Pressure-sensitive Adhesive Viscosity Tester

The adhesive viscosity tester measures viscosity by generating torque through the contact between a rotating measurement head and the sample, which is then converted into a viscosity value. It is used to detect the flow characteristics of adhesives and to control coating uniformity and adhesion in the production of labels and tapes.
Selection
Select the appropriate model based on the viscosity range of the sample; match the temperature control module according to temperature regulation requirements; confirm that the rotor specifications are compatible with the sample container; choose a data output method that meets recording needs; verify that the measurement accuracy complies with process standards.

Terms

Standards

Instruments

The pressure-sensitive element is used for automatic counting, the diaMeter of the culture dish supports ≤ Φ 90 mm, and it is equipped with dark deep background and annular fluorescent side-shot lighting. The colony contrast is clear, and the counting is fast and reliable.

$ 228.00

Irreversible discoloration design, temperature accuracy 50 ℃, circular single grid structure, specification 2x2cm, Pressure sensitive adhesive to ensure firm paste, suitable for temperature monitoring in harsh environments.

$ 88.00

The irreversible discoloration feature ensures that the temperature record is permanently preserved, the 75 ° C accurate temperature measurement point is firmly pasted with the Pressure sensitive adhesive, the 2x2cm round design is easy to install and the protective film enhances the durability.

$ 89.00

Measurement accuracy of 0.007mm, Graduation of 0.001mm, probe diaMeter Φ 5mm, maximum measurement depth 45mm, suitable for on-site rapid thickness detection.

$ 251.00

Measurement accuracy of 0.007mm, Graduation of 0.001mm, probe diaMeter of Φ 5mm plane, maximum measurement depth of 80mm, in line with national standards.

$ 267.00

Using irreversible discoloration technology, with three temperature windows, Temperature range 70 ℃ to 120 ℃, Back Pressure sensitive adhesive design is easy to paste, size is 12x30mm.

$ 150.00

Automatic counting using pressure sensitive elements, equipped with special probe pen and dark background lighting, culture dish diaMeter support ≤ Φ 90mm, fast and reliable counting and clear colony contrast.

$ 228.00

With 6 test stations can synchronize multiple sets of tests, High Accuracy proximity switch and laser cross-cut test board, timing range of 9999h59min59s, automatic Timing function to ensure accurate and reliable data.

$ 687.00

Using irreversible discoloration technology, temperature point 60 ℃, specification 2x2cm circular design, with Pressure sensitive adhesive to ensure firm paste, over temperature display red, black and other Color changes.

$ 88.00

Irreversible discoloration design, the temperature window display is clear; three temperature measurement points cover 70 ° C, 85 ° C and 120 ° C; size 12x30mm, 120 pieces each, with Pressure sensitive adhesive for easy sticking.

$ 150.00

Six-station synchronous test, timing accuracy of 99 hours 59 minutes 59 seconds, using imported proximity switch and laser cross-cut test board to ensure accurate and reliable data, with automatic timing and anti-data loss function.

$ 812.00

Irreversible discoloration design, temperature point 80 ℃, specification 2x2cm round, easy to paste with Pressure sensitive adhesive, surface protective film to enhance durability, suitable for harsh Ambient Temperature Monitoring.

$ 88.00

Using irreversible discoloration technology, temperature accuracy up to 120 ℃, circular 2x2cm size with Pressure sensitive adhesive firmly pasted, surface protective film to enhance durability, suitable for harsh Ambient Temperature Monitoring.

$ 89.00

Pressure sensitive adhesive paste, temperature point 70 ℃, specification 2x2cm, irreversible discoloration design, over temperature display a variety of Colors such as red, black, green or yellow, with protective film on the surface, suitable for harsh environments.

$ 88.00

Pressure sensitive adhesive paste firmly, 65 ℃ single point temperature measurement accuracy, irreversible discoloration characteristics can permanently record the overtemperature state, circular design for easy observation, 2x2cm specification suitable for small space installation.

$ 89.00

Articles

How to choose the right rotational viscometer?
This article introduces how to select an appropriate rotational viscometer, so you won't be blind when choosing a viscosity measurement instrument!
How to choose a laboratory coater? Which one should you buy: wire bar, scraper, or slot die?
This article introduces three methods for selecting laboratory coating machines: wire bar coating is suitable for low-viscosity coatings, offering low cost and simple operation; blade coating is ideal for medium-to-high viscosity slurries or those containing particles, with a wide range of film thickness control; slot-die coating provides the highest precision and is suitable for high-end applications such as electronic films.
Laboratory blade coating machine is used for analyzing the film-forming characteristics of high-viscosity slurries.
This article analyzes the characteristics of a laboratory doctor blade coater for forming films from high-viscosity slurries. It focuses on the impact of slurry rheological properties on film formation quality.
Effect of Different Coating Speeds on Film Thickness Consistency in an Adjustable Film Applicator
This paper studies the influence of coating speed of an adjustable film applicator on film thickness uniformity. In the experiment, the coating blade gap was fixed at 100 μm, and a resin solution with a viscosity of 200 mPa·s was used to prepare films at five speeds ranging from 10 to 80 mm/s, followed by thickness measurements.
Stormer viscometer controls the in-can viscosity of latex paint.
This paper introduces the application of the Stormer viscometer in controlling the paint can viscosity of latex paint. Paint can viscosity affects application performance and user experience, with either too high or too low values causing issues.
Rotation rheometer evaluates the atomization performance of water-based paint spraying.
This article introduces how to evaluate the atomization effect of water-based paint spraying using a rotational rheometer. It first explains the two stages of atomization, as well as the importance of rheological parameters such as shear viscosity, storage modulus, loss modulus, and complex viscosity.
Application of Laboratory Scraper Heating Coating Machine in Hot Melt Adhesive Coating
This article introduces the application of a laboratory blade heating coating machine in hot melt adhesive coating. It first explains the coating process and principles, including three stages—heat conduction, fluid shear, and surface wetting—as well as the influence of temperature on adhesive viscosity.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.