Can be used with A type or C type Shore DuroMeter, fixed load weight mass 0.75 +/- 0.05kg, hardness Gauge clamping Rod connection size M7x0.5mm, improve hardness testing accuracy and Stability.
Supporting D-type Shore DuroMeter, applying 5kg test force by weight, equipped with Glass bench and adjusting nut to ensure full contact with the sample and improve measurement Stability.
Suitable for soft rubber, thermal plasticity resilience and extremely soft plastics, Hardness Measurement range < 20 HDO, with real-time, peak, timing and average Measurement mode, can be connected to the computer for data management and analysis.
Dial design can maintain the maximum Measured value display, Measurement range 0-100 Shore, accuracy up to 1shore, made of wear and corrosion resistant stainless steel aluminum oxide material.
Measurement range < 20O, with MAX Maximum latch, automatic shutdown and data output functions, support USB and Bluetooth communication, error ≤ 1H.
Suitable for materials such as high Hardness rubber and engineering plastics, pressing needle Travel 0~ 2.5mm, Measurement range 0~ 100HD, error +/- 1HD, in line with ASTM D 2240-05 and GB/T2411-2008 standards.
Double pointer design for easy reading, Pin Travel 0~ 2.5mm, Measurement range 0~ 100HD, error +/- 1HD, lightweight and portable only 0.16kg, suitable for on-site Hardness detection.
The hemispherical stylus can measure soft materials below 20DO, with a resolution of 0.1H, supports average calculation and MAX Maximum latch function, and is equipped with a variety of data output interfaces for communication transmission.
Suitable for thin samples with a thickness of less than 6mm, featuring multiple testing modes such as real-time, peak, automatic timing, and average value. It can be connected to a computer for data management and curve analysis.
Measurement range < 20O, resolution 0.1H, support handheld and load rack two measurement methods, with average calculation and a variety of data output interfaces, weight only 310 grams easy to carry.
Digital display design, compact and easy to operate, Measuring accuracy, low power consumption, easy to carry, suitable for field and laboratory rapid Hardness detection.
Adopt R1.2 hemispherical pressure needle, Accuracy ≤ +/- 1H, support multi-unit measurement and automatic shutdown, suitable for soft rubber, thermal plasticity plastic and other materials, Operating temperature 0~ 50 ℃.
Using D type High Accuracy Impact device, Measurement range 30~ 110HS, can detect cast steel roll, forged steel roll and cast iron roll three kinds of hardness of materials, with anti-Impact and anti-electromagnetic interference ability, support 7 kinds of Hardness standard automatic conversion.
Tempered Glass platform, long-term use is not easy to abrasion and rust; the level of the working platform is adjustable, and the hardness Gauge is adjusted to the same level; the weight is accurate, the column lifting space is ≤ 140mm, Dimension 165 * 145 * 380mm.
Resolution 0.1H, Accuracy ≤ 1H, Measurement range 10~ 90 HA/HD; Integrated design is lightweight, supports male/imperial conversion, average calculation and a variety of data output methods.