The PD array Detector meets the CIE V (lambda) 2 degree Visual Response, the measurement aperture is Φ 15mm, and the open sample compartment supports vertical horizontal testing. Illuminant and environment changes are dynamically monitored to ensure reliable data.
Using laser scattering technology, the detection sensitivity is 0.01mg/m ³, the Measurement range is 0.01~ 100 mg/m ³, with self-cleaning and clean gas Shielding functions, and supports a variety of cutters and timing sampling modes.
Using laser scattering technology, one measurement simultaneously displays five particle size data, detection range 0.01-100 mg/m ³, Sensitivity up to 0.01mg/m ³, no need to replace the cutting head, support continuous monitoring and Data storage functions.
Using laser scattering technology, a single measurement can simultaneously display up to five particle size particulate matter (PM) concentrations, Sensitivity of 0.001 mg/m ³, no need to replace the cutting head, support continuous monitoring and Data storage functions.
With 12 independent control gas paths, each purge needle can be switched on and off separately, temperature control accuracy up to +/- 0.3 ° C, adjustable air cavity height, support for different testtube specifications, built-in over-temperature protection and fault alarm functions.
The laser light scattering principle to achieve rapid measurement, detection sensitivity of 0.001mg/m ³, with online automatic mechanical Adjustment, built-in optical path self-cleaning system to avoid contamination of core components, support a variety of cutter selection.
The width is 3cm, the optical path is 10mm, and the dimensions are 12.5 × 32.5 × 45mm. As a special accessory for Spectrophotometer, it ensures the stability of the optical path and the accuracy of measurement.
Fast measurement using laser light scattering principle, with online automatic mechanical Adjustment, Measurement range 0.01-100 mg/m ³, built-in optical path self-cleaning system to avoid pollution, support a variety of cutters and sampling modes.
PD array Detector and integrating sphere design are used to meet the CIE V (lambda) 2 degree visual Response, the haze Repeatability is within 0.08, and the open sample compartment supports vertical and horizontal dual-mode testing.
It can detect halogen gas leaks of less than 0.5 ounces per year, with an instantaneous Response Time and a Warm-Up Time of less than 90 seconds. It features automatic warm-up and battery protection, and a portable design weighing only 480 grams.
Using laser light scattering method to achieve fast direct reading measurement, Sensitivity of 1 μg/m ³, can detect PM2.5, PM10 and TSP simultaneously, support continuous Measurement mode to store 8000 sets of data, AC and DC dual-use is convenient for portable monitoring.
Using laser scattering technology, Sensitivity up to 0.001mg/m ³, Measurement range 0.001~ 10mg/m ³, with self-cleaning and filter sampling functions, support a variety of cutter options, to achieve rapid continuous monitoring.
Detect NH3 gas, range 0~ 100ppm, resolution 0.1ppm, Response Time T90 ≤ 120s, support sound and light alarm, Operating temperature -10~ 50 ℃, Working time for more than 60 hours, Portable design weighs only 170 grams.
The stainless steel frame is suitable for wet and dry screening, laser engraving ensures clear traceability, and the aperture of 100μm meets the needs of fine grading.
Featuring a stainless steel frame, suitable for dry, wet, and manual sieving, with a 500 μm aperture, laser-engraved labels provide clear identification and full traceability.