Iodide Ion Meter

The iodide ion meter detects the concentration of iodide ions in a solution through changes in electrode potential and is used for water quality monitoring and analysis of iodine content in food.
Selection
When selecting, consider matching the measurement range to the sample concentration, ensuring the electrode material is suitable for the detection environment, utilizing calibration functions to guarantee data reliability, and choosing an operation interface that aligns with user habits.

Terms

Instruments

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ion selective ElectRode, can store 1000 sets of data, Measurement accuracy of +/- 1% F. S, suitable for a variety of Ion concentration detection.

$ 864.00

Concentration 1000ppm of copper ion standard solution, PTFE bottle Encasement, capacity 480mL, suitable for daily ion calibrating applications.

$ 135.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ion selective ElectRode, can store 1000 sets of data, Measurement accuracy of +/- 0.5% F. S, suitable for a variety of Ion concentration detection.

$ 864.00

Universal ion standard solution concentration 1000ppm, suitable for daily ion calibrating, PTFE bottle Encasement, capacity 480mL, to ensure calibrating accuracy and Stability.

$ 135.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ElectRode, Measurement accuracy +/- 0.5% F.S., can store 1000 sets of data, suitable for a variety of Ion concentration detection.

$ 864.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ion selective ElectRode, expands memory to store 1000 sets of data, Measurement accuracy of +/- 1% F.S.

$ 864.00

Measurement range of 1~ 2 × 10, using BNC plug design, matching pH and ion Meter, easy operation and fast Response, suitable for accurate Ion concentration detection.

$ 191.00

General ion standard solution with a concentration of 1000ppm, using PTFE solution bottle Encasement, capacity 480mL, suitable for daily ion calibrating needs.

$ 135.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods, automatically recognizes ion selective ElectRode, can store 1000 sets of data, Measurement accuracy of +/- 1% F.S.

$ 864.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods and a variety of concentration units, automatically recognizes ion selective ElectRode, can store 1000 sets of data, Measurement range 5 × 10~ 1M.

$ 864.00

Constant background ion strength, Shielding interfering ions and adjusting sample pH value, capacity 480mL, PTFE bottle Encasement, suitable for a variety of ion measurement environment.

$ 135.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods and 13 optional paraMeters, Measurement accuracy +/- 1% F. S, automatically recognizes ion ElectRode and stores 1000 sets of data, with calibrated reminder and USB Communication interface.

$ 864.00

250Ml Encasement Specification, dedicated to fluoride ion detection, provides a stable ion strength environment, effectively guarantees ElectRode Measurement accuracy and Repeatability.

$ 127.00

Calcium Ion concentration 1000ppm, PTFE solution bottle Encasement, capacity 480mL, suitable for daily ion calibrating, to ensure measurement accuracy.

$ 135.00

Equipped with 7-inch TFT display, supports 5 ion Measuring methods and 2 to 5 point calibrating, automatically recognizes ion selective ElectRode, can store 1000 sets of data, Measurement accuracy of +/- 0.5% F.S.

$ 864.00

Articles

Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
Karl Fischer moisture analyzer detects moisture content in hot melt adhesives.
This article introduces the method of using a Karl Fischer moisture analyzer to detect the moisture content in hot melt adhesives. The Karl Fischer method is based on the quantitative reaction of iodine, sulfur dioxide, and water, and calculates the moisture content by measuring the amount of iodine consumed.
Karl Fischer Moisture Analyzer for Determining Water Content in Coatings
This article introduces the method for determining the water content in coatings using the Karl Fischer moisture analyzer. The principle is based on the quantitative reaction of iodine and sulfur dioxide in the reagent with water. The coulometric method is commonly used to generate iodine through electrolysis and calculate the moisture content by measuring the electrical charge.
Karl Fischer Moisture Titrator for Determining Solvent Moisture
The Karl Fischer moisture meter determines solvent moisture based on the quantitative reaction of iodine and sulfur dioxide with water in an alkaline environment.
Combined Use of Iodine Value and Saponification Value to Assess Oil Quality
In the field of lipid analysis, iodine value and saponification value are two key chemical indicators that reflect the composition characteristics of oils and fats from different perspectives.