Vacuum Cooling Circulation Pump

The vacuum cooling circulation pump reduces the boiling point of the liquid through vacuum, allowing the liquid to evaporate and absorb heat at low temperatures to achieve cooling. It is used for circulating cooling in laboratory instruments, maintaining a constant temperature environment and preventing overheating of samples.
Selection
When selecting, consider the pump's vacuum level, cooling temperature range, material corrosion resistance, and flow rate matching equipment requirements. Check the sealing performance, power consumption, and noise indicators, and determine the installation method based on the usage environment and space.

Terms

Standards

Instruments

Two-stage pump structure is equipped with PTFE material pump head, strong corrosion resistance, maximum Flow rate 125L/min, Ultimate vacuum degree 15-20mbar, no pollution and maintenance, low noise and low temperature rise.

$ 3630.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, equipped with multiple Safety protection devices including power-off protection and temperature runaway alarm to ensure the stability and safety of the experimental process.

$ 2241.00

The non-heat centrifugal circulation pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, 4300W cooling capacity to ensure stable operation of the equipment, with multiple Safety protection functions.

$ 2644.00

Using PTFE pump head material and coating diaphragm, suitable for strong corrosive gases, pumping speed 20L/min, Ultimate vacuum degree 3~ 8mbar, with pressure relief and cleaning functions, good air tightness and noise less than 58dB.

$ 1579.00

The use of domestic circulation to ensure uniform and constant temperature, external circulation pump can lead the liquid outside the Tank heating, temperature control accuracy +/- 0.1 ℃, Temperature Fluctuation +/- 1 ℃, LED dual window digital display, insulation layer efficient, Benchtop structure small size.

$ 1080.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway protection to ensure the stable operation of the equipment.

$ 5271.00

Using PTFE pump head and diaphragm material, resistant to strong corrosive gases. Pumping speed 60L/min, Ultimate vacuum degree 3-8mbar, with pressure relief and cleaning functions, good air tightness, operating noise less than 58dB.

$ 2637.00

The built-in vacuum pump realizes 0~ -80kPa Vacuum Level, the fully transparent vacuum Chamber can hold 12 samples, the program control supports 80 sets of paraMeter storage, and the vacuum cycle operation is automatically completed.

$ 4108.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with six safety protections such as low water level protection and temperature runaway protection to ensure the stability and reliability of the experimental process.

$ 4437.00

Using oil-free vacuum pump to achieve pollution-free work, with three-speed Vacuum Level conversion and 0.01s high resolution, intelligent pneumatic pressure to ensure Test accuracy and efficiency.

$ 2612.00

Vacuum chuck area of 300 * 400mm, equipped with 150W vacuum pump, aperture 0.8mm to ensure uniform adsorption, improve Spreader accuracy and Stability.

$ 638.00

Using PTFE pump head material and PTFE coating diaphragm, suitable for strong corrosive gases and steam, pumping speed up to 40L/min, Ultimate vacuum degree 3~ 8mbar, with pressure relief and cleaning functions, noise is less than 58dB.

$ 1785.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, equipped with multiple Safety protection devices including power-off protection and temperature alarm function.

$ 5828.00

Adopt oil pump forced oil inlet device, can operate continuously under 1.33 × 10 ³ Pa intake pressure, gas distribution ballast to prevent pump oil mixing, pumping speed 2L/S, Ultimate vacuum degree up to 0.006mbar, support a variety of interface conversion.

$ 375.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety devices such as low water level protection and temperature runaway protection to ensure the stable operation of the equipment.

$ 1156.00