Test speed 0-300 times/minute, strike force 0-500gf adjustable, automatically detect key damage and stop within 8 seconds, support multi-pRoduct testing.
Four-station synchronous test to improve efficiency, speed adjustment range of 5-60 times/min, equipped with a conduction counter to automatically stop counting when the button fails, Test Travel 0-60mm adjustable to meet different pRoduct needs.
One key automatic correction ABS value, Wavelength range 190~ 960nm, can be placed 5~ 100mm Cuvette, equipped with RS232 data output interface, support Transmittance, Absorbance, concentration factor and concentration direct reading Operating Mode.
Adopting pneumatic working mode, the test rate can be adjusted from 5 to 60 times per minute, with 4 independent test stations, capable of simultaneously testing switches and plugs and sockets, and supports current on-off and mechanical counting methods.
Ceramic core liquid loop and long life reference system, membrane Impedance is less than 450MΩ, and the shell is made of lead-free Glass to ensure stable measurement and durability.
Ceramic core liquid complex and long life reference system are used, the membrane Impedance is less than 350MΩ, and the shell is made of lead-free Glass, providing stable PH measurement performance.
Using ceramic core liquid complex and long-life reference system, the membrane Impedance is lower than 450MΩ, the PH Measurement range covers 0~ 14pH, and the temperature tolerance is 0~ 100 ℃ to ensure stability and reliability.
With a speed range of 5 to 60 times/minute and 0 to 5cm Travel adjustment, it supports 0 to 99999999 counts and has a delay function. The structure is stable and suitable for connector durability testing.
Electrochemical sensor to detect oxygen, range 0~ 25% VOL, Sensor life up to 5 years, Response Time ≤ 15 seconds, with sound and light alarm and continuous 90 hours of work ability.
Imported 100,000-hour long-life Illuminant and narrowband filter system, Optical inspection stability, measurement range 0-400NTU, resolution up to 0.01NTU, support 10 standard Linear dispersion storage.
With ceramic core liquid complex and long life reference system, the membrane Impedance is less than 450MΩ, supporting 0~ 100 ℃ Temperature range, providing reliable environmental adaptability.
Automatic correction of ABS value with one button, Light spectrum Bandwidth 4nm, Wavelength range 195-1000nm, 5-100mm Cuvette can be placed, Support Transmittance, Absorbance, concentration factor and other Operating Modes.
S-type Glass membrane and PTFE liquid complex structure are used. Impedance of membrane is less than 500MΩ. The reference system is long-life gel electrolysis solution and supports wide temperature environment measurement at 0-80 ℃.
Rapid Response with 130mm Stainless Steel Probe, Temperature Range Coverage -40 to 550 ° C, Accuracy +/- 2 ° C, Battery Error Prevention System to Ensure Measurement Reliability, Up to 700 Hours of Continuous Use.
Using infrared NDIR detection principle, range 0-2% Vol, Response Time ≤ 30 seconds, with flameproof structure and a variety of signal output, support remote monitoring and customized range, Sensor life up to 10 years.