Measurement range 320~ 685cst, flow hole diaMeter 6mm, Benchtop design with bracket, ISO2431 standard, suitable for viscosity measurement.
Measurement range 35~ 135cst, flow hole diaMeter 4mm, Benchtop design with bracket, in accordance with ISO2431 standard, suitable for viscosity testing.
Integrated Incubator and Shaker functions, Oscillation Frequency 40~ 300rpm, Temperature range RT + 5~ 65 ℃, 304 stainless steel liner and microcomputer PID control, with UV sterilization and automatic storage setting paraMeters.
Measurement range 100~ 300cst, equipped with 5mm flow hole and bracket, using copper Cup body, in line with ISO2431 standard, suitable for Benchtop viscosity testing.
Integrated Incubator and Shaker functions, small footprint and large bottle load; Temperature range 4~ 65 ℃, Temperature Fluctuation +/- 0.2 ℃; 304 stainless steel liner for easy cleaning, quiet operation and support multi-stage programming.
Gas Sleeve Heating mode is used to heat up quickly and evenly, Temperature Fluctuation +/- 0.5 ℃, carbon dioxide concentration recovery time is short, double door design sealing is good for easy observation, Humidity evaporates naturally.
Brass material Benchtop design, flow hole diaMeter 4mm, volume 100ml, in line with GB/T1723 standard, suitable for viscosity below 150s Coating detection, correction factor 0.97~ 1.03.
Integrated Incubator and Shaker functions, small footprint and large bottle capacity; Microcomputer PID control temperature and Oscillation Frequency, Temperature Fluctuation +/- 0.2 ℃; 304 stainless steel liner is easy to clean, supports multi-stage programming and UV sterilization to ensure safe and efficient operation.
The Benchtop structure supports three-station testing, and the control accuracy of the constant rate heating algorithm reaches +/- 0.5 ° C. The data can be automatically recorded and exported to Excel. Transformer oil or methyl silicone oil is used as the heat conduction medium to ensure uniform heat preservation field.
Adopt back heating and horizontal forced convection technology to ensure uniform temperature in the studio; Temperature control accuracy up to 0.1 ° C, Fluctuation +/- 0.5 ° C; Sensor fault alarm and over-temperature protection function, Timer Range 0-9999 minutes.
Measurement range is 0~ 199.9. Opacity of thin sheet material can be measured. Data storage query function is provided. Stability and repRoducibility are high.
Adopt four-link mechanism to ensure a constant 45 ° test angle, equipped with 500/750/1000g adjustable load, accurately determine film Hardness through different Hardness pencil scratches, meeting standard test Environmental requirements.
Adopt rotary multi-dimensional drive structure, smooth operation; Temperature range + 5~ 60 ℃, temperature accuracy +/- 0.1 ℃; With timing function, the operation time can be set arbitrarily, and the operation paraMeter memory function avoids cumbersome operation.
Key parameters include inter-instrument agreement ΔE*ab ≤ 0.25 and chromaticity value repeatability ΔE*ab ≤ 0.02, with features such as automatic aperture recognition, high-definition camera positioning, a damping handle, and four UV measurement modes.
Ultra-thin and lightweight Appearance is only 12mm thick, equipped with 5.5-inch large-screen LCD display, supports three-point or five-point automatic identification and calibrating, Measurement accuracy up to +/- 0.002pH, with GLP management and ElectRode automatic diagnosis function.