Laser Nanoparticle Size Analyzer

The laser nanoparticle size analyzer works by irradiating sample particles with a laser to generate scattered light, and then calculating particle size by analyzing the distribution of scattering angles and intensities. It is used to measure the size distribution of nanoparticles, such as monitoring the particle size of pigments and fillers in industries like coatings and inks.
Selection
When selecting, consider whether the measurement range covers the particle size of the sample to be tested, pay attention to the repeatability and resolution of the instrument, check whether it complies with industry testing standards, evaluate the complexity of the sample preparation process, and confirm that the data output format is compatible with the existing system.
Optical inspection principle
test principle
Special purpose

Terms

Standards

Instruments

Featuring a stainless steel frame suitable for dry, wet, and manual sieving, with a pore size of 250μm, laser engraving provides clear labeling to ensure full traceability.

$ 791.00

The stainless steel frame is suitable for wet and dry screening, laser engraving ensures clear traceability, and the aperture of 100μm meets the needs of fine grading.

$ 805.00

Using laser scattering technology, a single measurement can simultaneously display up to five particle size particulate matter (PM) concentrations, Sensitivity of 0.001 mg/m ³, no need to replace the cutting head, support continuous monitoring and Data storage functions.

$ 4398.00

Featuring a stainless steel frame, suitable for dry, wet, and manual sieving, with a 500 μm aperture, laser-engraved labels provide clear identification and full traceability.

$ 604.00

Using laser scattering technology, one measurement simultaneously displays five particle size data, detection range 0.01-100 mg/m ³, Sensitivity up to 0.01mg/m ³, no need to replace the cutting head, support continuous monitoring and Data storage functions.

$ 4398.00

Adopting stainless steel frame, suitable for dry, wet and manual screening, with a aperture of 150 μm, laser engraved labels ensure clear traceability and meet ISO standards.

$ 604.00

With six-channel particle size detection and 2.83L/min Sampling flow rate, using laser Illuminant life of over 30,000 hours, support UCL calculation and Built-in Printer, AC-DC dual-use can work continuously for more than 6 hours.

$ 848.00

With six-channel particle size detection capability, Sampling flow rate 2.83L/min, using long-life laser Illuminant to ensure Stability, built-in thermal printer and support AC and DC power supply, can work continuously for more than 6 hours.

$ 1171.00

Using laser scattering technology, the detection sensitivity is 0.01mg/m ³, the Measurement range is 0.01~ 100 mg/m ³, with self-cleaning and clean gas Shielding functions, and supports a variety of cutters and timing sampling modes.

$ 2139.00

Using laser scattering technology, Sensitivity up to 0.001mg/m ³, Measurement range 0.001~ 10mg/m ³, with self-cleaning and filter sampling functions, support a variety of cutter options, to achieve rapid continuous monitoring.

$ 2139.00

Laser Sensor is used to directly measure the natural vibration Frequency of the belt. Measurement range is 10Hz~ 800Hz. The size of the split Probe is only 124 * 21 * 12mm. It can penetrate into a small space of 66mm and supports metric and imperial Unit switching.

$ 709.00

Laser Sensor is used to directly measure the natural vibration frequency of the belt. The size of the split probe is only 124 * 21 * 12mm, which can penetrate into the depth of 66mm. Measurement range is 10-500Hz, and it supports metric and imperial unit switching.

$ 627.00

Laser Sensor is used to directly measure the natural vibration frequency of the belt. Measurement range is 10-800Hz. The split probe size is 124 * 21 * 12mm and can penetrate into a small space of 66mm. It supports metric and imperial unit switching.

$ 904.00

Laser Sensor is used to directly measure the natural vibration Frequency of the belt, combined with the input belt mass and free length to calculate the tension, Measurement range 10Hz~ 500Hz, split Sensor size can penetrate into 66mm narrow space, support Metric Imperial Unit switch.

$ 507.00

Using laser light scattering technology, Measurement range 0.01-100 mg/m ³, accuracy of 0.001mg/m ³, with self-calibration system and air curtain Shielding function, support a variety of particle size measurement and continuous monitoring.

$ 2591.00

Articles

Comparison of Selection Parameters for Stylus and Laser Roughness Measuring Instruments
Stylus-type roughness measuring instruments perform contact scanning to measure two-dimensional profile parameters in accordance with standards such as ISO 4287, while laser-based instruments utilize non-contact optical principles and refer to ISO 25178.
Transmittance Meter Selection Guide: Principles for Matching Light Sources and Samples
This article introduces how to select the light source for a transmittance meter based on sample characteristics. The types of light sources include halogen tungsten lamps, LEDs, and lasers, which are suitable for wide-band, monochromatic, or high-precision measurements, respectively.
The coating machine applies a conductive layer (silver nanowires) for flexible display screens onto a PET substrate.
This article introduces the technique of coating a silver nanowire conductive layer on PET substrates using a film applicator. Silver
Laser particle size analyzer measures the particle size distribution of spray powder.
Laser particle size analyzers measure the particle size distribution of sprayed powder based on the principle of light scattering, which is critical for coating uniformity and adhesion. During measurement, the powder must be dispersed in a suitable medium to avoid agglomeration, and tests should be repeated to ensure accuracy.
Operating Specifications for the Determination of Hexavalent Chromium Content in Wastewater Using Colorimetric Titration Apparatus
This article introduces the standard operating procedure for determining hexavalent chromium content in wastewater using a colorimetric titrator. The method is based on the reaction between hexavalent chromium and diphenylcarbazide under acidic conditions to form a purplish-red complex, with the titration endpoint determined by monitoring changes in absorbance at a wavelength of 540 nanometers.
Laser particle size analyzer analyzes particle size distribution of paint pigments.
This article introduces the application of laser particle size analyzers in analyzing the particle size distribution of paint pigments. It mentions that the particle size distribution of pigments affects the optical properties, stability, and rheological characteristics of coatings.
Sieve Residue Analyzer and Sieve Analysis for Determining Pigment Particle Size Distribution
This article introduces how the sieve residue analyzer measures the particle size distribution of pigments through mechanical sieving.
Copper nanowire and zinc oxide thin film preparation coater
The coating machine is a key device for preparing copper nanowires and zinc oxide thin films, which uniformly coats slurry onto a substrate through methods such as blade coating to form a thin film.
Preparation of silver nanowire transparent conductive films by the wire bar coating method
The preparation of silver nanowire transparent conductive films using a coating method is an efficient and scalable production process. This article systematically elaborates on the technology from aspects such as principles, materials, processes, performance characterization, and standards.
How to achieve high uniformity in silver nanowire transparent conductive films through wire rod coating
This article introduces how to prepare uniform silver nanowire transparent conductive films using the wire rod coating technique. These films, which use silver nanowires as the conductive material, exhibit high transparency and conductivity, making them suitable for applications such as touch panels.