Solid Content and Moisture Analyzer

Solid content moisture analyzers heat samples to evaporate moisture and calculate the proportion of solid substances based on weight loss. They are used in the production processes of coatings, inks, and other materials to monitor drying levels and formulation ratios, ensuring product stability.
Selection
When selecting, consider the compatibility of the sample characteristics with the heating method, as thermogravimetric analysis is suitable for most materials; check the measurement accuracy and temperature control range; confirm that the instrument complies with industry testing standards; and evaluate the ease of operation and maintenance costs.

Terms

Standards

Instruments

Low-frequency signal penetration depth of 20mm, can simultaneously measure concrete carbide moisture content and plaster moisture content, built-in environment Sensor, support a variety of professional probe expansion measurement function.

$ 1397.00

Using computer technology to ensure accurate measurement, the measurement range is 0~ 50%, the resolution is 0.1%, and the moisture content and Ambient Temperature can be measured at the same time.

$ 159.00

It can evaporate water in solid samples of 10g or less, use disposable sample bottle sampling, vaporize by heating and transport water in high purity Developing solvent, suitable for a variety of solid or quasi-solid sample analysis.

$ 3462.00

Sharp probe measurement without leaving marks, measurement range 6%~ 90%, support wood moisture content and wood humidity equivalent value display, equipped with extended Probe and hammer ElectRode for different depth measurement.

$ 444.00

Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.

$ 359.00

Using electromagnetic wave scanning technology, high frequency scanning depth 50mm, Measurement range 0-99.9%, Response Time 1 second, no contact can be measured without damage to the internal moisture content of the object.

$ 225.00

Using pyrolysis weight principle design, equipped with halogen heating unit, moisture readability of 0.02%, heating temperature up to 200 ℃, support automatic manual timing test, real-time display Moisture content change process.

$ 441.00

Temperature range RT +~ 180 ℃, the fastest few minutes to complete the measurement. With automatic alarm and Draft Shield design, support moisture and Solid content conversion at the same time, Test accuracy of 0.1%.

$ 420.00

Using halogen lamp heating technology, Capacity 110g, moisture readability 0.02%, with RS232C Communication interface, Heating Temperature range RT +~ 200 ℃, suitable for rapid drying analysis of various samples.

$ 420.00

Using annular halogen lamp heating, Temperature range RT +~ 180 ℃, the fastest few minutes to complete the measurement; Equipped with Draft Shield and imported Sensor, the heating performance is uniform and stable, supporting the simultaneous conversion of water content and solid content.

$ 441.00

Using thermogravimetry principle, moisture readability of 0.01%, equipped with 500W high efficiency halogen lamp and PT100 temperature sensor, heating Temperature range 40-180 ℃, support automatic shutdown and real-time Linear dispersion display.

$ 378.00

Measurement range 0~ 50%, resolution 0.1, can simultaneously measure Moisture content and Ambient Temperature, stylus and host separation design for easy operation, low power LCD display.

$ 140.00

Ring quartz tungsten halogen infrared Heating mode is used to directly heat from the inside of the material, and a unique temperature control system is used to achieve uniform heating. With 0.02% moisture Readability and 50g weighing capacity, real-time monitoring of moisture changes ensures accurate results.

$ 330.00

Using low-frequency signal transmission technology, the measurement depth is up to 20mm, and the humidity distribution map is displayed in real time through Bluetooth connection APP, and the extension Rod can be selected to facilitate large-area measurement.

$ 1009.00

Using pyrolysis weight principle design, moisture readability of 0.01%, heating temperature up to 200 ℃, equipped with 5 inch Touchscreen and German HBM Sensor, support automatic manual timing three test modes.

$ 545.00

Articles

Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
When selecting a laboratory disperser, it is essential to evaluate the dispersion capacity and the speed range.
When selecting a laboratory disperser, it is crucial to evaluate the dispersion capacity and speed range. The dispersion capacity should be determined based on parameters such as material viscosity and solid content to avoid uneven dispersion or localized overheating caused by excessive or insufficient capacity.
Karl Fischer moisture analyzer measures the water content of resin particles.
This article introduces the method of measuring the moisture content of resin pellets using a Karl Fischer moisture meter.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Actual Coating Thickness Deviation of Stainless Steel Wire Rod Coaters at Different Slurry Solid Contents
This article analyzes the actual coating thickness deviation of stainless steel wire rod coaters under different slurry solid contents. The study finds that the solid content of the slurry affects its viscosity and flowability, leading to deviations in the actual coating thickness from the theoretical value.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
Karl Fischer moisture analyzer detects moisture content in hot melt adhesives.
This article introduces the method of using a Karl Fischer moisture analyzer to detect the moisture content in hot melt adhesives. The Karl Fischer method is based on the quantitative reaction of iodine, sulfur dioxide, and water, and calculates the moisture content by measuring the amount of iodine consumed.
Thermogravimetric Analyzer for Determining the Solid Content of Coatings
Thermogravimetric analyzers determine the solid content of coatings by monitoring the change in sample mass with temperature, offering faster and more precise results compared to traditional oven methods.
Karl Fischer Moisture Analyzer for Determining Water Content in Coatings
This article introduces the method for determining the water content in coatings using the Karl Fischer moisture analyzer. The principle is based on the quantitative reaction of iodine and sulfur dioxide in the reagent with water. The coulometric method is commonly used to generate iodine through electrolysis and calculate the moisture content by measuring the electrical charge.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.
Karl Fischer Moisture Titrator for Determining Solvent Moisture
The Karl Fischer moisture meter determines solvent moisture based on the quantitative reaction of iodine and sulfur dioxide with water in an alkaline environment.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.
Difference between halogen moisture analyzer and Karl Fischer moisture analyzer
The core difference between halogen moisture analyzers and Karl Fischer moisture analyzers lies in their measurement principles. Halogen moisture analyzers are based on the thermogravimetric method, while Karl Fischer moisture analyzers rely on titration principles, either volumetric or coulometric, which involve quantitative chemical reactions specifically targeting water molecules.