance; high resistance uses the voltage method to measure tiny currents, with attention to shielding and leakage prevention.
Application of Perovskite Coater in the Preparation of Intermediate Layers in Tandem Solar Cells
This article introduces the application of perovskite coating machines in the preparation of the intermediate layer of tandem solar cells.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Roll-to-Roll Preparation of Perovskite Coaters for Flexible Perovskite Solar Cells
This article introduces the roll-to-roll fabrication method of flexible perovskite solar cells.
Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium-Ion Battery Separators
This article discusses the application of automatic film coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional manual coating methods often result in uneven coatings, which can adversely affect battery performance.
Automatic coating machines are used for the uniform application of conductive silver paste onto ITO glass.
This article explores the technique of uniformly coating conductive silver paste on ITO glass using an automatic coating machine. By controlling parameters such as coating speed and pressure, the automatic coating machine replaces traditional manual methods, thereby enhancing the consistency and repeatability of the coating process.
Study on the Dispersion Uniformity of Blade Coating Machines in High-Load Electrode Slurry Coating
This article investigates how to optimize the dispersion uniformity of coatings by adjusting process parameters when using a blade coater to handle high-load electrode slurries.
The wire bar coater with heating and vacuum adsorption is used for the preparation of perovskite solar cell layers.
This article introduces a new technique for preparing the light-absorbing layer of perovskite solar cells: a wire-bar coater with heating and vacuum adsorption capabilities.