Wood pulp cellulose viscoMeter

The wood pulp cellulose viscometer measures viscosity data by rotating a rotor within the sample to gauge the resistance of the cellulose solution to the rotor. It is used in the papermaking industry to monitor pulp fluidity and guide beating processes and paper strength adjustments.
Selection
When selecting, consider that the measurement range should cover the common viscosity values in production, the sample volume should match the laboratory's processing capacity, and the temperature control should align with the process conditions. The calibration certificate must be complete, the rotor material should be corrosion-resistant, and the data interface should facilitate recording and transmission.

Terms

Standards

Instruments

Sharp probe measurement without leaving marks, measurement range 6%~ 90%, support wood moisture content and wood humidity equivalent value display, equipped with extended Probe and hammer ElectRode for different depth measurement.

$ 444.00

Measurement range 0~ 100 ° SR, overflow discharge time 149 +/- 1s, using national standard design, can accurately detect Pulp suspension filtration rate.

$ 1171.00

Measurement range 0~ 100 ° SR, overflow discharge time 149 +/- 1 seconds, cone rising speed 100 +/- 10mm/s, used to detect Pulp suspension filtration rate, in line with ISO 5267-1 international standards.

$ 1340.00

Adopt needle measurement technology, support 150 kinds of wood measurement, measurement range 0~ 80%, accuracy +/- (0.5% n + 0.5), with LCD digital display and LED status indication, provide USB, RS-232 and Bluetooth data interface.

$ 222.00

Measurement principle using resistance method, Measurement range 2~ 70%, accuracy +/- 2%, Response Time only 1 second. With 4 wood Measurement modes, support Data storage and voice reminder function.

$ 94.00

Measurement range 0~ 100 ° SR, cone rising speed 100 +/- 10mm/s, suitable for all kinds of Pulp suspensions, can use raw materials economically and end the Refining process in time, simple and reliable operation.

$ 1106.00

It can measure the range of 0-1000CSF, with an accuracy of 10CSF, using 304 stainless steel material and silicone sealing ring structure, with self-Adjustment, suitable for various Pulp water filtration change detection.

$ 4325.00

Adapt to a variety of Viscometer use, suitable for factory field applications, real-time printing measurement results, no need to hand copy, easy operation, can save labor time.

$ 183.00

Using electronic technology and LCD screen, impeller rotation frequency 49 +/- 1.5S-1, motor power 370W, wet dissociation pulp to maintain the original fiber structure, easy to operate.

$ 1542.00

Made of stainless steel, with a pulp diaMeter of 50mm and a Rod length of 500mm, it is suitable for medium and low viscosity mixing. Medium and high speed operation provides efficient mixing effect.

$ 101.00

The test program can be uploaded to the Viscometer host, the analysis record data can be collected, the rheological Linear dispersion and Excel can be generated, and five sets of data can be plotted and compared at the same time.

$ 204.00

Measurement accuracy of 0.1 ℃, range of 0~ 100 ℃, real-time display of temperature values, suitable for a variety of Viscometer models, to ensure a stable test environment.

$ 135.00

Adopting 1000-5000rpm variable frequency speed regulation technology, equipped with 370W motor and 3L capacity container, it can achieve efficient dissociation without destroying the fiber structure, meeting the processing requirements of different Pulp samples.

$ 2817.00

Silicone oil standard solution, calibrated viscosity 380cp, capacity 400ml, suitable for Viscometer calibrating.

$ 185.00

Using electromagnetic wave scanning technology, measurement depth of 60mm, accuracy +/- 0.5%, Response Time of 1 second, no damage to the surface of the object, support 10 kinds of measurement code selection, automatic temperature compensation.

$ 169.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Comparison of Rotational Viscometer and Capillary Rheometer in Testing the Flowability of Resin Processing
The rotational viscometer measures torque via rotor rotation, making it suitable for testing the static or low-shear fluidity of resins under low shear rates, with simple and quick operation. The capillary rheometer, on the other hand, forces samples through a capillary to simulate high-shear processing, providing flow data closer to actual production conditions, but it is more complex and time-consuming to operate.
Rotational Viscometer Measures Viscosity and Processability of Resin Melts
A rotational viscometer calculates viscosity by measuring the torque experienced by a rotor as it rotates in the resin melt, thereby helping to understand the material's processing properties.
Rotational Viscometer for Measuring and Controlling the Application Viscosity of Coatings
A rotational viscometer is a commonly used tool for controlling the viscosity of coatings during application, as it measures the torque generated by a rotor rotating in a fluid to calculate viscosity.
Method for determining the dynamic viscosity of varnish using a falling ball viscometer
This article introduces a method for measuring the dynamic viscosity of varnish using a falling-ball viscometer. It is based on Stokes' law, which calculates viscosity by measuring the time required for a standard small ball to fall a fixed distance in a vertical glass tube filled with varnish.
Stormer Viscometer for Determining Krebs Viscosity of Paints
This article introduces the method of measuring the Krebs viscosity value of colored paints using a Stormer viscometer. Viscosity is a key indicator that affects the application and storage of coatings. The Krebs unit (KU) quantifies viscosity based on the resistance encountered by a rotor as it rotates within the paint sample.
Rotational viscometer measures the viscosity of paint at low shear rates.
This article introduces the method and significance of measuring the viscosity of colored paint at low shear rates using a rotational viscometer.
Standard Method for Measuring the Melt Viscosity of Hot Melt Adhesives with a Rotational Viscometer
This article introduces the standard method for measuring the molten viscosity of hot-melt adhesives using a rotational viscometer. During the measurement, the hot-melt adhesive sample must be fully melted and degassed, placed into a measuring cup, and then measured with the rotational viscometer at a set temperature.
The cone and plate viscometer measures the rheological properties of a small amount of ink sample.
A cone-plate viscometer measures torque through rotation between the cone and plate, enabling the analysis of rheological properties with small ink samples. It is suitable for small-volume measurements, reducing interference from solvent evaporation.